Kwangrak Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kwangrak Kim has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Jiwoong Kim
Metrology and Inspection Equipment R&D Team, Mechatronics Research, Samsung Electronics Co., Ltd., hwaseong-si, Republic of Korea
4 shared publicationsMyungjun Lee
Metrology and Inspection Equipment R&D Team, Mechatronics Research, Samsung Electronics Co., Ltd., hwaseong-si, Republic of Korea
3 shared publicationsTaeyong Jo
Metrology and Inspection Equipment R&D Team, Mechatronics Research, Samsung Electronics Co., Ltd., hwaseong-si, Republic of Korea
3 shared publicationsHyenok Park
Metrology and Inspection Equipment R&D Team, Mechatronics Research, Samsung Electronics Co., Ltd., hwaseong-si, Republic of Korea
2 shared publicationsJangryul Park
Metrology and Inspection Equipment R&D Team, Mechatronics Research, Samsung Electronics Co., hwaseong-si, Republic of Korea
2 shared publicationsJeonghyun Wang
Metrology and Inspection Equipment R&D Team, Mechatronics Research, Samsung Electronics Co., Ltd., hwaseong-si, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 20 June 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3 (1) , 1-15
Automatic beam optimization method for scanning electron microscopy based on electron beam Kernel estimation
Scanning Electron Microscopy (SEM) leverages electron wavelengths for nanoscale imaging, necessitating precise parameter adjustments like focus, stigmator, and aperture alignment. However, traditional methods depend on skilled personnel and are time-consuming. Existing auto-focus and auto-stigmation techniques face challenges due to interdependent nature of these parameters and sample diversity. We propose a beam kernel estimation method to independently optimize SEM parameters, regardless of sample variations. Our approach untangles parameter influences, enabling concurrent optimization of focus, stigmator x, y, and aperture-align x, y. It achieves robust performance, with average errors of 1.00 μm for focus, 0.30% for stigmators, and 0.79% for aperture alignment, surpassing sharpness-based approach with its average errors of 6.42 μm for focus and 2.32% for stigmators and lacking in aperture-align capabilities. Our approach addresses SEM parameter interplay via blind deconvolution, facilitating rapid and automated optimization, thereby enhancing precision, efficiency, and applicability across scientific and industrial domains.
- 20 June 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3 (1) , 1-15
Open AccessAutomatic beam optimization method for scanning electron microscopy based on electron beam Kernel estimation
Scanning Electron Microscopy (SEM) leverages electron wavelengths for nanoscale imaging, necessitating precise parameter adjustments like focus, stigmator, and aperture alignment. However, traditional methods depend on skilled personnel and are time-consuming. Existing auto-focus and auto-stigmation techniques face challenges due to interdependent nature of these parameters and sample diversity. We propose a beam kernel estimation method to independently optimize SEM parameters, regardless of sample variations. Our approach untangles parameter influences, enabling concurrent optimization of focus, stigmator x, y, and aperture-align x, y. It achieves robust performance, with average errors of 1.00 μm for focus, 0.30% for stigmators, and 0.79% for aperture alignment, surpassing sharpness-based approach with its average errors of 6.42 μm for focus and 2.32% for stigmators and lacking in aperture-align capabilities. Our approach addresses SEM parameter interplay via blind deconvolution, facilitating rapid and automated optimization, thereby enhancing precision, efficiency, and applicability across scientific and industrial domains.
- Open Access
- 28 May 2024
- Published by Springer Nature in Light: Science & Applications
- Vol. 13 (1) , 1-14
Microsphere-assisted hyperspectral imaging: super-resolution, non-destructive metrology for semiconductor devices
As semiconductor devices shrink and their manufacturing processes advance, accurately measuring in-cell critical dimensions (CD) becomes increasingly crucial. Traditional test element group (TEG) measurements are becoming inadequate for representing the fine, repetitive patterns in cell blocks. Conventional non-destructive metrology technologies like optical critical dimension (OCD) are limited due to their large spot diameter of approximately 25 μm, which impedes their efficacy for detailed in-cell structural analysis. Consequently, there is a pressing need for small-spot and non-destructive metrology methods. To address this limitation, we demonstrate a microsphere-assisted hyperspectral imaging (MAHSI) system, specifically designed for small spot optical metrology with super-resolution. Utilizing microsphere-assisted super-resolution imaging, this system achieves an optical resolution of 66 nm within a field of view of 5.6 μm × 5.6 μm. This approach effectively breaks the diffraction limit, significantly enhancing the magnification of the system. The MAHSI system incorporating hyperspectral imaging with a wavelength range of 400–790 nm, enables the capture of the reflection spectrum at each camera pixel. The achieved pixel resolution, which is equivalent to the measuring spot size, is 14.4 nm/pixel and the magnification is 450X. The MAHSI system enables measurement of local uniformity in critical areas like corners and edges of DRAM cell blocks, areas previously challenging to inspect with conventional OCD methods. To our knowledge, this approach represents the first global implementation of microsphere-assisted hyperspectral imaging to address the metrology challenges in complex 3D structures of semiconductor devices.
