YZYanli Zhao

Yanli Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yanli Zhao has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of Oleic Acid Composite Vesicles as a Topical Delivery System: An Evaluation of Stability, Skin Permeability, and Antioxidant and Antibacterial Activities

    by Xinyue Ma, Qinqing Zhang, Ying Yang, Yuqi Zhan, Xiangyu Zhang, Yanli Zhao, Jinlian Li, Dongmei Wu

    Fatty acid vesicles (FAVs) are promising nanocarriers, but their application is limited by a narrow, alkaline pH formation window that mismatches the weak acidity of physiological environments, such as skin. To overcome this, we developed composite vesicles using oleic acid (OA) and the non-ionic surfactant Tween 40 (TW40). pH titration confirmed that the OA/TW40 system successfully broadened the vesicle formation window from 8.2–10.08 to 3.1–7.2, aligning it with the physiological pH range. The bioactive flavonoid luteolin (LUT) was efficiently encapsulated into these OA/TW40-FAVs, achieving a high encapsulation efficiency (EE) of 87.13% and a drug loading capacity (DLC) of 9.58. The formulation demonstrated superior topical delivery performance: the cumulative transdermal flux (933.08 µg·cm−2) and skin retention (68.18 µg·cm−2) were both approximately double that of the free LUT solution. Furthermore, the OA/TW40/LUT-FAVs provided sustained drug release and exhibited synergistically enhanced antioxidant and antimicrobial activities compared to free LUT or blank vesicles. Collectively, these findings establish OA/TW40 composite vesicles as a robust and efficient nanoplatform for the topical delivery of bioactive compounds.


  • Open Access

    Study on Electrochemical Behaviors of Heat-Treated Escherichia coli and Staphylococcus aureus

    by Xiaofan Wu, Yupo He, Jiaqi Fu, Yanli Zhao

    Evaluating the bacterial activity effectively is critical to addressing the challenges posed by bacterial infections. Electrochemistry offers significant advantages in accuracy and cost efficiency compared with methods that are more time-consuming or require expensive instrumentation. This study initially established an electrochemical method for detecting bacterial activity using heat treatment as the pretreatment step. Subsequent optimization of the heat treatment and detection conditions further enhanced the method efficiency. The detection results of Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) under different heating conditions showed that the peak current values of E. coli and S. aureus were the highest after heating at 50 °C for 15 min. The dynamic changes in the electrochemical signals from the heat-treated bacteria with alteration in heating conditions were indicated to be related to the effects of heating on the external structure and purine metabolism of the bacterial cells. Although heat-treated E. coli and S. aureus exhibited similar peak potentials, different substances were observed to have contributed to these potentials. A positive linear correlation was observed between the peak current and bacterial concentration. Compared to the plate counting method, the electrochemical method detected the activity changes in E. coli and S. aureus from the logarithmic to the stationary phase earlier. The findings support the broad application of electrochemical methods in microbial detection and provide valuable insights into the purine metabolism of heat-stressed bacteria.


  • Evaluation of the Antibacterial Activity of Antibiotics with different Antibacterial Mechanisms using Electrochemical Signals of Heat‐Treated Escherichia Coli

    by Jiaqi Fu, Jincheng Du, Ting Hou, Zhong Wang, Liyuan Sui, Jinlian Li, Yanli Zhao, Ximing Cui, Dongmei Wu

    Electrochemistry with purines as indicators may be a promising new method for antibiotic activity testing. However, the traditional electrochemical detection method (S‐LSV) requires a long accumulation time for purines and has low signal intensity. High‐temperature treatment of bacterial samples may significantly enhance the signal intensity and speed of detection. However, this process may also impact the structure and metabolism of bacteria. Further research is necessary to determine how electrochemical signals respond to antibiotic antibacterial activity. In this paper, the electrochemical detection method based on heat‐treated Escherichia coli (E. coli, H‐LSV) was used to investigate the effects of 11 antibiotics with four different antibacterial mechanisms on the electrochemical behavior of E. coli. The results showed that compared to the S‐LSV, the electrochemical signal of E. coli detected by the H‐LSV increased by 362%, and showed a strong linear relationship with bacterial counts up to 1.88×108 CFU/mL, with a detection limit of 1.15×106 CFU/mL. The electrochemical signal consistently correlated with changes in viable E. coli counts following treatment with the four different antibacterial mechanisms. HPLC analysis further confirmed that the changes in purine contents in bacteria after antibiotic treatment were consistent with the trends in electrochemical signals. The evaluation of antibiotic antibacterial ability by H‐LSV showed good consistency with results from plate counting and turbidity methods, but was closer to the results of plate counting. The inhibition rates of antibiotics on E. coli detected by H‐LSV and S‐LSV also showed high consistency, indicating that short‐term high‐temperature treatment of E. coli did not affect the response of the bacterium to the inhibitory activity of antibiotics.


  • Electrochemical response mechanism of DNA damaged cells: DNA damage repair and purine metabolism activation

    by Shulan Qi, Jiaqi Fu, Yue Li, Chaoqun Fei, Jiahuan Zhang, Liyuan Sui, Shi Zhou, Jinlian Li, Yanli Zhao, Dongmei Wu


  • The toxicity response of the electrochemical signal of the cell to the drug metabolized by the S9 system

    by Jiahuan Zhang, Chaoqun Fei, Shulan Qi, Jiaqi Fu, Shi Zhou, Zhong Wang, Jinlian Li, Yanli Zhao, Dongmei Wu

    The electrochemical detection method of cytotoxicity using intracellular purines as biomarkers has shown great potential for in vitro drug toxicity evaluation. However, no electrochemical detection system based on an in vitro drug metabolism mechanism has been devised. In this paper, electrochemical voltammetry was used to investigate the effect of the S9 system on the electrochemical behavior of HepG2 cells, and benzo[a]pyrene, fluoranthene, and pyrene were employed to investigate the sensitivity of electrochemical signals of cells to the cytotoxicity of drugs metabolized by the S9 system. The results showed that, within 8 h of exposure to the S9 system, the electrochemical signal of HepG2 cells at 0.7 V did not alter noticeably. The levels of xanthine, guanine, hypoxanthine, and adenine in the cells were not significantly altered. Compared with the absence of S9 system metabolism, benzo[a]pyrene and fluoranthene processed by the S9 system decreased the electrochemical signal of the cells in a dose-dependent manner, while pyrene did not change it appreciably. HPLC also revealed that benzo[a]pyrene and fluoranthene metabolized by the S9 system decreased the intracellular purine levels, whereas pyrene had no effect on them before and after S9 system metabolism. The cytotoxicity results of the three drugs examined by electrochemical voltammetry and MTT assay showed a strong correlation and good agreement. The S9 system had no effect on the intracellular purine levels or the electrochemical signal of cells. When the drug was metabolized by the S9 system, variations in cytotoxicity could be precisely detected by electrochemical voltammetry.


  • Improvement of membrane stabilizer on the rehydrated reconstruction of spray-dried mannitol-based liposome powder

    by Chunxue Liang, Jincheng Du, Ting Hou, Liyuan Sui, Jinlian Li, Yanli Zhao, Dongmei Wu