MSMario Schwarz

Mario Schwarz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mario Schwarz has a total of 363 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Determination of the muon lifetime in Se 76 with the MONUMENT experiment

    by G. R. Araujo, D. Bajpai, L. Baudis, V. Belov, E. Bossio, T. E. Cocolios, H. Ejiri, M. Fomina, K. Gusev, I. H. Hashim, et al.

    Ordinary muon capture provides a benchmark for the nuclear physics models of neutrinoless 39 double beta decay under comparable momentum transfer conditions. The total capture strength defines the lifetime of the muonic atom. The muon lifetime in Se 76 , the daughter nucleus of Ge 76 , was determined with improved accuracy by the MONUMENT collaboration, using an array of high-purity germanium detectors and a set of scintillator counters at the π E 1 muon beam line of the Paul Scherrer Institute. The new value of ( 135.1 ± 0.5 ) ns agrees with phenomenological calculations based on the quasiparticle random-phase approximation with unquenched axial-vector coupling.

  • Open Access

    42Ar production and injection to a liquid argon environment for background mitigation studies

    by Mario Schwarz, Christoph Vogl, Niko N.P.N. Lay, Tommaso Comellato, Gunther Korschinek, Moritz Neuberger, Oskar Moras, Patrick Krause, Stefan Schönert


  • Top Cited Papers
    Open Access

    First Results on the Search for Lepton Number Violating Neutrinoless Double- β Decay with the LEGEND-200 Experiment

    by H Acharya, N Ackermann, M Agostini, A Alexander, C Andreoiu, G R Araujo, F T Avignone, M Babicz, W Bae, A M Bakalyarov, et al.

    The LEGEND Collaboration is searching for neutrinoless double-beta ( 0 ν β β ) decay by operating high-purity germanium detectors enriched in Ge 76 in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0 ν β β decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5 − 0.2 + 0.3 cts / ( keV ton yr ) in the 0 ν β β decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 × 10 26 yr on the half-life of 0 ν β β decay, reveals no evidence for a signal and sets a new observed lower limit at T 1 / 2 0 ν > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range m β β < 75 – 200 meV , depending on the adopted nuclear matrix element.


  • Open Access

    $^{42}$Ar Production and Injection to a Liquid Argon Environment for Background Mitigation Studies

    by Mario Schwarz, Christoph Vogl, Niko N. P. N. Lay, Tommaso Comellato, Gunther Korschinek, Moritz Neuberger, Oskar Moras, Patrick Krause, Stefan Schönert

    Atmosphere-sourced argon contains traces of $^{42}$Ar, whose $β^-$-decaying progeny $^{42}$K represents a significant intrinsic background for rare-event experiments using liquid argon (LAr) as detector or shielding medium. Understanding and mitigating this background is crucial for current and future large-scale detectors in neutrino and dark-matter physics. To enable controlled studies of $^{42}$K behavior and suppression techniques, $^{42}$Ar was produced by irradiating natural argon with 34 MeV $^{7}$Li$^{3+}$ ions at the Maier-Leibnitz-Laboratorium tandem accelerator, using beam currents of $101 \pm 5$ nA and $140 \pm 5$ nA, yielding $476 \pm 9$ Bq within two weeks, corresponding to a production rate of $\sim 1 \times 10^{6}$ atoms$\,$s$^{-1}$. The activated argon was injected into the one-ton SCARF cryostat, where two HPGe detectors monitored the subsequent $^{42}$K activity build-up. A time-dependent model describing $^{42}$Ar mixing and $^{42}$K equilibration in LAr yielded characteristic mixing time constants between one and two days. The established production and injection capability provides a reproducible platform for high-statistics $^{42}$K background studies, essential for developing and validating suppression strategies for next-generation LAr-based rare-event experiments such as LEGEND-1000.

  • Open Access

    A liquid-phase loop-mode argon purification system

    by Christoph Vogl, Mario Schwarz, Patrick Krause, Grzegorz Zuzel, Stefan Schönert

    Noble gas and liquid detectors rely on high chemical purity for successful operation. While gaseous purification has emerged as a reliable method of producing high-purity noble fluids, the requirement for large mass flows drives the development of liquid-phase purification. We constructed a medium-scale liquid argon (LAr) purification system based on a copper catalyst and 4 Å molecular sieve capable of purifying 1 t of commercial LAr 5.0 to a long effective triplet lifetime of τ3 ∼ 1.3 μs. We further demonstrate that a quenched effective triplet lifetime of τ3 ∼ 1 μs, due to contamination by air, can be recovered in loop-mode purification to τ3 ∼ 1.3 μs after > 20 volume exchanges.


