FAFranziska C. S. Altorfer

Franziska C. S. Altorfer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Franziska C. S. Altorfer has a total of 94 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Mitigating radiation in robotic-assisted sacropelvic screw placement using 3D magnetic resonance imaging

    by Giuseppe Loggia, Fedan Avrumova, Marco D. Burkhard, Michael J. Kelly, Franziska C.S. Altorfer, Joseph Iii C. Babrowicz, Allison S. Lowe, Jiaqi Zhu, Ek T. Tan, Joseph L. Chazen, et al.

    Objective: To evaluate the feasibility and accuracy of robotic-assisted (RA) sacropelvic screw placement (SPSP) using three-dimensional magnetic resonance imaging (3D MRI) for preoperative planning and robotic registration. Summary of background data: SPSP is a critical component of spinal fixation but is subject to trajectory deviations, and radiation exposure with fluoroscopic or computed tomography (CT)-based navigation. CT-like 3D MRI-based navigation provides radiation-free preoperative imaging, but its integration with RA systems remains unexplored in SPSP. Methods: Eight human cadavers underwent RA SPSP using MRI-based preoperative planning, including the placement of S1 pedicle screws, S1-alar-iliac (AI) screws, and S2-AI screws bilaterally. Accuracy was measured as deviation between planned vs. achieved trajectories by postoperative CT analysis. This was quantified through direct measurements and subsequently categorized using the Gertzbein-Robbins Scale (GRS). Results: A total of 48 screws were placed using 3D MRI-based RA navigation. Postoperative CT confirmed that 46 screws (95.8%) were graded as GRS Grade A. Among the S1 pedicle screws (n = 16), the median deviation from the planned trajectory was 0.5 mm (IQR 0.3–0.8) in the axial plane and 0.8 mm (IQR 0.5–0.9) in the sagittal plane. For S1AI and S2AI screws (n = 30), the median deviation at the entry point was 0.7 mm (IQR 0.3–1.2), while the median axial deviation from the medial SI joint border measured 0.9 mm (IQR 0.6–1.7). Conclusion: This first cadaveric validation of 3D MRI-guided RA sacropelvic fixation demonstrates the feasibility of radiation-free preoperative imaging and robotic registration for precise trajectory execution.

  • Open Access

    Video-enhanced informed consent improves patient comprehension in reverse total shoulder arthroplasty: a randomized controlled trial

    by Paul D. Scheidegger, Franziska C.S. Altorfer, Bettina Hochreiter, Karl Wieser, Mazda Farshad, Samy Bouaicha


  • Open Access

    Proximal Facet Joint Violations in Augmented Reality-Guided versus Freehand Pedicle Screw Placement in the Lumbosacral Spine

    by Giuseppe Loggia, Aron Alakmeh, Franziska C.S. Altorfer, Fedan Avrumova, Marco D. Burkhard, Jiaqi Zhu, Frank P. Cammisa, Andrew A. Sama, Mazda Farshad, Darren R. Lebl

  • Open Access

    Evaluating the Learning Curve and Surgical Efficacy in the Novel Robotic-Assisted Muscle-Preserving (RAMP) Spinal Decompression

    by Giuseppe Loggia, Fedan Avrumova, Marco D. Burkhard, Michael J. Kelly, Franziska C. S. Altorfer, Maksym Polt, Jiaqi Zhu, Joseph L. Chazen, Ek T. Tan, Darren R. Lebl

    Study Design: Comparative cadaveric validation. Objectives: To evaluate the influence of prior surgical experience on the accuracy and efficiency of robotic-assisted muscle-preserving (RAMP) decompression using human specimens. Methods: RAMP decompressions were performed from T8 - L5 in 8 cadavers by a non-fellowship-trained surgeon (NFTS) and a fellowship-trained surgeon (FTS). Computed tomography (CT) images were used for preoperative robotic planning and registration. Operative durations were documented, postoperative CT imaging was used to evaluate decompression accuracy and quantified anterior cortical bone removal (ACBR). Results: A total of 80 levels underwent RAMP decompression (40 thoracic, 40 lumbar). Median single-level operative times were 2.6 min (IQR 1.9-3.7) for NFTS and 2.1 min (IQR 1.6-3.0) for FTS, with no significant difference ( P = 0.109). Decompression accuracy demonstrated submillimeter deviation from planned margins, with posterior deviation measuring 0.6 mm (IQR 0.5-1.5) for NFTS and 0.7 mm (IQR 0.4-1.0) for FTS ( P = 0.573), and anterior deviation measuring 0.3 mm (IQR 0.1-0.5) in both ( P = 0.938). ACBR did not differ significantly between NFTS and FTS. Operative times declined with experience in both surgeons. Initial single-level RAMP decompressions showed greater variability (NFTS: 3.13-8.10 min; FTS: 1.39-10.56 min), while later cases converged to narrower ranges (NFTS: 1.18-2.46 min; FTS: 1.16-2.11 min). Conclusions: This first comparative cadaveric study evaluating surgeon experience in the novel RAMP decompression demonstrates high accuracy and incrementally improving efficiency regardless of prior robotic experience. These findings support the integration of decompression into robotic workflows and pave the way for a broader applicability of high-precision, muscle-preserving techniques in spine surgery.


