Christian W. Kündig
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christian W. Kündig has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Gergely David
Spinal Cord Injury Center, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
6 shared publications - Patrick Freund
Spinal Cord Injury Center, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
5 shared publications - Martina Daniela Liechti
Department of Neuro-Urology, Balgrist University Hospital, University of Zürich, Zürich, Switzerland
3 shared publications - Silvan Büeler
Department of Neuro-Urology, Balgrist University Hospital, University of Zürich, Zürich, Switzerland
3 shared publications - Alexandra Tinnermann
Institute of Systems Neuroscience, University Medical Center Hamburg-Eppendorf, Germany
2 shared publications - Ali Khatibi
Department of Psychology, University of Bath, Bath, UK
2 shared publications
Latest Publications
- Open Access
- 10 November 2026
- Published by MIT Press in Imaging Neuroscience
Functional magnetic resonance imaging of the lumbosacral spinal cord during transcutaneous tibial nerve stimulation: feasibility and test-retest reliability
We investigated the neural responses evoked by unilateral transcutaneous tibial nerve stimulation (TTNS) in the human lumbosacral spinal cord using blood-oxygen-level-dependent (BOLD) functional MRI. We evaluated study design parameters including the impact of sample size, number of runs per subject, and run duration on the robustness and reproducibility of task-related BOLD responses acquired in 25 healthy participants across two sessions separated by one week. We used block-designed electrical stimulation of the right tibial nerve at supra-motor threshold. TTNS elicited lateralized BOLD responses predominantly in the ipsilateral dorsal horns, consistent with the sensory input from tibial nerve afferents and proprioceptive feedback from stimulation-induced muscle contractions. Along the rostrocaudal axis, two clusters of activation were identified, corresponding to the tibial nerve and likely coactivation of the saphenous nerve. Group-level analyses revealed that robust and reproducible activation maps could be achieved with approximately 20 participants, whereas single-subject maps displayed substantial variability, emphasizing the importance of adequate sample size. Habituation of BOLD responses across repeated stimulation runs limited the benefits of longer acquisitions. In the initial session, gains in statistical sensitivity diminished beyond approximately 24 minutes, suggesting a practical acquisition duration for future studies using this paradigm. Finally, test-retest comparisons over a one-week interval showed reduced activation in the second session, consistent with adaptation-related changes or potential neuromodulatory effects. Taken together, these findings provide a comprehensive characterization of TTNS-evoked lumbosacral spinal cord activity and establish methodological considerations for optimizing spinal fMRI study design, including sample size and run duration. This work lays the foundation for future investigations into the functional organization of the human spinal cord and its modulation by non-invasive electrical stimulation.
- 10 November 2026
- Published by MIT Press in Imaging Neuroscience
Open AccessFunctional magnetic resonance imaging of the lumbosacral spinal cord during transcutaneous tibial nerve stimulation: feasibility and test-retest reliability
We investigated the neural responses evoked by unilateral transcutaneous tibial nerve stimulation (TTNS) in the human lumbosacral spinal cord using blood-oxygen-level-dependent (BOLD) functional MRI. We evaluated study design parameters including the impact of sample size, number of runs per subject, and run duration on the robustness and reproducibility of task-related BOLD responses acquired in 25 healthy participants across two sessions separated by one week. We used block-designed electrical stimulation of the right tibial nerve at supra-motor threshold. TTNS elicited lateralized BOLD responses predominantly in the ipsilateral dorsal horns, consistent with the sensory input from tibial nerve afferents and proprioceptive feedback from stimulation-induced muscle contractions. Along the rostrocaudal axis, two clusters of activation were identified, corresponding to the tibial nerve and likely coactivation of the saphenous nerve. Group-level analyses revealed that robust and reproducible activation maps could be achieved with approximately 20 participants, whereas single-subject maps displayed substantial variability, emphasizing the importance of adequate sample size. Habituation of BOLD responses across repeated stimulation runs limited the benefits of longer acquisitions. In the initial session, gains in statistical sensitivity diminished beyond approximately 24 minutes, suggesting a practical acquisition duration for future studies using this paradigm. Finally, test-retest comparisons over a one-week interval showed reduced activation in the second session, consistent with adaptation-related changes or potential neuromodulatory effects. Taken together, these findings provide a comprehensive characterization of TTNS-evoked lumbosacral spinal cord activity and establish methodological considerations for optimizing spinal fMRI study design, including sample size and run duration. This work lays the foundation for future investigations into the functional organization of the human spinal cord and its modulation by non-invasive electrical stimulation.
