Hao Du
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hao Du has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Chenglong Fu
Southern University of Science and Technology
4 shared publications - Yuquan Leng
Harbin Institute of Technology (Shenzhen)
4 shared publications - Shucong Yin
Shenzhen Key Laboratory of Biomimetic Robotics and Intelligent Systems, Shenzhen, China
3 shared publications - Xin Lin
School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, China
3 shared publications Hongli Geng
Department of Rehabilitation Medicine, Shenzhen Second Peoples Hospital, Shenzhen, China
1 shared publicationJingfeng Xiong
Department of Mechanical and Energy Engineering, Shenzhen Key Laboratory of Biomimetic Robotics and Intelligent Systems and Guangdong Provincial Key Laboratory of Human-Augmentation and Rehabilitation Robotics in Universities, Southern University of Science and Technology, Shenzhen, China
1 shared publication
Latest Publications
- 23 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 6997-7008
Improving Energetic Efficiency and Practicality With a Suspended Backpack During Load Carriage
Suspended backpacks reduce the energetic cost of load carriage, but existing designs often focus on minimizing peak load acceleration, resulting in lower efficiency. In addition, excessive weight and bulkiness lead to compromised practicality. This study introduces a lightweight and compact suspended backpack that actively adjusts human-load interaction to achieve a near out-of-phase shift between human and load motion. Experiments were conducted under three conditions: walking with the designed backpack with a locked load (LOCK), with a human-load interaction-controlled load (AUTO), and with a traditional backpack (TRAD). In-lab experiments showed that the net metabolic cost in the AUTO condition was reduced by an average of 23.40% and 21.20% compared to the LOCK and TRAD conditions, respectively. In the AUTO condition, peak heel-strike force and peak push-off force were reduced by 13.44% and 8.54% compared to the LOCK condition, and by 14.29% and 4.08% compared to the TRAD condition. In outdoor experiments, the energy used to travel a given distance in the AUTO condition decreased by 9.01% and 8.25% compared to the LOCK and TRAD conditions, respectively. These results confirm that the designed suspended backpack enhances biomechanical efficiency in both laboratory and real-world settings.
- 23 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 6997-7008
Improving Energetic Efficiency and Practicality With a Suspended Backpack During Load Carriage
Suspended backpacks reduce the energetic cost of load carriage, but existing designs often focus on minimizing peak load acceleration, resulting in lower efficiency. In addition, excessive weight and bulkiness lead to compromised practicality. This study introduces a lightweight and compact suspended backpack that actively adjusts human-load interaction to achieve a near out-of-phase shift between human and load motion. Experiments were conducted under three conditions: walking with the designed backpack with a locked load (LOCK), with a human-load interaction-controlled load (AUTO), and with a traditional backpack (TRAD). In-lab experiments showed that the net metabolic cost in the AUTO condition was reduced by an average of 23.40% and 21.20% compared to the LOCK and TRAD conditions, respectively. In the AUTO condition, peak heel-strike force and peak push-off force were reduced by 13.44% and 8.54% compared to the LOCK condition, and by 14.29% and 4.08% compared to the TRAD condition. In outdoor experiments, the energy used to travel a given distance in the AUTO condition decreased by 9.01% and 8.25% compared to the LOCK and TRAD conditions, respectively. These results confirm that the designed suspended backpack enhances biomechanical efficiency in both laboratory and real-world settings.
- 2 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 54 (2) , 162-171
Design and Investigation of a Suspended Backpack With Wide-Range Variable Stiffness Suspension for Reducing Energetic Cost
Suspended backpacks have been acknowledged for their advantages in load carriage, leading to the development of various designs aimed at enhancing their performance. However, current suspended backpacks typically possess fixed stiffness or limited adjustability, thereby limiting their adaptability to different load carriage tasks, such as varying walking speeds and load masses. This article introduced a suspended backpack design capable of modulating its stiffness over a wide range while maintaining a lightweight profile. The variable stiffness suspension (VSS) was integrated into the load frame of the suspended backpack and utilized a motor to adjust the stiffness by generating spring-like force based on the relative displacement between the load and the body. Experimental validation was conducted to assess the stiffness modulation of the suspended backpack. The VSS enabled the stiffness modulation of the suspended backpack ranging from 424 to 2182 N/m, which corresponded to the desired stiffness range for a 10–25 kg load at walking speeds for 3.5–6 km/h. Moreover, the mechanics of the carriers were analyzed to evaluate the impact of the suspended backpack on the individuals. Results showed that the designed VSS suspended backpack could reduce peak push-off force by 20.71% under the high working condition and energetic cost by 30.39% under the midworking condition. However, a tradeoff exists between minimizing the peak accelerative load force and energetic cost. The proposed design holds the potential for enhancing performance across various load carriage tasks, including human-in-the-loop energetic optimization.
- 2 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 54 (2) , 162-171
Design and Investigation of a Suspended Backpack With Wide-Range Variable Stiffness Suspension for Reducing Energetic Cost
Suspended backpacks have been acknowledged for their advantages in load carriage, leading to the development of various designs aimed at enhancing their performance. However, current suspended backpacks typically possess fixed stiffness or limited adjustability, thereby limiting their adaptability to different load carriage tasks, such as varying walking speeds and load masses. This article introduced a suspended backpack design capable of modulating its stiffness over a wide range while maintaining a lightweight profile. The variable stiffness suspension (VSS) was integrated into the load frame of the suspended backpack and utilized a motor to adjust the stiffness by generating spring-like force based on the relative displacement between the load and the body. Experimental validation was conducted to assess the stiffness modulation of the suspended backpack. The VSS enabled the stiffness modulation of the suspended backpack ranging from 424 to 2182 N/m, which corresponded to the desired stiffness range for a 10–25 kg load at walking speeds for 3.5–6 km/h. Moreover, the mechanics of the carriers were analyzed to evaluate the impact of the suspended backpack on the individuals. Results showed that the designed VSS suspended backpack could reduce peak push-off force by 20.71% under the high working condition and energetic cost by 30.39% under the midworking condition. However, a tradeoff exists between minimizing the peak accelerative load force and energetic cost. The proposed design holds the potential for enhancing performance across various load carriage tasks, including human-in-the-loop energetic optimization.