- 28 May 2024
- Published by Springer Nature in Light: Science & Applications
- Vol. 13 (1) , 1-14
Open AccessMicrosphere-assisted hyperspectral imaging: super-resolution, non-destructive metrology for semiconductor devices
As semiconductor devices shrink and their manufacturing processes advance, accurately measuring in-cell critical dimensions (CD) becomes increasingly crucial. Traditional test element group (TEG) measurements are becoming inadequate for representing the fine, repetitive patterns in cell blocks. Conventional non-destructive metrology technologies like optical critical dimension (OCD) are limited due to their large spot diameter of approximately 25 μm, which impedes their efficacy for detailed in-cell structural analysis. Consequently, there is a pressing need for small-spot and non-destructive metrology methods. To address this limitation, we demonstrate a microsphere-assisted hyperspectral imaging (MAHSI) system, specifically designed for small spot optical metrology with super-resolution. Utilizing microsphere-assisted super-resolution imaging, this system achieves an optical resolution of 66 nm within a field of view of 5.6 μm × 5.6 μm. This approach effectively breaks the diffraction limit, significantly enhancing the magnification of the system. The MAHSI system incorporating hyperspectral imaging with a wavelength range of 400–790 nm, enables the capture of the reflection spectrum at each camera pixel. The achieved pixel resolution, which is equivalent to the measuring spot size, is 14.4 nm/pixel and the magnification is 450X. The MAHSI system enables measurement of local uniformity in critical areas like corners and edges of DRAM cell blocks, areas previously challenging to inspect with conventional OCD methods. To our knowledge, this approach represents the first global implementation of microsphere-assisted hyperspectral imaging to address the metrology challenges in complex 3D structures of semiconductor devices.
- Open Access
- 24 January 2024
- Published by Springer Nature in Research Square
Automatic Beam Optimization Method for Scanning Electron Microscopy based on Electron Beam Kernel Estimation
Scanning Electron Microscopy (SEM) leverages electron wavelengths for nanoscale imaging. Achieving optimal imaging requires precise adjustment of parameters like focus, stigmator, and aperture alignment, and therefore a process traditionally relies on skilled personnel and time-consuming adjustments. Existing auto-focus (AF) and auto-stigmation (AS) methods face challenges due to the interdependent nature of these parameters and sample diversity. This paper introduces a novel beam kernel estimation method, designed to independently optimize SEM parameters, irrespective of sample variations. Our approach disentangles the mutual influences among parameters, enabling concurrent optimization of focus, stigmator x, y, and aperture-align x, y. This method demonstrates robust performance, yielding average errors of 1.00µm for focus, 0.30% for stigmators, and 2.28% for aperture alignment, significantly outperforming the sharpness-based approach with its average errors of 6.42µm for focus and 2.32% for stigmators, and lacking in aperture-align capabilities. The key innovation of our approach lies in its ability to address the complex interplay of SEM parameters through a blind deconvolution model, facilitating rapid and automated optimization. This advancement not only enhances the precision and efficiency of SEM operations but also broadens its applicability across various scientific and industrial fields.
- 24 January 2024
- Published by Springer Nature in Research Square
Open AccessAutomatic Beam Optimization Method for Scanning Electron Microscopy based on Electron Beam Kernel Estimation
Scanning Electron Microscopy (SEM) leverages electron wavelengths for nanoscale imaging. Achieving optimal imaging requires precise adjustment of parameters like focus, stigmator, and aperture alignment, and therefore a process traditionally relies on skilled personnel and time-consuming adjustments. Existing auto-focus (AF) and auto-stigmation (AS) methods face challenges due to the interdependent nature of these parameters and sample diversity. This paper introduces a novel beam kernel estimation method, designed to independently optimize SEM parameters, irrespective of sample variations. Our approach disentangles the mutual influences among parameters, enabling concurrent optimization of focus, stigmator x, y, and aperture-align x, y. This method demonstrates robust performance, yielding average errors of 1.00µm for focus, 0.30% for stigmators, and 2.28% for aperture alignment, significantly outperforming the sharpness-based approach with its average errors of 6.42µm for focus and 2.32% for stigmators, and lacking in aperture-align capabilities. The key innovation of our approach lies in its ability to address the complex interplay of SEM parameters through a blind deconvolution model, facilitating rapid and automated optimization. This advancement not only enhances the precision and efficiency of SEM operations but also broadens its applicability across various scientific and industrial fields.
- 1 January 2023
- Published by Optica Publishing Group
- p. AM2M.4
Microsphere-assisted Hybrid Spectroscopic Reflectometry Using Hyperspectral Imaging for Nanospot 3D Semiconductor Metrology
We first demonstrate a microsphere-assisted spectroscopic reflectometry technique using hyperspectral imaging geometry, resulting in the extremely small spot measurement with the maximized throughput. The proposed technique is suitable for the measurement of complex semiconductor devices.
- 1 January 2023
- Published by Optica Publishing Group
- p. AM2M.4
Microsphere-assisted Hybrid Spectroscopic Reflectometry Using Hyperspectral Imaging for Nanospot 3D Semiconductor Metrology
We first demonstrate a microsphere-assisted spectroscopic reflectometry technique using hyperspectral imaging geometry, resulting in the extremely small spot measurement with the maximized throughput. The proposed technique is suitable for the measurement of complex semiconductor devices.