- Open Access
- 3 August 2026
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Navigator readouts with optimized processing improve spinal cord and gray matter segmentability in multi-echo gradient-echo imaging
Multi-echo gradient-echo (ME-GRE) acquisitions of the spinal cord (SC) are highly susceptible to breathing-induced magnetic field fluctuations arising from the proximity of the lungs, often resulting in ghosting artifacts and signal loss. A navigator readout can be employed to monitor and correct for these field variations; however, conventional navigator processing methods frequently fail in the SC due to its small size and distinct anatomy. Here, we evaluate the impact of a recently introduced, SC-specific navigator processing approach on SC and gray matter (GM) segmentability. ME-GRE images were acquired at 3T during free breathing in ten healthy volunteers, covering the cervical, thoracic, and lumbosacral spinal cord. Data were collected both with and without a centerline navigator readout. Acquisitions without navigators included five imaging echoes, whereas those with navigators comprised four imaging echoes followed by an additional readout of the k-space centerline (the “navigator echo”). The navigator readout was processed using a recently introduced method optimized for the SC. The effect of the optimized navigator correction was evaluated by contrast-to-noise ratio (CNR), qualitative ratings of SC and GM segmentability, and the performance of automatic segmentation algorithms. Compared with acquisitions without navigators, optimized navigator correction significantly improved quantitative image quality metrics, particularly GM-white matter CNR at the C7-T1 and T7-T8 vertebral levels and across the lumbosacral cord. Regarding SC and GM segmentability, raters preferred images with navigators over uncorrected images at nearly all spinal cord levels, with the strongest effect observed for GM segmentability in the lumbosacral cord. Although overall automatic segmentation performance was comparable between acquisition types, automatic GM segmentation failed at the lumbosacral cord in the presence of severe artifacts in acquisitions without navigators, while remaining robust in the corresponding navigator-corrected images. In conclusion, navigator processing optimized for SC imaging improves image quality and segmentability in ME-GRE acquisitions, making this technique attractive for both clinical and research applications.
- 3 August 2026
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Open AccessNavigator readouts with optimized processing improve spinal cord and gray matter segmentability in multi-echo gradient-echo imaging
Multi-echo gradient-echo (ME-GRE) acquisitions of the spinal cord (SC) are highly susceptible to breathing-induced magnetic field fluctuations arising from the proximity of the lungs, often resulting in ghosting artifacts and signal loss. A navigator readout can be employed to monitor and correct for these field variations; however, conventional navigator processing methods frequently fail in the SC due to its small size and distinct anatomy. Here, we evaluate the impact of a recently introduced, SC-specific navigator processing approach on SC and gray matter (GM) segmentability. ME-GRE images were acquired at 3T during free breathing in ten healthy volunteers, covering the cervical, thoracic, and lumbosacral spinal cord. Data were collected both with and without a centerline navigator readout. Acquisitions without navigators included five imaging echoes, whereas those with navigators comprised four imaging echoes followed by an additional readout of the k-space centerline (the “navigator echo”). The navigator readout was processed using a recently introduced method optimized for the SC. The effect of the optimized navigator correction was evaluated by contrast-to-noise ratio (CNR), qualitative ratings of SC and GM segmentability, and the performance of automatic segmentation algorithms. Compared with acquisitions without navigators, optimized navigator correction significantly improved quantitative image quality metrics, particularly GM-white matter CNR at the C7-T1 and T7-T8 vertebral levels and across the lumbosacral cord. Regarding SC and GM segmentability, raters preferred images with navigators over uncorrected images at nearly all spinal cord levels, with the strongest effect observed for GM segmentability in the lumbosacral cord. Although overall automatic segmentation performance was comparable between acquisition types, automatic GM segmentation failed at the lumbosacral cord in the presence of severe artifacts in acquisitions without navigators, while remaining robust in the corresponding navigator-corrected images. In conclusion, navigator processing optimized for SC imaging improves image quality and segmentability in ME-GRE acquisitions, making this technique attractive for both clinical and research applications.
