VMVera Maslova

Vera Maslova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vera Maslova has a total of 144 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electroanatomical properties and high-density mapping guided targeted isolation of superior vena cava

    by Vera Maslova, Hannah Budke, Adrian Zaman, Martina E. Spehlmann, Derk Frank, Evgeny Lian

    Introduction: Superior vena cava isolation (SVCI) is associated with complications such as sinus node (SN) and phrenic nerve (PN) injury or SVC stenosis. Our study assessed the electrophysiological properties of the SVC and use of high-density mapping for targeted SVCI by ablating preferential conduction sites to avoid these complications. Methods: Eighty-three consecutive patients, undergoing HD mapping of the SVC during AF re-ablation procedures were prospectively included. Conduction block (CB) lines between the right atrium and SVC, location of the sinus node (SN) and phrenic nerve (PN), and their spatial relationship to the ablation line (AbL) were assessed. Results: CB lines were present in 98% of patients, with gaps identified in all SVC segments, most frequently posterior (73%), with a median gap width of 23.9 (14.3–37.8) mm. All gaps expressed decremental properties in the EP study. Ablation was performed in 35 (42%) patients and was achieved in all cases using targeted segmental ablation, closing the gaps between the CB lines.Median ablation duration was 88 (66; 161) seconds with a median of 8 (6–12) radiofrequency applications. SN was separated from SVC with CB line in 98% of cases, what excluded necessity to ablate in this area, distance from the AbL to the SN exit zone was 8.9 (6-14.7) mm. PN was located outside the areas of preferential conduction in all cases, distance from AbL to the PN was 10.4 (6.7–12.1) mm. No complications occurred. Conclusions: HD mapping-guided, targeted segmental SVCI using RF energy is feasible and safe.

  • Kardiale Notfälle

    by Matthias Petersen, Vera Maslova, Adrian Zaman, Zeljka Radic, Bernd Panholzer, Jefferson Losó

  • International Survey on Vein of Marshall Retrograde Ethanol Infusion

    by Benjamin De Becker, Nicolas Derval, Reshma Amin, Milad El Haddad, Thomas Pambrun, Benjamin Bouyer, Clara Francois, Maarten De Smet, El Mehdi Channan, Nicolas Blankoff, et al.

    BACKGROUND: Retrograde ethanolization of the vein of Marshall (VOM) has been identified as an adjunct technique in the treatment of persistent atrial fibrillation (AF) and left atrial tachycardia, as stated in the last consensus statement on ablation of AF. However, there is a lack of high-volume data on the technique. METHODS: Through the collection of data from worldwide centers, we performed this international survey that aims to analyze the safety and procedural characteristics of VOM ethanolization in patients referred for treatment of AF or left atrial tachycardia. RESULTS: We included 5579 patients (66 years; range, 20–93) from 26 centers, who underwent VOM ethanolization between 2008 and 2024 for persistent AF (81%), paroxysmal AF (9%), or left atrial tachycardia (10%) under deep sedation (53%) or general anesthesia (47%). A concomitant mitral isthmus line was attempted in 79% of the cases, achieving mitral isthmus block in 98% of patients. There were 0.92% of periprocedural serious adverse events, including 0.09% of peri-procedural death (5 patients). Three patients developed hemodynamic collapse immediately after VOM ethanolization, causing the death of 1 due to anaphylactic shock. One patient died following surgical drainage of pericardial effusion 3 weeks after the procedure. The 3 other deaths were not directly related to VOM ethanolization. Pericardial effusion was observed in 123 patients (2.2%) at the time of or immediately after the procedure, requiring drainage in 20 patients (0.36%) and later in 32 additional patients (0.57%), including 5 (0.09%) requiring drainage. Pacemaker implantation was required in 2 patients (0.04%), 1 for high-grade atrioventricular block and 1 for sinus node dysfunction. CONCLUSIONS: This international survey shows that VOM ethanolization is predominantly performed in patients with persistent AF. It is associated with rare but potentially life-threatening adverse events. Mitral isthmus line ablation results in a very high rate of block when performed concomitantly.


