Hiroshi Takeuchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hiroshi Takeuchi has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Takeo Nishitani
Graduate School of Engineering, Nagoya University
3 shared publications Chitose Nakaya
Central Research Lab., HITACHI Ltd., Kokubunji, Tokyo 185, Japan
1 shared publication- Cris W. Barnes
Los Alamos National Laboratory, Los Alamos, NM 87545, USA
1 shared publication DOSUE-RR Collaboration
1 shared publication- Daisuke Takeuchi
National Institute of Advanced Industrial Science and Technology
1 shared publication H. Kubo
Japan Atomic Energy Research Institute, Naka Fusion Research Establishment, Naka-machi, Naka-gun, Ibaraki-ken, Japan
1 shared publication
Latest Publications
- Open Access
- 25 January 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 109 (1) , 012008
Search for dark photon dark matter in the mass range using millimeter-wave receiver and radioshielding boxDark photons have been considered potential candidates for dark matter. The dark photon dark matter (DPDM) has a mass and interacts with electromagnetic fields via kinetic mixing with a coupling constant of . Thus, DPDMs are converted into ordinary photons at metal surfaces. Using a millimeter-wave receiver set in a radioshielding box, we performed experiments to detect the conversion photons from the DPDM in the frequency range 10–18 GHz, which corresponds to a mass range . We found no conversion photon signal in this range and set the upper limits to at a 95% confidence level.- 25 January 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 109 (1) , 012008
Open AccessSearch for dark photon dark matter in the mass range using millimeter-wave receiver and radioshielding boxDark photons have been considered potential candidates for dark matter. The dark photon dark matter (DPDM) has a mass and interacts with electromagnetic fields via kinetic mixing with a coupling constant of . Thus, DPDMs are converted into ordinary photons at metal surfaces. Using a millimeter-wave receiver set in a radioshielding box, we performed experiments to detect the conversion photons from the DPDM in the frequency range 10–18 GHz, which corresponds to a mass range . We found no conversion photon signal in this range and set the upper limits to at a 95% confidence level. - 1 February 2001
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 72 (2) , 1406-1410
Diamond radiation detector made of an ultrahigh-purity type IIa diamond crystal grown by high-pressure and high-temperature synthesis
Synthetic diamond radiation detectors made of ultrahigh-purity type IIa diamond crystals were developed. The diamond crystals, which were grown by high-pressure and high-temperature synthesis, contained less nitrogen impurity than 0.1 ppm, i.e., 1/10 of conventional type IIa diamond crystals. Since the ultrahigh-purity type IIa diamond crystal was a p-type semiconductor due to a trace impurity of boron, a structure consisting of Schottky and ohmic contacts was adopted for the detectors to suppress an increase in leakage current. For the same purpose, a metal–insulator–semiconductor structure using a chemical vapor deposition diamond insulating layer was adopted for one of the detectors. Plural peaks were observed in the 5.486 MeV α energy spectra obtained by the detectors; motion of holes produced the main part of output pulses from the detectors on these measurements. One of the peaks in each spectrum was hardly influenced by light irradiation, even ultraviolet light of 370 nm (3.4 eV), compared with a peak obtained by the conventional type IIa diamond radiation detector. This experimental result indicated that there was a superior part in the crystal where deep energy levels did not exist so much. Although there was no direct evidence, influence of a distribution of the boron impurity in the crystal was expected. On the other hand, electron trapping severely occurred and resulted in loss in charge collection; an effect of the reduction in the nitrogen impurity was not confirmed on the behavior of electrons.
- 1 February 2001
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 72 (2) , 1406-1410
Diamond radiation detector made of an ultrahigh-purity type IIa diamond crystal grown by high-pressure and high-temperature synthesis
Synthetic diamond radiation detectors made of ultrahigh-purity type IIa diamond crystals were developed. The diamond crystals, which were grown by high-pressure and high-temperature synthesis, contained less nitrogen impurity than 0.1 ppm, i.e., 1/10 of conventional type IIa diamond crystals. Since the ultrahigh-purity type IIa diamond crystal was a p-type semiconductor due to a trace impurity of boron, a structure consisting of Schottky and ohmic contacts was adopted for the detectors to suppress an increase in leakage current. For the same purpose, a metal–insulator–semiconductor structure using a chemical vapor deposition diamond insulating layer was adopted for one of the detectors. Plural peaks were observed in the 5.486 MeV α energy spectra obtained by the detectors; motion of holes produced the main part of output pulses from the detectors on these measurements. One of the peaks in each spectrum was hardly influenced by light irradiation, even ultraviolet light of 370 nm (3.4 eV), compared with a peak obtained by the conventional type IIa diamond radiation detector. This experimental result indicated that there was a superior part in the crystal where deep energy levels did not exist so much. Although there was no direct evidence, influence of a distribution of the boron impurity in the crystal was expected. On the other hand, electron trapping severely occurred and resulted in loss in charge collection; an effect of the reduction in the nitrogen impurity was not confirmed on the behavior of electrons.
- Open Access
- 1 January 2000
- Published by Ceramic Society of Japan in Journal of the Ceramic Society of Japan
- Vol. 108 (1264) , 1096-1102
Oxidation Kinetics and Mechanical Property of Stoichiometric SiC Fibers (Hi-Nicalon-S).
- 1 January 2000
- Published by Ceramic Society of Japan in Journal of the Ceramic Society of Japan
- Vol. 108 (1264) , 1096-1102
Open AccessOxidation Kinetics and Mechanical Property of Stoichiometric SiC Fibers (Hi-Nicalon-S).