- Open Access
- 21 July 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
EPISeg: Automated segmentation of the spinal cord on echo planar images using open-access multi-center data
Functional magnetic resonance imaging (fMRI) of the spinal cord is relevant for studying sensation, movement, and autonomic function. Preprocessing of spinal cord fMRI data involves segmentation of the spinal cord on gradient-echo echo planar imaging (EPI) images. Current automated segmentation methods do not work well on these data, due to the low spatial resolution, susceptibility artifacts causing distortions and signal drop-out, ghosting, and motion-related artifacts. Consequently, this segmentation task demands a considerable amount of manual effort which takes time and is prone to user bias. In this work, we (i) gathered a multi-center dataset of spinal cord gradient-echo EPI with ground-truth segmentations and shared it on OpenNeuro https://openneuro.org/datasets/ds005143/versions/1.3.0, and (ii) developed a deep learning-based model, EPISeg, for the automatic segmentation of the spinal cord on gradient-echo EPI data. We observe a significant improvement in terms of segmentation quality compared to other available spinal cord segmentation models. Our model is resilient to different acquisition protocols as well as commonly observed artifacts in fMRI data. The training code is available at https://github.com/sct-pipeline/fmri-segmentation/, and the model has been integrated into the Spinal Cord Toolbox as a command-line tool.
- 21 July 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Open AccessEPISeg: Automated segmentation of the spinal cord on echo planar images using open-access multi-center data
Functional magnetic resonance imaging (fMRI) of the spinal cord is relevant for studying sensation, movement, and autonomic function. Preprocessing of spinal cord fMRI data involves segmentation of the spinal cord on gradient-echo echo planar imaging (EPI) images. Current automated segmentation methods do not work well on these data, due to the low spatial resolution, susceptibility artifacts causing distortions and signal drop-out, ghosting, and motion-related artifacts. Consequently, this segmentation task demands a considerable amount of manual effort which takes time and is prone to user bias. In this work, we (i) gathered a multi-center dataset of spinal cord gradient-echo EPI with ground-truth segmentations and shared it on OpenNeuro https://openneuro.org/datasets/ds005143/versions/1.3.0, and (ii) developed a deep learning-based model, EPISeg, for the automatic segmentation of the spinal cord on gradient-echo EPI data. We observe a significant improvement in terms of segmentation quality compared to other available spinal cord segmentation models. Our model is resilient to different acquisition protocols as well as commonly observed artifacts in fMRI data. The training code is available at https://github.com/sct-pipeline/fmri-segmentation/, and the model has been integrated into the Spinal Cord Toolbox as a command-line tool.
- Open Access
- 27 January 2025
- Published by Wiley in Annals of Clinical and Translational Neurology
- Vol. 12 (3) , 523-537
Remote neurodegeneration in the lumbosacral cord one month after spinal cord injury: a cross‐sectional MRI study
Objective: To characterize structural integrity of the lumbosacral enlargement and conus medullaris within one month after spinal cord injury (SCI).Methods: Lumbosacral cord MRI data were acquired in patients with sudden onset (<7 days) SCI at the cervical or thoracic level approximately one month after injury and in healthy controls. Tissue integrity and loss were evaluated through diffusion tensor (DTI) and T2*‐weighted imaging (cross‐sectional area [CSA] measurements). Associations with the degree of neurological impairment were assessed using linear mixed‐effects models.Results: Twenty‐one patients with SCI showed lower white matter (WM) fractional anisotropy (FA) (≤−13.3%) and higher WM radial diffusivity (≤14.6%) compared to 27 healthy controls. Differences were most pronounced in the lateral columns of WM. CSA measurements revealed no group differences. For the lateral columns, lower FA values were associated with lower motor scores and lower amplitudes of motor evoked potentials. For the dorsal columns, lower FA values were associated with lower amplitudes of somatosensory evoked potentials from the lower extremities.Interpretation: One month after SCI, first signs of WM degeneration were apparent, without indication of tissue loss. The more pronounced differences observed in the lateral column could be attributed to anterograde degeneration of the motor tracts. The variability among DTI measurements remote from the lesion site can be partially explained by the degree of the SCI‐induced neurological impairment. Together with previous studies, our findings indicate that impaired tissue integrity precedes tissue loss. The presented techniques have potential applications in monitoring the progression of various neurological diseases.