  • Open Access

    De novo pulmonary vein isolation in obese vs nonobese patients under deep sedation: Does obesity increase procedure complexity?

    by Vera Maslova, Marie Ahrens, Ole Rosenthal, Theodor Bau, Peter Magerfleisch, Fabian Moser, Adrian Zaman, Mohammed Saad, Martina Spehlmann, Derk Frank, et al.


  • Open Access

    Safety of ventricular tachycardia ablation under deep sedation with propofol and fentanyl

    by Vera Maslova, Sophie Lange, Tim Kannenberg, Augustin Uckermark, Julius Nebendahl, Arne Clüver, Sami Srouji, Yara Scherkus, Adrian Zaman, Fabian Moser, et al.

    Background: There is no current standard of anaesthetic management for CA of VT. Data on VT ablation under deep sedation with propofol and fentanyl are limited. Objective: The aim was to evaluate the feasibility and safety of CA of VT under deep sedation with propofol and fentanyl. Methods: Data from 134 procedures in 106 patients undergoing CA for VT under sedation with propofol and fentanyl were prospectively included. Three groups were defined and compared: group 1 (no VT induction, n =36); group 2 (induction of hemodynamically unstable VT, n =42), and group 3 (induction of hemodynamically stable VT, n =56). Results: Median age was 64 years, 84% were male, and 97% had structural heart disease. Group 2 had a higher proportion of patients with DCM ( p =0.04) and severely reduced LVEF ( p =0.024). Unipolar RF ablation was performed in 95% of procedures, bipolar in 12%, and alcohol ablation in 4%. Epicardial access was utilized in 18%. Radiation dose was higher in group 2 ( p =0.04), while post-ablation non-inducibility was more frequently achieved in group 3 ( p =0.045). There were no cases of profound hypotension or intubation associated with sedation. CPR was performed in seven procedures due to PEA, all in group 2 ( p <0.001) with ROSC achieved in all cases within 3 min. No differences were observed in complication rates or hospital stay. Conclusion: CA for VT under deep sedation with propofol and fentanyl in patients with structural heart disease is feasible and safe, irrespective of VT induction, mapping, and ablation approach. Hemodynamic instability, hypotension, and desaturation can be effectively managed. Graphical


  • Open Access

    Prediction of Ablation Index and Lesion Size Index for Local Impedance Drop-Guided Ablation

    by Lukas Sprenger, Fabian Moser, Vera Maslova, Adrian Zaman, Marc Nonnenmacher, Sven Willert, Derk Frank, Evgeny Lian

    (1) Background: The effectiveness of RF ablation for PVI depends on the lesion location and size to achieve continuous and durable lesion lines. AI and LSI are widely accepted lesion metrics for guiding the ablation procedure. LI dynamics is another parameter that guides PVI and does not rely on input variables. Limited data are available on a direct comparison between lesion metrics. Our study aims to compare RF application durations and influencing factors during index-guided (AI and LSI) and LI-guided approaches by predicting lesion metrics using machine learning. (2) Methods: While the coefficients in AI and LSI formulas are not disclosed, we trained custom machine-learning models based on Random Forest and Gradient Boosting Regressors to predict AI and LSI metrics for LI-guided ablations. (3) Results: The median RF application durations differed significantly between the lesion metrics, with 7.32, 19.91, and 11.92 s for AI-, LSI-, and LI-guided procedures, respectively. Mean CF was found to be an important predictor of RF application duration for the AI- and LSI-guided approaches. (4) Conclusions: Depending on the metric used, the significant differences in RF application durations suggest that an AI-guide approach may allow for shorter RF application durations, followed by LSI-guided and LI-guided procedures. Further studies are needed to evaluate the safety and efficacy of these results in a clinical setting.


  • Open Access

    Bipolar radiofrequency ablation of refractory ventricular arrhythmias: results from a multicentre network

    by Piotr Futyma, Arian Sultan, Łukasz Zarębski, Guram Imnadze, Vera Maslova, Stefano Bordignon, Maria Kousta, Sven Knecht, Nikola Pavlović, Petr Peichl, et al.