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (6) , 2001-2011
Biomechanical Consequences of Walking With the Suspended Backpacks
Objective: This article aimed to investigate the biomechanical mechanisms underlying the energetic advantages of the suspended backpacks during load carriage. Methods: In this study, we examined eight adults walking with a 15 kg load at 5 km/h with a designed suspended backpack, in which the load could be switched to locked and suspended with four combinations of stiffness. Mechanical work and metabolic cost were measured during load carriage. Results: The results showed that the suspended backpacks led to an average reduction of 23.35% in positive work, 24.77% in negative work, and a 12.51% decrease in metabolic cost across all suspended load conditions. Notably, the decreased mechanical work predominantly occurred during single support (averaging 84.19% and 71.16% for positive and negative work, respectively), rather than during double support. Conclusion: Walking with the suspended backpack induced a phase shift between body movement and load movement, altering the human-load interaction. This adjustment caused the body and load to move against each other, resulting in flatter trajectories of the human-load system center of mass (COM) velocities and corresponding profiles in ground reaction forces (GRFs), along with reduced vertical excursions of the trunk. Consequently, this interplay led to flatter trajectories in mechanical work rate and reduced mechanical work, ultimately contributing to the observed reduction in energetic expenditure. Significance: Understanding these mechanisms is essential for the development of more effective load-carrying devices and strategies in various applications, particularly for enhancing walking abilities during load carriage.
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (6) , 2001-2011
Biomechanical Consequences of Walking With the Suspended Backpacks
Objective: This article aimed to investigate the biomechanical mechanisms underlying the energetic advantages of the suspended backpacks during load carriage. Methods: In this study, we examined eight adults walking with a 15 kg load at 5 km/h with a designed suspended backpack, in which the load could be switched to locked and suspended with four combinations of stiffness. Mechanical work and metabolic cost were measured during load carriage. Results: The results showed that the suspended backpacks led to an average reduction of 23.35% in positive work, 24.77% in negative work, and a 12.51% decrease in metabolic cost across all suspended load conditions. Notably, the decreased mechanical work predominantly occurred during single support (averaging 84.19% and 71.16% for positive and negative work, respectively), rather than during double support. Conclusion: Walking with the suspended backpack induced a phase shift between body movement and load movement, altering the human-load interaction. This adjustment caused the body and load to move against each other, resulting in flatter trajectories of the human-load system center of mass (COM) velocities and corresponding profiles in ground reaction forces (GRFs), along with reduced vertical excursions of the trunk. Consequently, this interplay led to flatter trajectories in mechanical work rate and reduced mechanical work, ultimately contributing to the observed reduction in energetic expenditure. Significance: Understanding these mechanisms is essential for the development of more effective load-carrying devices and strategies in various applications, particularly for enhancing walking abilities during load carriage.
- 3 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 235-244
Adaptive Oscillator-Based Gait Feature Extraction Method of Hip Exoskeleton for Stroke Patients
For a lower-limb exoskeleton, accurate and timely extraction of gait features, such as the timing of important gait events and walking state transitions, is a fundamental requirement to provide appropriate assistive action, and this becomes much more challenging for stroke patients due to the existence of hemiplegic gait. In view of this, this study develops an adaptive oscillator-based gait feature extraction method only using thigh-worn inertial measurement units (IMUs) for assisting stroke patients with portable hip exoskeletons. The algorithm is capable of 1) estimating the zero position of the thigh during locomotion, 2) estimating the timing of heel strike, and 3) detecting the walking state transition timely. To validate the proposed method, an experimental study with both healthy subjects and stroke patients has been performed, suggesting accurate estimations of the zero position of the thigh and the timing of heel strike, and a lower detection delay of walking state transitions compared to state-of-the-art studies. To the best of the authors’ knowledge, this study represents the first proof of feasibility to extract these gait features of stroke patients with hemiplegic gait only using thigh-worn IMUs, paving the way for future clinical applications of portable hip exoskeletons.
- 3 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (1) , 235-244
Adaptive Oscillator-Based Gait Feature Extraction Method of Hip Exoskeleton for Stroke Patients
For a lower-limb exoskeleton, accurate and timely extraction of gait features, such as the timing of important gait events and walking state transitions, is a fundamental requirement to provide appropriate assistive action, and this becomes much more challenging for stroke patients due to the existence of hemiplegic gait. In view of this, this study develops an adaptive oscillator-based gait feature extraction method only using thigh-worn inertial measurement units (IMUs) for assisting stroke patients with portable hip exoskeletons. The algorithm is capable of 1) estimating the zero position of the thigh during locomotion, 2) estimating the timing of heel strike, and 3) detecting the walking state transition timely. To validate the proposed method, an experimental study with both healthy subjects and stroke patients has been performed, suggesting accurate estimations of the zero position of the thigh and the timing of heel strike, and a lower detection delay of walking state transitions compared to state-of-the-art studies. To the best of the authors’ knowledge, this study represents the first proof of feasibility to extract these gait features of stroke patients with hemiplegic gait only using thigh-worn IMUs, paving the way for future clinical applications of portable hip exoskeletons.