Hiram G Bezerra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hiram G Bezerra has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Akiko Maehara
Columbia University Irving Medical Center
1 shared publication Balbir Singh
Max Super Specialty Hospital , Saket, New Delhi
1 shared publication- Carlo Trani
Catholic University of the Sacred Heart
1 shared publication - Daniela Crousillat
Division of Cardiovascular Sciences, Department of Medicine and Obstetrics and Gynecology, Morsani College of Medicine, University of South Florida, Tampa, FL, USA
1 shared publication - David Manuel Leistner
University Heart Centre Frankfurt, University Hospital Frankfurt
1 shared publication - Donald L. Quimby
Interventional Cardiology Center, Tampa General Hospital, Tampa, Florida
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 28 August 2024
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 45 (43) , 4630-4643
Optical coherence tomography predictors of clinical outcomes after stent implantation: the ILUMIEN IV trial
Observational registries have suggested that optical coherence tomography (OCT) imaging-derived parameters may predict adverse events after drug-eluting stent (DES) implantation. The present analysis sought to determine the OCT predictors of clinical outcomes from the large-scale ILUMIEN IV trial. ILUMIEN IV was a prospective, single-blind trial of 2487 patients with diabetes or high-risk lesions randomized to OCT-guided versus angiography-guided DES implantation. All patients underwent final OCT imaging (blinded in the angiography-guided arm). From more than 20 candidates, the independent OCT predictors of 2-year target lesion failure (TLF; the primary endpoint), cardiac death or target-vessel myocardial infarction (TV-MI), ischaemia-driven target lesion revascularization (ID-TLR), and stent thrombosis were analysed by multivariable Cox proportional hazard regression in single treated lesions. A total of 2128 patients had a single treated lesion with core laboratory-analysed final OCT. The 2-year Kaplan–Meier rates of TLF, cardiac death or TV-MI, ID-TLR, and stent thrombosis were 6.3% (n = 130), 3.3% (n = 68), 4.3% (n = 87), and 0.9% (n = 18), respectively. The independent predictors of 2-year TLF were a smaller minimal stent area (per 1 mm2 increase: hazard ratio 0.76, 95% confidence interval 0.68–0.89, P < .0001) and proximal edge dissection (hazard ratio 1.77, 95% confidence interval 1.20–2.62, P = .004). The independent predictors of cardiac death or TV-MI were smaller minimal stent area and longer stent length; of ID-TLR were smaller intra-stent flow area and proximal edge dissection; and of stent thrombosis was smaller minimal stent expansion. In the ILUMIEN IV trial, the most important OCT-derived post-DES predictors of both safety and effectiveness outcomes were parameters related to stent area, expansion and flow, proximal edge dissection, and stent length. The independent optical coherence tomography predictors of clinical outcomes in 2128 patients with a single treated lesion in the ILUMIEN IV trial are shown here. Minimal stent area is defined as the smallest stent area within the contiguous stent segment. Minimal stent expansion is defined as the minimal stent area divided by the average of proximal and distal reference lumen areas × 100. Intra-stent flow (lumen) area is defined as stent area minus intra-stent plaque protrusion or thrombus area. HR, hazard ratio; ID-TLR, ischaemia-driven target lesion revascularization; MSA, minimal stent area; MSE, minimal stent expansion; OCT, optical coherence tomography; TLF, target lesion failure; TV-MI, target-vessel myocardial infarction
- 28 August 2024
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 45 (43) , 4630-4643
Top Cited PapersOpen AccessOptical coherence tomography predictors of clinical outcomes after stent implantation: the ILUMIEN IV trial
Observational registries have suggested that optical coherence tomography (OCT) imaging-derived parameters may predict adverse events after drug-eluting stent (DES) implantation. The present analysis sought to determine the OCT predictors of clinical outcomes from the large-scale ILUMIEN IV trial. ILUMIEN IV was a prospective, single-blind trial of 2487 patients with diabetes or high-risk lesions randomized to OCT-guided versus angiography-guided DES implantation. All patients underwent final OCT imaging (blinded in the angiography-guided arm). From more than 20 candidates, the independent OCT predictors of 2-year target lesion failure (TLF; the primary endpoint), cardiac death or target-vessel myocardial infarction (TV-MI), ischaemia-driven target lesion revascularization (ID-TLR), and stent thrombosis were analysed by multivariable Cox proportional hazard regression in single treated lesions. A total of 2128 patients had a single treated lesion with core laboratory-analysed final OCT. The 2-year Kaplan–Meier rates of TLF, cardiac death or TV-MI, ID-TLR, and stent thrombosis were 6.3% (n = 130), 3.3% (n = 68), 4.3% (n = 87), and 0.9% (n = 18), respectively. The independent predictors of 2-year TLF were a smaller minimal stent area (per 1 mm2 increase: hazard ratio 0.76, 95% confidence