  • Lumbar Spine Bone MRI: A Radiation-Free Approach Utilizing CT-Like Imaging for Diagnosing Pars Defects in the Adolescent Spine

    by Franziska C.S. Altorfer, Jenny J. Yan, Frederik Abel, Ellen Casey, Darryl B. Sneag, Ek T. Tan, Darren R. Lebl, J. Levi Chazen

    BACKGROUND AND PURPOSE: This is a retrospective cohort study to assess the quality of a synthetic bone MRI protocol by using the spoiled GRE (SPGRE) sequence and determine its usability in detecting pars defects in adolescent patients for orthopedic surgeons and radiologists. MATERIALS AND METHODS: This retrospective study included 30 adolescent patients with lumbar spondylolysis and low back pain. Patients underwent a clinical lumbar spine MRI at 3T that included a 3D SPGRE sequence; 5 patients also underwent a CT for comparison. An orthopedic spine surgeon and an attending radiologist analyzed inverted SGPR and CT images, assessing the presence of a lumbar pars defect and image quality using a 5-point Likert scale. The interreader agreement was calculated. RESULTS: Thirty patients were identified with pars defects seen in all patients on the SPGRE MRI. Image quality scores on a 5-point Likert scale measured an overall average of 4.53 ± 0.60, corresponding to good to perfect image quality, with a substantial interrater agreement with a Gwet AC2 of 0.79 [0.71, 0.88], without significant difference between the orthopedic surgeon and the radiologist (orthopedic surgeon’s score 4.50 ± 0.63, radiologist’s score 4.53 ± 0.57; P = .91). CONCLUSIONS: A synthetic bone MRI protocol using SPGRE is a viable, nonionizing alternative to CT for visualizing pars defects in adolescent patients, providing sufficient image quality for radiologists and orthopedic surgeons. Graphical Abstract


  • Open Access

    Semi-automated algorithm for rotational axis determination of the ulno-humeral joint

    by Sylvano Mania, Farah Selman, Franziska C.S. Altorfer, Stijn de Joode, Florian Grubhofer, Karl Wieser

  • Open Access

    Is Intraoperative Neuromonitoring with SSEPs and EMG Predictable for Postoperative Neurologic Deficit in Posterior Lumbar Fusion Surgery? A Retrospective Cohort Analysis

    by Marco D. Burkhard, Gisberto Evangelisti, Franziska C. S. Altorfer, Philip K. Paschal, Chukwuebuka C. Achebe, George Gorgy, Michael J. Kelly, William D. Zelenty, Federico P. Girardi, Darren R. Lebl, et al.

    Study Design: Retrospective, single-center cohort study. Objective: To evaluate intraoperative neuromonitoring (IONM) with free-run electromyography (EMG) and somatosensory evoked potentials (SSEPs) during primary posterior lumbar interbody fusion (PLIF) for degenerative conditions and associations with postoperative motor deficits (PMD). Methods: Patients undergoing PLIF from 2015 to 2020 were reviewed. Revision fusions, deformity corrections, and procedures in proximity to the conus were excluded. Patient characteristics, comorbidities, surgical details and intraoperative EMG and SSEP recordings were reevaluated. PMDs were defined as any decline of ≥1/5 strength grade compared to preoperative. Test accuracy and predictive value of SSEP and EMG events for PMD were calculated. Results: 401 patients (48.9% females, mean age 61 years, mean BMI 28.6) were included. One- and two-level fusions accounted for 67.8% and 27.7% of cases, respectively, most commonly involving L4/5 (67.8%) and L5/S1 (51.4%). EMG events occurred in 29.4% (n = 118) and SSEP events in 4.5% (n = 18). SSEP events were significantly associated with PMD ( P = 0.043), whereas EMG events were not ( P = 0.463). In multivariable regression, SSEP events predicted PMD with odds ratios of 3.85 for any SSEP event and OR 10.41 for persistent SSEP signal loss (both P = 0.002). Test performance of SSEP was limited (sensitivity: 13.6%; positive predictive value 16.7%). Conclusion: In posterior lumbar interbody fusion, SSEP events are associated with postoperative motor deficits, whereas EMG events are not. However, the overall test accuracy of IONM in predicting neurologic deficits remains limited. Instead of routine utilization, IONM should be tailored to the individual case.