- 27 January 2025
- Published by Wiley in Annals of Clinical and Translational Neurology
- Vol. 12 (3) , 523-537
Open AccessRemote neurodegeneration in the lumbosacral cord one month after spinal cord injury: a cross‐sectional MRI study
Objective: To characterize structural integrity of the lumbosacral enlargement and conus medullaris within one month after spinal cord injury (SCI).Methods: Lumbosacral cord MRI data were acquired in patients with sudden onset (<7 days) SCI at the cervical or thoracic level approximately one month after injury and in healthy controls. Tissue integrity and loss were evaluated through diffusion tensor (DTI) and T2*‐weighted imaging (cross‐sectional area [CSA] measurements). Associations with the degree of neurological impairment were assessed using linear mixed‐effects models.Results: Twenty‐one patients with SCI showed lower white matter (WM) fractional anisotropy (FA) (≤−13.3%) and higher WM radial diffusivity (≤14.6%) compared to 27 healthy controls. Differences were most pronounced in the lateral columns of WM. CSA measurements revealed no group differences. For the lateral columns, lower FA values were associated with lower motor scores and lower amplitudes of motor evoked potentials. For the dorsal columns, lower FA values were associated with lower amplitudes of somatosensory evoked potentials from the lower extremities.Interpretation: One month after SCI, first signs of WM degeneration were apparent, without indication of tissue loss. The more pronounced differences observed in the lateral column could be attributed to anterograde degeneration of the motor tracts. The variability among DTI measurements remote from the lesion site can be partially explained by the degree of the SCI‐induced neurological impairment. Together with previous studies, our findings indicate that impaired tissue integrity precedes tissue loss. The presented techniques have potential applications in monitoring the progression of various neurological diseases.
- Open Access
EPISeg: Automated segmentation of the spinal cord on echo planar images using open-access multi-center data
Functional magnetic resonance imaging (fMRI) of the spinal cord is relevant for studying sensation, movement, and autonomic function. Preprocessing of spinal cord fMRI data involves segmentation of the spinal cord on gradient-echo echo planar imaging (EPI) images. Current automated segmentation methods do not work well on these data, due to the low spatial resolution, susceptibility artifacts causing distortions and signal drop-out, ghosting, and motion-related artifacts. Consequently, this segmentation task demands a considerable amount of manual effort which takes time and is prone to user bias. In this work, we (i) gathered a multi-center dataset of spinal cord gradient-echo EPI with ground-truth segmentations and shared it on OpenNeuro https://openneuro.org/datasets/ds005143/versions/1.3.0 , and (ii) developed a deep learning-based model, EPISeg, for the automatic segmentation of the spinal cord on gradient-echo EPI data. We observe a significant improvement in terms of segmentation quality compared to other available spinal cord segmentation models. Our model is resilient to different acquisition protocols as well as commonly observed artifacts in fMRI data. The training code is available at https://github.com/sct-pipeline/fmri-segmentation/ , and the model has been integrated into the Spinal Cord Toolbox as a command-line tool.
Open AccessEPISeg: Automated segmentation of the spinal cord on echo planar images using open-access multi-center data
Functional magnetic resonance imaging (fMRI) of the spinal cord is relevant for studying sensation, movement, and autonomic function. Preprocessing of spinal cord fMRI data involves segmentation of the spinal cord on gradient-echo echo planar imaging (EPI) images. Current automated segmentation methods do not work well on these data, due to the low spatial resolution, susceptibility artifacts causing distortions and signal drop-out, ghosting, and motion-related artifacts. Consequently, this segmentation task demands a considerable amount of manual effort which takes time and is prone to user bias. In this work, we (i) gathered a multi-center dataset of spinal cord gradient-echo EPI with ground-truth segmentations and shared it on OpenNeuro https://openneuro.org/datasets/ds005143/versions/1.3.0 , and (ii) developed a deep learning-based model, EPISeg, for the automatic segmentation of the spinal cord on gradient-echo EPI data. We observe a significant improvement in terms of segmentation quality compared to other available spinal cord segmentation models. Our model is resilient to different acquisition protocols as well as commonly observed artifacts in fMRI data. The training code is available at https://github.com/sct-pipeline/fmri-segmentation/ , and the model has been integrated into the Spinal Cord Toolbox as a command-line tool.