interval 0.68–0.89, P < .0001) and proximal edge dissection (hazard ratio 1.77, 95% confidence interval 1.20–2.62, P = .004). The independent predictors of cardiac death or TV-MI were smaller minimal stent area and longer stent length; of ID-TLR were smaller intra-stent flow area and proximal edge dissection; and of stent thrombosis was smaller minimal stent expansion. In the ILUMIEN IV trial, the most important OCT-derived post-DES predictors of both safety and effectiveness outcomes were parameters related to stent area, expansion and flow, proximal edge dissection, and stent length. The independent optical coherence tomography predictors of clinical outcomes in 2128 patients with a single treated lesion in the ILUMIEN IV trial are shown here. Minimal stent area is defined as the smallest stent area within the contiguous stent segment. Minimal stent expansion is defined as the minimal stent area divided by the average of proximal and distal reference lumen areas × 100. Intra-stent flow (lumen) area is defined as stent area minus intra-stent plaque protrusion or thrombus area. HR, hazard ratio; ID-TLR, ischaemia-driven target lesion revascularization; MSA, minimal stent area; MSE, minimal stent expansion; OCT, optical coherence tomography; TLF, target lesion failure; TV-MI, target-vessel myocardial infarction
- Open Access
- 23 January 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 8 (2) , ytae033
Early use of intrapartum intra-aortic balloon pump support for haemodynamic stabilization of peripartum and anthracycline-induced cardiomyopathy: a case report
Background: Prior exposure to cardiotoxic cancer therapies has been associated with an increased risk of peripartum cardiomyopathy (PPCM). The management of PPCM in this population remains a clinical challenge. Few studies have explored the use of mechanical circulatory support in PPCM. We present a case of early implementation of intra-aortic balloon pump (IABP) therapy for acute stabilization and intrapartum support of PPCM.Case summary: A 36-year-old G4P2103 (4th pregnancy, two full-term, one premature birth, 0 abortions, and three living children) woman at 26 weeks and 5 days gestation with history of combined peripartum and anthracycline-induced cardiomyopathy [previously left ventricular ejection fraction (LVEF) 10–15% and recently 40–45%] presented with acute decompensated heart failure. Her clinical status deteriorated with a drop in LVEF to 15–20% with a significant increase in pulmonary pressures and worsening mitral regurgitation. A multidisciplinary decision with the cardio-obstetrics team was made to place a pulmonary artery catheter for invasive haemodynamic monitoring and IABP insertion prior to delivery. Intra-aortic balloon pump support had a profound immediate decrease in her systemic and pulmonary vascular resistance allowing for a successful repeat caesarean delivery. Her haemodynamics remained stable after IABP removal and pulmonary pressures improved. She was discharged one week following her delivery on guideline-directed medical therapy.Discussion: Our case highlights the use of prophylactic intrapartum IABP in combined anthracycline-induced and PPCM and begins to explore its safety and efficacy in this high-risk patient population.
- 23 January 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 8 (2) , ytae033
Open AccessEarly use of intrapartum intra-aortic balloon pump support for haemodynamic stabilization of peripartum and anthracycline-induced cardiomyopathy: a case report
Background: Prior exposure to cardiotoxic cancer therapies has been associated with an increased risk of peripartum cardiomyopathy (PPCM). The management of PPCM in this population remains a clinical challenge. Few studies have explored the use of mechanical circulatory support in PPCM. We present a case of early implementation of intra-aortic balloon pump (IABP) therapy for acute stabilization and intrapartum support of PPCM.Case summary: A 36-year-old G4P2103 (4th pregnancy, two full-term, one premature birth, 0 abortions, and three living children) woman at 26 weeks and 5 days gestation with history of combined peripartum and anthracycline-induced cardiomyopathy [previously left ventricular ejection fraction (LVEF) 10–15% and recently 40–45%] presented with acute decompensated heart failure. Her clinical status deteriorated with a drop in LVEF to 15–20% with a significant increase in pulmonary pressures and worsening mitral regurgitation. A multidisciplinary decision with the cardio-obstetrics team was made to place a pulmonary artery catheter for invasive haemodynamic monitoring and IABP insertion prior to delivery. Intra-aortic balloon pump support had a profound immediate decrease in her systemic and pulmonary vascular resistance allowing for a successful repeat caesarean delivery. Her haemodynamics remained stable after IABP removal and pulmonary pressures improved. She was discharged one week following her delivery on guideline-directed medical therapy.Discussion: Our case highlights the use of prophylactic intrapartum IABP in combined anthracycline-induced and PPCM and begins to explore its safety and efficacy in this high-risk patient population.