Ali Sadoughi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ali Sadoughi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Abhishek Sarkar
Westchester Med Ctr, Dept Med, Div Pulm & Crit Care Med, Valhalla, NY USA
1 shared publication- Aham Okorozo
Pulmonary Division-Department of Medicine, Montefiore Medical Center-Albert Einstein College of Medicine, Bronx, NY, USA
1 shared publication Carol Novotney
Montefiore Med Ctr, Ctr Anim Resources & Educ CARE, Bronx, NY USA
1 shared publicationChristine Chan
Albert Einstein Coll Med, Montefiore Med Ctr, Dept Med, Div Pulmonol, 3411 Wayne Ave,Suite 5H, Bronx, NY 10467 USA
1 shared publicationGerardo Moreno
Montefiore Med Ctr, Ctr Anim Resources & Educ CARE, Bronx, NY USA
1 shared publication- Hyun S. Kim
Pulmonary Division-Department of Medicine, Montefiore Medical Center-Albert Einstein College of Medicine, Bronx, NY, USA
1 shared publication
Latest Publications
- Open Access
- 1 May 2024
- Published by Elsevier in Respiratory Medicine Case Reports
- Vol. 50, 102024
A rare case of straight-back syndrome causing airway obstruction
- 1 May 2024
- Published by Elsevier in Respiratory Medicine Case Reports
- Vol. 50, 102024
Open AccessA rare case of straight-back syndrome causing airway obstruction
- Open Access
- 1 January 2024
- Published by AME Publishing Company in Translational Lung Cancer Research
- Vol. 13 (1) , 60-75
Bronchoscopic deployment and implantation of Diffusing alpha-emitters Radiation Therapy into the lung and mediastinum for treatment of lung cancer: a pre-clinical safety and feasibility study
Background: Radiotherapy is a standard treatment modality in cancer therapy, particularly for lung cancer. Diffusing alpha-emitters Radiation Therapy sources (hereafter, “Alpha DaRTs”) are fixed with Ra-244 (half-life =3.6 days) that releases alpha-emitting atoms into the tumor tissue to an effective range of a few millimeters. Methods: The feasibility, usability, and safety of Alpha DaRTs deployment and implantation via bronchoscopy into the lung parenchyma and mediastinum in a big animal model of healthy swine was studied in two phases: (I) inert and (II) active Alpha DaRTs deployment. The Alpha DaRTs were inserted in both individual and cluster patterns based on a predefined plan. Swine health was monitored throughout the study. The usability of bronchoscopic deployment and implantation was evaluated using a user questionnaire. The movement and migration of the Alpha DaRTs were assessed. Necropsy was performed, and lungs were evaluated via gross pathology and histopathology. Results: A total of 158 Alpha DaRTs were inserted successfully in the lung parenchyma and mediastinum of five swine in two phases. It was possible to deliver and place the Alpha DaRTs in clusters of no more than 4 mm distance between the Alpha DaRTs. No adverse event or change in the health and general condition of animals was observed. Hematologic evaluation did not show any clinically significant abnormality related to the Alpha DaRTs. Histopathology demonstrated local mild inflammatory changes, minimal fibrosis, and dystrophic mineralization with giant cells. Minimal movement and no migration of Alpha DaRTs were observed. Conclusions: Bronchoscopic deployment of Alpha DaRTs in the lung parenchyma and mediastinum of the porcine animal is feasible, precise, and safe.
- 1 January 2024
- Published by AME Publishing Company in Translational Lung Cancer Research
- Vol. 13 (1) , 60-75
Open AccessBronchoscopic deployment and implantation of Diffusing alpha-emitters Radiation Therapy into the lung and mediastinum for treatment of lung cancer: a pre-clinical safety and feasibility study
Background: Radiotherapy is a standard treatment modality in cancer therapy, particularly for lung cancer. Diffusing alpha-emitters Radiation Therapy sources (hereafter, “Alpha DaRTs”) are fixed with Ra-244 (half-life =3.6 days) that releases alpha-emitting atoms into the tumor tissue to an effective range of a few millimeters. Methods: The feasibility, usability, and safety of Alpha DaRTs deployment and implantation via bronchoscopy into the lung parenchyma and mediastinum in a big animal model of healthy swine was studied in two phases: (I) inert and (II) active Alpha DaRTs deployment. The Alpha DaRTs were inserted in both individual and cluster patterns based on a predefined plan. Swine health was monitored throughout the study. The usability of bronchoscopic deployment and implantation was evaluated using a user questionnaire. The movement and migration of the Alpha DaRTs were assessed. Necropsy was performed, and lungs were evaluated via gross pathology and histopathology. Results: A total of 158 Alpha DaRTs were inserted successfully in the lung parenchyma and mediastinum of five swine in two phases. It was possible to deliver and place the Alpha DaRTs in clusters of no more than 4 mm distance between the Alpha DaRTs. No adverse event or change in the health and general condition of animals was observed. Hematologic evaluation did not show any clinically significant abnormality related to the Alpha DaRTs. Histopathology demonstrated local mild inflammatory changes, minimal fibrosis, and dystrophic mineralization with giant cells. Minimal movement and no migration of Alpha DaRTs were observed. Conclusions: Bronchoscopic deployment of Alpha DaRTs in the lung parenchyma and mediastinum of the porcine animal is feasible, precise, and safe.