Chengxiang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chengxiang Wang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Wei Yu
Hubei University of Science and Technology
6 shared publications Baodong Liu
Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, People’s Republic of China
1 shared publication- Baodong Liu
Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
1 shared publication Hai Yin
School of Biomedical Engineering and Imaging , Xianning Medical College , Hubei University of Science and Technology , 437100 Xianning , P. R. China
1 shared publication- Jiaxi Wang
School of Computer Science, Chengdu University, Chengdu, China
1 shared publication Jiemin Que
Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, People’s Republic of China
1 shared publication
Latest Publications
- 10 November 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (45) , 455401
PSF-compensated analytical reconstruction for improved image quality in cone-beam computed laminography
Non-destructive evaluation of high-aspect-ratio electronic components, such as insulated gate bipolar transistors and printed circuit boards, demands reconstruction methods that combine measurement accuracy with high throughput. Cone-beam rotary computed laminography (CL) is usually implemented by tilting the source–detector assembly or the object within a conventional CT geometry. Though mechanically simple, this tilting breaks circular symmetry, so analytic reconstruction suffers from inter-slice aliasing and structural distortion. The CL-filtered backprojection and CL-Feldkamp–Davis–Kress methods directly adopt the ramp filter and weighting factor used in cone-beam CT, without a detailed justification or derivation for why they remain valid in this geometry. This paper derives a frequency-domain pseudoinverse filter over the measurable frequency support from the point spread function (PSF) of the CL geometry. To avoid the prohibitive cost of direct three-dimensional image-domain filtering, we reformulate the operation in the 2D projection domain and handle the resulting nonlinear coordinate mapping via a principled approximation. The key theoretical result is that, under practical assumptions, this approximated filter collapses analytically to a scaled ramp filter, thereby providing the first theoretical justification for the ramp filter and clarifying precisely when it fails. The improved image quality, however, stems from two further components: the projection weighting and a complementary 2D spectral filter that corrects the residual approximation errors. Experiments confirm that the proposed CL-PSF method consistently outperforms other analytic algorithms in correcting structural distortion. The theoretical derivation further motivates three practical strategies for suppressing inter-slice aliasing: restricting the valid reconstruction thickness, restricting the reconstruction volume to a compact region of interest, and adopting a detector with a smaller in-plane size. All three strategies are validated experimentally. The proposed method thus offers a fast and well-founded reconstruction approach for quantitative industrial inspection.
- 10 November 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (45) , 455401
PSF-compensated analytical reconstruction for improved image quality in cone-beam computed laminography
Non-destructive evaluation of high-aspect-ratio electronic components, such as insulated gate bipolar transistors and printed circuit boards, demands reconstruction methods that combine measurement accuracy with high throughput. Cone-beam rotary computed laminography (CL) is usually implemented by tilting the source–detector assembly or the object within a conventional CT geometry. Though mechanically simple, this tilting breaks circular symmetry, so analytic reconstruction suffers from inter-slice aliasing and structural distortion. The CL-filtered backprojection and CL-Feldkamp–Davis–Kress methods directly adopt the ramp filter and weighting factor used in cone-beam CT, without a detailed justification or derivation for why they remain valid in this geometry. This paper derives a frequency-domain pseudoinverse filter over the measurable frequency support from the point spread function (PSF) of the CL geometry. To avoid the prohibitive cost of direct three-dimensional image-domain filtering, we reformulate the operation in the 2D projection domain and handle the resulting nonlinear coordinate mapping via a principled approximation. The key theoretical result is that, under practical assumptions, this approximated filter collapses analytically to a scaled ramp filter, thereby providing the first theoretical justification for the ramp filter and clarifying precisely when it fails. The improved image quality, however, stems from two further components: the projection weighting and a complementary 2D spectral filter that corrects the residual approximation errors. Experiments confirm that the proposed CL-PSF method consistently outperforms other analytic algorithms in correcting structural distortion. The theoretical derivation further motivates three practical strategies for suppressing inter-slice aliasing: restricting the valid reconstruction thickness, restricting the reconstruction volume to a compact region of interest, and adopting a detector with a smaller in-plane size. All three strategies are validated experimentally. The proposed method thus offers a fast and well-founded reconstruction approach for quantitative industrial inspection.