    Advanced ablation strategies are needed to treat ventricular tachycardia (VT) and premature ventricular complexes (PVC) refractory to standard unipolar radiofrequency ablation (Uni-RFA). Bipolar radiofrequency catheter ablation (Bi-RFA) has emerged as a treatment option for refractory VT and PVC. Multicentre registry data on the use of Bi-RFA in the setting of refractory VT and PVC are lacking. The aim of this Bi-RFA registry is to determine its real-world safety, feasibility, and efficacy in patients with refractory VT/PVC. Consecutive patients undergoing Bi-RFA at 16 European centres for recurring VT/PVC after at least one standard Uni-RFA were included. Second ablation catheter was used instead of a dispersive patch and was positioned at the opposite site of the ablation target. Between March 2021 and August 2024, 91 patients underwent 94 Bi-RFA procedures (74 males, age 62 ± 13, and prior Uni-RFA range 1–8). Indications were recurrence of PVC (n = 56), VT (n = 20), electrical storm (n = 13), or PVC-triggered ventricular fibrillation (n = 2). Procedural time was 160 ± 73 min, Bi-RFA time 426 ± 286 s, and mean Uni-RFA time 819 ± 697 s. Elimination of clinical VT/PVC was achieved in 67 (74%) patients and suppression of VT/PVC in a further 10 (11%) patients. In the remaining 14 patients (15%), no effect on VT/PVC was observed. Three major complications occurred: coronary artery occlusion, atrioventricular block, and arteriovenous fistula. Follow-up lasted 7 ± 8 months. Nineteen patients (61%) remained VT free. ≥80% PVC burden reduction was achieved in 45 (78%). These real-world registry data indicate that Bi-RFA appears safe, is feasible, and is effective in the majority of patients with VT/PVC.


  • Open Access

    Atrial pace mapping using automatic intracardiac pattern matching for ablation of non-sustained atrial tachycardia: a case report

    by Evgeny Lian, Sven Willert, Romina Krüger, Thomas Demming, Derk Frank, Vera Maslova


  • Open Access

    Local impedance drop–guided versus lesion size index–guided pulmonary vein isolation

    by Evgeny Lian, Robert Pantlik, Vera Maslova, Sven Willert, Fabian Moser, Andrew Remppis, Derk Frank, Thomas Demming

    Background: Local tissue impedance drop (LID) and lesion size index (LSI) technologies are valuable for predicting effective lesion formation. This study compares the acute and long-term efficacy of LID-guided versus LSI-guided pulmonary vein isolation (PVI) for atrial fibrillation treatment. Methods: We retrospectively analyzed two patient groups undergoing radiofrequency PVI. In the LID-guided group (n = 35), ablation was performed without contact force monitoring, stopping at the LID plateau (target LID 12 Ohm posterior, 16 Ohm anterior). In the LSI-guided group (n = 31), ablation used contact force information with target LSI (5 anterior, 4 posterior). Both groups utilized a power of 40 W anterior and 30 W posterior, with < 6 mm inter-lesion distance. Gap mapping and touch-up ablation were done if necessary. Results: PVI was achieved with a significantly shorter ablation time in the LSI-guided group (25 min [21;31] vs 30 [27;35], p = 0.035). PV gaps were more frequent in the LID-guided group (74% vs 42%, p = 0.016). Over 11.5 ± 2.9 months follow-up, arrhythmia recurrence was higher in the LID-guided group (34.3% vs 16.1%, p = 0.037). A redo procedure performed in 10 (28.6%) patients in the LID-guided group and 3 (9.7%) in the LSI-guided group showed chronic PV reconnections in 7 out of 10 (70%) and 2 out of 3 (67%) patients, respectively. Conclusions: LSI-guided ablation results in shorter ablation time and fewer PV gaps compared to LID-guided ablation. Despite initial success, LID-guided ablation had higher arrhythmia recurrence and PV reconnections during long-term follow-up compared to LSI-guided ablation. Graphical