  • Open Access

    A plastic scintillation muon veto for sub-Kelvin temperatures

    by A. Erhart, V. Wagner, A. Wex, C. Goupy, D. Lhuillier, E. Namuth, C. Nones, R. Rogly, V. Savu, M. Schwarz, et al.


  • Open Access

    A Plastic Scintillation Muon Veto for Sub-Kelvin Temperatures

    by A. Erhart, V. Wagner, A. Wex, C. Goupy, D. Lhuillier, E. Namuth, C. Nones, R. Rogly, V. Savu, M. Schwarz, et al.

    Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we developed a cryogenic muon veto equipped with wavelength shifting fibers and a silicon photo multiplier operating inside a dilution refrigerator. The achievable compactness of cryostat-internal integration is a key factor in keeping the muon rate to a minimum while maximizing coverage. The thermal and light output properties of a plastic scintillation detector were examined. We report first data on the thermal conductivity and heat capacity of the polystyrene-based scintillator UPS-923A over a wide range of temperatures extending below one Kelvin. The light output was measured down to 0.8K and observed to increase by a factor of 1.61$\pm$0.05 compared to 300K. The development of an organic plastic scintillation muon veto operating in sub-Kelvin temperature environments opens new perspectives for rare-event searches with cryogenic detectors at sites lacking substantial overburden.

  • Open Access

    Liquid Argon Instrumentation and Monitoring in LEGEND-200

    by Mario Schwarz, Patrick Krause, Andreas Leonhardt, Laszlo Papp, Stefan Schönert, Christoph Wiesinger, Maria Fomina, Konstantin Gusev, Nadezda Rumyantseva, Egor Shevchik, et al.

    LEGEND is the next-generation experiment searching for the neutrinoless double beta decay in 76Ge. The first stage, LEGEND-200, takes over the cryogenic infrastructure of GERDA at LNGS: an instrumented water tank surrounding a 64 m3 liquid argon cryostat. Around 200 kg of Ge detectors will be deployed in the cryostat, with the liquid argon acting as cooling medium, high-purity passive shielding and secondary detection medium. For the latter purpose, a liquid argon instrumentation is developed, based on the system used in GERDA Phase II. Wavelength shifting fibers coated with TPB are arranged in two concentric barrels. Both ends are read out by SiPM arrays. A wavelength shifting reflector surrounds the array in order to enhance the light collection far from the array. The LLAMA is installed in the cryostat to permanently monitor the optical parameters and to provide in-situ inputs for modeling purposes. The design of all parts of the LEGEND-200 LAr instrumentation is presented. An overview of the geometry, operation principle, and off-line data analysis of the LLAMA is shown.


  • Open Access

    Measurements of the Lifetime of Orthopositronium in the LAB-Based Liquid Scintillator of JUNO

    by Mario Schwarz, Sabrina M. Franke, Lothar Oberauer, Miriam D. Plein, Hans Th. J. Steiger, Marc Tippmann

    Electron antineutrinos are detected in organic liquid scintillator based neutrino experiments by means of the inverse beta decay, producing both a positron and a neutron. The positron may form a bound state together with an electron, called positronium (Ps). The longer-lived spin state of Ps, orthopositronium (o-Ps) has a lifetime of about $3\,\mathrm{ns}$ in organic liquid scintillators (LS). Its formation changes the time distribution of photon emission, which affects positron reconstruction algorithms and allows the application of pulse shape discrimination (PSD) to distinguish electron from positron events. In this work, we measured the lifetime $\tau_2$ of o-Ps in the linear alkylbenzene (LAB) based LS of the JUNO (Jiangmen Underground Neutrino Observatory) experiment including wavelength shifters, obtaining $\tau_2 = 2.97\,\mathrm{ns} \pm 0.04\,\mathrm{ns}$. Due to systematics, which are not yet completely understood, we are not able to give a final result for the o-Ps formation probability $I_2$. We use a novel type of setup, which allows a better background suppression as compared to commonly used PALS (positron annihilation lifetime spectroscopy) measurements.