- Open Access
Perspective Transformation-Based Computed Laminography for Artifact Reduction in Non-Destructive Inspection of Printed Circuit Boards
X-ray computed tomography (CT) is widely used in non-destructive testing; however, it exhibits inherent limitations when scanning objects with a large aspect ratio. Computed laminography (CL) provides an alternative solution; nevertheless, due to its distinctive scanning geometry, analytical CL reconstruction methods, such as the filtered back projection (FBP) algorithm, are prone to laminographic and superposition artifacts, thereby degrading image quality. To address this issue, a perspective transformation-based data conversion method (PT-CL-FDK) for cone-beam CL is proposed. Firstly, a virtual detector is introduced, and the perspective transformation relationship between the real and virtual detectors is derived. Secondly, the acquired CL projection data are transformed onto the virtual detector. Finally, the converted projection data are reconstructed using a CL-FDK algorithm. Simulation and real printed circuit board (PCB) experimental results demonstrate that, compared with CL-FBP, the proposed method effectively suppresses superposition artifacts and preserves object boundaries, while significantly enhancing the contrast and resolution of void defects in PCBs.
Open AccessPerspective Transformation-Based Computed Laminography for Artifact Reduction in Non-Destructive Inspection of Printed Circuit Boards
X-ray computed tomography (CT) is widely used in non-destructive testing; however, it exhibits inherent limitations when scanning objects with a large aspect ratio. Computed laminography (CL) provides an alternative solution; nevertheless, due to its distinctive scanning geometry, analytical CL reconstruction methods, such as the filtered back projection (FBP) algorithm, are prone to laminographic and superposition artifacts, thereby degrading image quality. To address this issue, a perspective transformation-based data conversion method (PT-CL-FDK) for cone-beam CL is proposed. Firstly, a virtual detector is introduced, and the perspective transformation relationship between the real and virtual detectors is derived. Secondly, the acquired CL projection data are transformed onto the virtual detector. Finally, the converted projection data are reconstructed using a CL-FDK algorithm. Simulation and real printed circuit board (PCB) experimental results demonstrate that, compared with CL-FBP, the proposed method effectively suppresses superposition artifacts and preserves object boundaries, while significantly enhancing the contrast and resolution of void defects in PCBs.
- 3 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (13) , 135010
Self-supervised learning for low-dose CT image denoising method based on guided image filtering
Objective. low-dose computed tomography (LDCT) images suffer from severe noise due to reduced radiation exposure. Most existing deep learning-based denoising methods require supervised learning with paired training data that is difficult to obtain. To address this limitation, we aim to develop a denoising method that does not rely on paired normal-dose computed tomography data. Approach. we propose a self-supervised denoising method based on guided image filtering (GIF) that requires only LDCT images for training. The method first applies GIF to generate pseudo-labels from LDCT images, enabling the network to learn noise distributions between inputs and pseudo-labels for denoising, without paired data. Then, an attention gate (AG) mechanism is embedded in the decoder stage of a residual network to further enhance denoising performance. Main results. experimental results demonstrate that the proposed method achieves superior performance compared to state-of-the-art unsupervised denoising networks, transformer-based denoising model and post-processing methods, in terms of both visual quality and quantitative metrics. Furthermore, ablation studies are conducted to analyze the impact of different attention mechanisms and the number of AG mechanisms, showing that the proposed network architecture achieves optimal performance. Significance. this work leverages self-supervised learning with GIF to generate pseudo-labels, enabling LDCT denoising without paired data. The embedded AG mechanism, supported by detailed ablation analysis, further enhances denoising performance by improving feature focus and structural preservation.