- Open Access
Functional magnetic resonance imaging of the lumbosacral cord during a lower extremity motor task
Blood-oxygen-level dependent (BOLD) functional magnetic resonance imaging (fMRI) can be used to map neuronal function in the cervical cord, yet conclusive evidence supporting its applicability in the lumbosacral cord is still lacking. This study aimed to (i) demonstrate the feasibility of BOLD fMRI in mapping neuronal activation in the lumbosacral cord during a unilateral lower extremity motor task and (ii) investigate the impact of echo time (TE) on the BOLD effect size. Twelve healthy volunteers underwent BOLD fMRI using four reduced-field-of-view single-shot gradient-echo echo planar imaging sequences, all with the same geometry but different TE values ranging from 20 to 42 ms. Each sequence was employed to acquire a single 6-minute rest run and two 10-minute task runs, which included alternating 15-second blocks of rest and unilateral ankle dorsi- and plantar flexion. We detected lateralized task-related neuronal activation at neurological levels S4 to L1, centered at the ipsilateral (right) ventral spinal cord but also extending into the ipsilateral dorsal spinal cord. This pattern of activation is consistent with our current understanding of spinal cord organization, wherein lower motor neurons are located in the ventral gray matter horn, while sensory neurons of the proprioceptive pathway, activated during the movement, are located in the dorsal horns. At the subject level, BOLD activation showed considerable variability but was lateralized in all participants. The highest BOLD effect size within the ipsilateral ventral spinal cord was observed at TE=42 ms. Sequences with a shorter TE (20 and 28 ms) also detected activation in the medioventral part of the spinal cord, likely representing a large vein effect. In summary, our results demonstrate the feasibility of detecting neuronal activation in the lumbosacral cord induced by voluntary lower limb movements. BOLD fMRI in the lumbosacral cord has significant implications for assessing motor function and its alterations in disease or after spinal cord injury.
Open AccessFunctional magnetic resonance imaging of the lumbosacral cord during a lower extremity motor task
Blood-oxygen-level dependent (BOLD) functional magnetic resonance imaging (fMRI) can be used to map neuronal function in the cervical cord, yet conclusive evidence supporting its applicability in the lumbosacral cord is still lacking. This study aimed to (i) demonstrate the feasibility of BOLD fMRI in mapping neuronal activation in the lumbosacral cord during a unilateral lower extremity motor task and (ii) investigate the impact of echo time (TE) on the BOLD effect size. Twelve healthy volunteers underwent BOLD fMRI using four reduced-field-of-view single-shot gradient-echo echo planar imaging sequences, all with the same geometry but different TE values ranging from 20 to 42 ms. Each sequence was employed to acquire a single 6-minute rest run and two 10-minute task runs, which included alternating 15-second blocks of rest and unilateral ankle dorsi- and plantar flexion. We detected lateralized task-related neuronal activation at neurological levels S4 to L1, centered at the ipsilateral (right) ventral spinal cord but also extending into the ipsilateral dorsal spinal cord. This pattern of activation is consistent with our current understanding of spinal cord organization, wherein lower motor neurons are located in the ventral gray matter horn, while sensory neurons of the proprioceptive pathway, activated during the movement, are located in the dorsal horns. At the subject level, BOLD activation showed considerable variability but was lateralized in all participants. The highest BOLD effect size within the ipsilateral ventral spinal cord was observed at TE=42 ms. Sequences with a shorter TE (20 and 28 ms) also detected activation in the medioventral part of the spinal cord, likely representing a large vein effect. In summary, our results demonstrate the feasibility of detecting neuronal activation in the lumbosacral cord induced by voluntary lower limb movements. BOLD fMRI in the lumbosacral cord has significant implications for assessing motor function and its alterations in disease or after spinal cord injury.