- 1 January 1995
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 66 (1) , 594-596
Infrared TV measurement of fast ion loss on JT-60U
- 1 January 1995
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 66 (1) , 594-596
Infrared TV measurement of fast ion loss on JT-60U
- 1 January 1995
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 34 (1R) , 312-315
Acoustic Properties of Lens Materials for Ultrasonic Probes
The acoustic velocities and densities of 20 types of commercial rubber have been measured at a frequency of 2 MHz at room temperature, and they are evaluated in terms of their application to an acoustic lens or an acoustic window of probes of an ultrasonic diagnostic instrument. Fluorosilicone rubber and phoshazene rubber have lower acoustic velocities than the human body, and they have excellent impedance matching with the human body. Both the acoustic velocities and densities of butadiene rubber, polybutadiene rubber, acrylic rubber and polyurethane match those of the human body. It is also described that rubber having good impedance matching with the human body can be fabricated by adjusting the volume fraction of the added filler.
- 1 January 1995
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 34 (1R) , 312-315
Acoustic Properties of Lens Materials for Ultrasonic Probes
The acoustic velocities and densities of 20 types of commercial rubber have been measured at a frequency of 2 MHz at room temperature, and they are evaluated in terms of their application to an acoustic lens or an acoustic window of probes of an ultrasonic diagnostic instrument. Fluorosilicone rubber and phoshazene rubber have lower acoustic velocities than the human body, and they have excellent impedance matching with the human body. Both the acoustic velocities and densities of butadiene rubber, polybutadiene rubber, acrylic rubber and polyurethane match those of the human body. It is also described that rubber having good impedance matching with the human body can be fabricated by adjusting the volume fraction of the added filler.
- 1 October 1992
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 63 (10) , 4558
Absolute calibration of the JT-60U neutron monitor using a 252Cf neutron source (abstract)a)
Absolutely calibrated measurements of the neutron yield are important for the evaluation of the plasma performance such as the fusion gain Q in D-D operating tokamaks. The time-resolved neutron yield is measured with 235U and 238U fission chambers and 3He proportional counters in the JT-60U tokamak. The in situ calibration was performed by moving the 252Cf neutron source toroidally through the JT-60 vacuum vessel. Detection efficiencies of three 235U and two 3He detectors were measured for 92 locations of the neutron point source in toroidal scans at two different major radii. The total detection efficiency for the torus neutron source was obtained by the averaging the point efficiencies over the whole toroidal angle. The uncertainty of the resulting detection efficiency for the plasma neutrons is estimated to be ±11%.
- 1 October 1992
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 63 (10) , 4558
Absolute calibration of the JT-60U neutron monitor using a 252Cf neutron source (abstract)a)
Absolutely calibrated measurements of the neutron yield are important for the evaluation of the plasma performance such as the fusion gain Q in D-D operating tokamaks. The time-resolved neutron yield is measured with 235U and 238U fission chambers and 3He proportional counters in the JT-60U tokamak. The in situ calibration was performed by moving the 252Cf neutron source toroidally through the JT-60 vacuum vessel. Detection efficiencies of three 235U and two 3He detectors were measured for 92 locations of the neutron point source in toroidal scans at two different major radii. The total detection efficiency for the torus neutron source was obtained by the averaging the point efficiencies over the whole toroidal angle. The uncertainty of the resulting detection efficiency for the plasma neutrons is estimated to be ±11%.
- 1 January 1991
- Published by Elsevier
- p. 379-382
100 MHz Band Ultrasonic Array Transducers Utilizing Epitaxially Grown ZnO films
- 1 January 1991
- Published by Elsevier
- p. 379-382
100 MHz Band Ultrasonic Array Transducers Utilizing Epitaxially Grown ZnO films
- 1 June 1990
- Published by IOP Publishing in Nuclear Fusion
- Vol. 30 (6) , 1095-1105
Radiation losses and global power balance of JT-60 plasmas
The radiation losses and the global power balance for Ohmic and neutral beam heated plasmas have been investigated in different JT-60 configurations. Discharges with a TiC coated molybdenum wall and with a graphite wall, with limiter, outer and lower X-point configurations have been studied by bolometric measurements, thermocouples and an infrared TV camera. In neutral beam heated outer X-point discharges with a TiC coated molybdenum first wall, the radiation loss of the main plasma was very low (10% of the absorbed power). The radiation loss due to oxygen was dominant in this case. On the contrary, in discharges with TiC coated molybdenum limiters the radiation loss was very high (>60% of the absorbed power). In the discharges with a graphite wall the radiated power from the main plasma was 20-25% for both limiter and lower X-point configurations. In lower X-point discharges the main contributor to the radiation loss was oxygen, whereas in limiter discharges the loss due to carbon was equal to the loss due to oxygen. The radiation loss from the lower X-point divertor increased with increasing electron density of the main plasma.
- 1 June 1990
- Published by IOP Publishing in Nuclear Fusion
- Vol. 30 (6) , 1095-1105
Radiation losses and global power balance of JT-60 plasmas
The radiation losses and the global power balance for Ohmic and neutral beam heated plasmas have been investigated in different JT-60 configurations. Discharges with a TiC coated molybdenum wall and with a graphite wall, with limiter, outer and lower X-point configurations have been studied by bolometric measurements, thermocouples and an infrared TV camera. In neutral beam heated outer X-point discharges with a TiC coated molybdenum first wall, the radiation loss of the main plasma was very low (10% of the absorbed power). The radiation loss due to oxygen was dominant in this case. On the contrary, in discharges with TiC coated molybdenum limiters the radiation loss was very high (>60% of the absorbed power). In the discharges with a graphite wall the radiated power from the main plasma was 20-25% for both limiter and lower X-point configurations. In lower X-point discharges the main contributor to the radiation loss was oxygen, whereas in limiter discharges the loss due to carbon was equal to the loss due to oxygen. The radiation loss from the lower X-point divertor increased with increasing electron density of the main plasma.