- 3 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (13) , 135010
Self-supervised learning for low-dose CT image denoising method based on guided image filtering
Objective. low-dose computed tomography (LDCT) images suffer from severe noise due to reduced radiation exposure. Most existing deep learning-based denoising methods require supervised learning with paired training data that is difficult to obtain. To address this limitation, we aim to develop a denoising method that does not rely on paired normal-dose computed tomography data. Approach. we propose a self-supervised denoising method based on guided image filtering (GIF) that requires only LDCT images for training. The method first applies GIF to generate pseudo-labels from LDCT images, enabling the network to learn noise distributions between inputs and pseudo-labels for denoising, without paired data. Then, an attention gate (AG) mechanism is embedded in the decoder stage of a residual network to further enhance denoising performance. Main results. experimental results demonstrate that the proposed method achieves superior performance compared to state-of-the-art unsupervised denoising networks, transformer-based denoising model and post-processing methods, in terms of both visual quality and quantitative metrics. Furthermore, ablation studies are conducted to analyze the impact of different attention mechanisms and the number of AG mechanisms, showing that the proposed network architecture achieves optimal performance. Significance. this work leverages self-supervised learning with GIF to generate pseudo-labels, enabling LDCT denoising without paired data. The embedded AG mechanism, supported by detailed ablation analysis, further enhances denoising performance by improving feature focus and structural preservation.
- 1 July 2025
- Published by IOP Publishing in Inverse Problems
- Vol. 41 (7) , 075010
An approximate analytical reconstruction method in inverse problems of cone-beam rotary computed laminography
Computed tomography is a highly effective inspection methodology for non-destructive testing, however, it faces challenges with objects that have a significant aspect ratio. In such scenarios, computed laminography (CL) serves as a viable alternative. The unique geometric configuration of cone-beam rotary CL makes the classical FDK reconstruction algorithm unsuitable. To address this inverse problem, we proposed an approximate analytical reconstruction method inspired by the core idea of the FDK algorithm. Firstly, we addressed the cone-beam rotary CL reconstruction problem by approximating it as a series of fan-beam reconstruction tasks, and deriving the geometric relationships between the original coordinate system and the fan-beam coordinates. Secondly, the fan-beam reconstruction formula within the fan-beam coordinate system is derived. Finally, disregarding the fact that the projection data come from different planes based on the idea of the Feldkamp–Davis–Kress algorithm, an approximate analytical reconstruction algorithm is derived based on the geometric relationships between the original coordinate system and the detector coordinates. The effectiveness of our method is demonstrated through simulations and real data experiments. The results demonstrate that the proposed method mitigates the superimposition artifacts and enhances the fine structural details to a certain extent compared to the CL-filtered backprojection method, while preserving the object boundaries.
- 1 July 2025
- Published by IOP Publishing in Inverse Problems
- Vol. 41 (7) , 075010
An approximate analytical reconstruction method in inverse problems of cone-beam rotary computed laminography
Computed tomography is a highly effective inspection methodology for non-destructive testing, however, it faces challenges with objects that have a significant aspect ratio. In such scenarios, computed laminography (CL) serves as a viable alternative. The unique geometric configuration of cone-beam rotary CL makes the classical FDK reconstruction algorithm unsuitable. To address this inverse problem, we proposed an approximate analytical reconstruction method inspired by the core idea of the FDK algorithm. Firstly, we addressed the cone-beam rotary CL reconstruction problem by approximating it as a series of fan-beam reconstruction tasks, and deriving the geometric relationships between the original coordinate system and the fan-beam coordinates. Secondly, the fan-beam reconstruction formula within the fan-beam coordinate system is derived. Finally, disregarding the fact that the projection data come from different planes based on the idea of the Feldkamp–Davis–Kress algorithm, an approximate analytical reconstruction algorithm is derived based on the geometric relationships between the original coordinate system and the detector coordinates. The effectiveness of our method is demonstrated through simulations and real data experiments. The results demonstrate that the proposed method mitigates the superimposition artifacts and enhances the fine structural details to a certain extent compared to the CL-filtered backprojection method, while preserving the object boundaries.