  • Open Access

    Impact of iatrogenic alterations on adjacent segment degeneration after lumbar fusion surgery: a systematic review

    by Moritz Jokeit, Christos Tsagkaris, Franziska C. S. Altorfer, Frédéric Cornaz, Jess G. Snedeker, Mazda Farshad, Jonas Widmer

    Purpose: Adjacent segment degeneration (ASDeg) and disease (ASDis) remain significant challenges following lumbar spinal fusion surgery, with reported incidences of 36% for ASDeg and 11% for ASDis within two to seven years post-operation. However, the mechanisms leading to the development of ASDeg are still poorly understood. This comprehensive review aims to elucidate the multifactorial etiology of ASDeg by examining important iatrogenic alterations associated with spinal fusion. Methods: A systematic review following PRISMA guidelines was conducted to identify clinical studies quantifying the occurrence of ASDeg and ASDis after lumbar fusion surgery. An EMBASE and citation search up to April 2023 yielded 378 articles. Data extracted encompassed study design, fusion type, sample size, patient age, and incidence of ASDeg and ASDis. A total of 87 publications were analyzed in the context of iatrogenic alterations caused by surgical access (muscle damage, ligament damage, facet joint damage) and instrumentation (fusion angle, immobilization). Results: Ligament damage emerged as the most impactful iatrogenic factor promoting ASDeg and ASDis development. Similarly, muscle damage had a significant impact on long-term musculoskeletal health, with muscle-sparing approaches potentially reducing ASDis rates. Immobilization led to compensatory increased motion at adjacent segments; however, the causal link to degeneration remains inconclusive. Fusion angle showed low evidence for a strong impact due to inconsistent findings across studies. Facet joint violations were likely contributing factors but not primary initiators of ASDeg. Conclusion: Based on the analyzed literature, ligament and muscle damage are the most impactful iatrogenic factors contributing to ASDeg and ASDis development. Minimally invasive techniques, careful retractor placement, and ligament-preserving decompression may help mitigate these effects by reducing undue muscle and ligament trauma. Although it is not possible to definitively advocate for one or more techniques, the principle of selecting the most tissue-sparing approach needs to be scaled across surgical planning and execution. Further research is necessary to fully elucidate these mechanisms and inform surgical practices to mitigate ASDeg risk.


  • Feasibility and Accuracy of Robotic-Assisted Navigation for Thoracic Pedicle Screw Placement Using CT-Like 3D-MRI

    by Franziska C.S. Altorfer, Michael J. Kelly, Giuseppe Loggia, Fedan Avrumova, Jiaqi Ma Zhu, Gracyn Ba Campbell, J. Levi Chazen, Ek T. Tan, Darren R. Lebl

    Study Design.: Cadaveric study. Objective.: To assess the feasibility and accuracy of robotic positioning of thoracic pedicle screws based on magnetic resonance imaging (MRI). Summary of Background Data.: Robotic-assisted navigation (RAN) has demonstrated enhanced precision in thoracic pedicle screw placement. Currently, preoperative computer tomography (CT) scanning is required, exposing patients to radiation—a particular concern for younger patients undergoing multilevel fusion surgery. CT-like three-dimensional (3D)-MRI sequences may offer a radiation-free alternative, but their application in thoracic pedicle screw placement remains unexplored. Methods.: CT-like 3D-MRI scans of the thoracic spine were obtained in two human cadaveric specimens. A RAN system was employed to plan and guide 48 pedicle screws (bilateral screws in thoracic vertebrae T1-T12) using these MRI scans. Following the placement of the pedicle screws, post-procedure CT scans were obtained to evaluate the accuracy of screw positioning. Accuracy was assessed by comparing the actual placement to the pre-procedure plan (difference in millimetres) and via the Gertzbein-Robbins scale (GRS). Results.: A total of 48 thoracic pedicle screws were inserted robotically in two human specimens (T1-T12 bilaterally). Post-procedure CT scan evaluations revealed that all screws achieved an acceptable grade on the GRS (A or B). Specifically, 87.5% of the screws were classified as grade A and 12.5% were classified as grade B. The median deviations from the planned trajectory were 0.4 mm in the axial (IQR: 0.0; 1.2 mm) and 0.05 mm in the sagittal (IQR: −0.3; 0.3 mm) planes. Conclusions.: This cadaveric study demonstrates that MRI-based RAN can accurately guide thoracic pedicle screw placement. The findings suggest MRI-based RAN could provide a radiation-free alternative for thoracic spine instrumentation, particularly beneficial for pediatric and adolescent patients.