- 24 April 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (9) , 095019
An interactive method based on multi-objective optimization for limited-angle CT reconstruction
Objective. Limited-angle x-ray computed tomography (CT) is a typical ill-posed inverse problem, leading to artifacts in the reconstructed image due to the incomplete projection data. Most iteration CT reconstruction methods involve optimization for a single object. This paper explores a multi-objective optimization model and an interactive method based on multi-objective optimization to suppress the artifacts of limited-angle CT. Approach. The model includes two objective functions on the dual domain within the data consistency constraint. In the interactive method, the structural similarity index measure (SSIM) is regarded as the value function of the decision maker (DM) firstly. Secondly, the DM arranges the objective functions of the multi-objective optimization model to be optimized according to their absolute importance. Finally, the SSIM and the simulated annealing (SA) method help the DM choose the desirable reconstruction image by improving the SSIM value during the iteration process. Main results. Simulation and real data experiments demonstrate that the artifacts can be suppressed by the proposed method, and the results were superior to those reconstructed by the other three reconstruction methods in preserving the edge structure of the image. Significance. The proposed interactive method based on multi-objective optimization shows some potential advantages over classical single object optimization methods.
- 24 April 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (9) , 095019
An interactive method based on multi-objective optimization for limited-angle CT reconstruction
Objective. Limited-angle x-ray computed tomography (CT) is a typical ill-posed inverse problem, leading to artifacts in the reconstructed image due to the incomplete projection data. Most iteration CT reconstruction methods involve optimization for a single object. This paper explores a multi-objective optimization model and an interactive method based on multi-objective optimization to suppress the artifacts of limited-angle CT. Approach. The model includes two objective functions on the dual domain within the data consistency constraint. In the interactive method, the structural similarity index measure (SSIM) is regarded as the value function of the decision maker (DM) firstly. Secondly, the DM arranges the objective functions of the multi-objective optimization model to be optimized according to their absolute importance. Finally, the SSIM and the simulated annealing (SA) method help the DM choose the desirable reconstruction image by improving the SSIM value during the iteration process. Main results. Simulation and real data experiments demonstrate that the artifacts can be suppressed by the proposed method, and the results were superior to those reconstructed by the other three reconstruction methods in preserving the edge structure of the image. Significance. The proposed interactive method based on multi-objective optimization shows some potential advantages over classical single object optimization methods.
- 30 January 2024
- Published by Walter de Gruyter GmbH in Journal of Inverse and Ill-posed Problems
- Vol. 32 (5) , 927-938
CT image restoration method via total variation and L 0 smoothing filter
In X-ray CT imaging, there are some cases where the obtained CT images have serious ring artifacts and noise, and these degraded CT images seriously affect the quality of clinical diagnosis. Thus, developing an effective method that can simultaneously suppress ring artifacts and noise is of great importance. Total variation (TV) is a famous prior regularization for image denoising in the image processing field, however, for degraded CT images, it can suppress the noise but fail to reduce the ring artifacts. To address this issue, the smoothing filter is incorporated with TV prior for CT ring artifacts and noise removal problem where the problem is transformed into several optimization sub-problems which are iteratively solved. The experiments demonstrate that the ring artifacts and noise presented in the CT image can be effectively suppressed by the proposed method and meanwhile the detailed features such as edge structure can be well preserved. As the superiority of TV and smoothing filters are fully utilized, the performance of the proposed method is better than the existing methods such as the TV-based method and -based method.- 30 January 2024
- Published by Walter de Gruyter GmbH in Journal of Inverse and Ill-posed Problems
- Vol. 32 (5) , 927-938
CT image restoration method via total variation and L 0 smoothing filter
In X-ray CT imaging, there are some cases where the obtained CT images have serious ring artifacts and noise, and these degraded CT images seriously affect the quality of clinical diagnosis. Thus, developing an effective method that can simultaneously suppress ring artifacts and noise is of great importance. Total variation (TV) is a famous prior regularization for image denoising in the image processing field, however, for degraded CT images, it can suppress the noise but fail to reduce the ring artifacts. To address this issue, the smoothing filter is incorporated with TV prior for CT ring artifacts and noise removal problem where the problem is transformed into several optimization sub-problems which are iteratively solved. The experiments demonstrate that the ring artifacts and noise presented in the CT image can be effectively suppressed by the proposed method and meanwhile the detailed features such as edge structure can be well preserved. As the superiority of TV and smoothing filters are fully utilized, the performance of the proposed method is better than the existing methods such as the TV-based method and -based method.- 11 May 2023
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 31 (3) , 463-482
RICT: Rotating image computed tomography with a one-to-one reversible image rotation algorithm
BACKGROUND: The Mueller, Siddon and Joseph weighting algorithms are frequently used for projection and back-projection, which are relatively complicated when they are implemented in computer code. OBJECTIVE: This study aims to reduce the actual complexity of the projection and back-projection. METHODS: First, we neglect the exact shape of the pixel, so that its shadow is a rectangle projecting precisely to a detector bin, which implies that all the pixel weights are exactly 1 for each ray through them, otherwise are exactly 0. Next, a one-to-one reversible image rotation algorithm (RIRA) is proposed to compute the projection and back-projection, where two one-to-one mapping lists namely, U and V, are used to store the coordinates of a rotated pixel and its corresponding new coordinates, respectively. For each 2D projection, the projection is simply the column sum in each orientation according to the lists U and V. For each 2D back-projection, it is simply to arrange the projection to the corresponding column element according to the lists U and V. Thus, there is no need for an interpolation in the projection and back-projection. Last, a rotating image computed tomography (RICT) based on RIRA is proposed to reconstruct the image. RESULTS: Experiments show the RICT reconstructs a good image that is close to the result of filtered back-projection (FBP) method according to the RMSE, PSNR and MSSIM values. What’s more, our weight, projection and back-projection are much easier to be implemented in computer code than the FBP method. CONCLUSION: This study demonstrates that the RIRA method has potential to be used to simplify many computed tomography image reconstruction algorithms.
- 11 May 2023
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 31 (3) , 463-482
RICT: Rotating image computed tomography with a one-to-one reversible image rotation algorithm
BACKGROUND: The Mueller, Siddon and Joseph weighting algorithms are frequently used for projection and back-projection, which are relatively complicated when they are implemented in computer code. OBJECTIVE: This study aims to reduce the actual complexity of the projection and back-projection. METHODS: First, we neglect the exact shape of the pixel, so that its shadow is a rectangle projecting precisely to a detector bin, which implies that all the pixel weights are exactly 1 for each ray through them, otherwise are exactly 0. Next, a one-to-one reversible image rotation algorithm (RIRA) is proposed to compute the projection and back-projection, where two one-to-one mapping lists namely, U and V, are used to store the coordinates of a rotated pixel and its corresponding new coordinates, respectively. For each 2D projection, the projection is simply the column sum in each orientation according to the lists U and V. For each 2D back-projection, it is simply to arrange the projection to the corresponding column element according to the lists U and V. Thus, there is no need for an interpolation in the projection and back-projection. Last, a rotating image computed tomography (RICT) based on RIRA is proposed to reconstruct the image. RESULTS: Experiments show the RICT reconstructs a good image that is close to the result of filtered back-projection (FBP) method according to the RMSE, PSNR and MSSIM values. What’s more, our weight, projection and back-projection are much easier to be implemented in computer code than the FBP method. CONCLUSION: This study demonstrates that the RIRA method has potential to be used to simplify many computed tomography image reconstruction algorithms.