Bernard Masserey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bernard Masserey has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bernadette Tobler-Ammann
Department of Plastic and Hand Surgery, Inselspital Bern, University of Bern, Bern, Switzerland
1 shared publication - Esther Vögelin
Department of Plastic and Hand Surgery, Inselspital, Bern University Hospital, Switzerland
1 shared publication Frédéric Schuind
Department of Orthopaedics and Surgery, Université Libre de Bruxelles, Brussels, Belgium
1 shared publicationLoïc Voillat
Swibrace Ltd, Fribourg, Switzerland
1 shared publicationNoé Murith
Department of Mechanical Engineering, HES-SO University of Applied Sciences, Fribourg, Switzerland
1 shared publication- Paul Fromme
Department of Mechanical Engineering, University College London, London WC1E 6BT, UK
1 shared publication
Latest Publications
- 2 February 2024
- Published by Georg Thieme Verlag KG in Journal of Wrist Surgery
- Vol. 13 (05) , 390-397
Developing 3D-Printed Wrist Splints for Distal Radius and Scaphoid Fractures
Background The purpose of this study is to optimize conservative treatment of distal radius and scaphoid fracture, in terms of comfort, fracture stabilization, and prevention of cast complications. Description of Technique Advances in additive manufacturing have allowed the development of patient-specific anatomical braces (PSABs) which have the potential to fulfill this purpose. Our specific aims were to develop a model of PSAB, adapted to fracture care, to evaluate if this brace would be well tolerated by healthy volunteers and to determine its mechanical properties as compared with conventional methods of wrist immobilization. Materials and Methods Several three-dimensional-printed splint prototypes were designed by mechanical engineers based on surgeons' and hand therapists' clinical expertise. These experimental braces underwent testing in a preclinical study involving 10 healthy volunteers, assessing comfort, satisfaction, and activities. The final prototype was mechanically compared with a conventional cast and a prefabricated splint, testing different closing systems. A mathematical algorithm was created to automatically adapt the final PSAB model to the patient's anatomy. Results The final prototype achieved an overall satisfaction score of 79%, weighing less than 90 g, made from polyamide, and fixed using hook and loop straps. The PSAB stiffness varied between 0.64 and 0.99 Nm/degree, surpassing the performance of both conventional plaster casts and prefabricated splints. Conclusion The final wrist PSAB model, adapted for fracture treatment, is lightweight, comfortable, and provides anatomical contention. It is currently being tested for the treatment of stable distal radius and scaphoid fractures in comparison to conventional plaster cast.
- 2 February 2024
- Published by Georg Thieme Verlag KG in Journal of Wrist Surgery
- Vol. 13 (05) , 390-397
Developing 3D-Printed Wrist Splints for Distal Radius and Scaphoid Fractures
Background The purpose of this study is to optimize conservative treatment of distal radius and scaphoid fracture, in terms of comfort, fracture stabilization, and prevention of cast complications. Description of Technique Advances in additive manufacturing have allowed the development of patient-specific anatomical braces (PSABs) which have the potential to fulfill this purpose. Our specific aims were to develop a model of PSAB, adapted to fracture care, to evaluate if this brace would be well tolerated by healthy volunteers and to determine its mechanical properties as compared with conventional methods of wrist immobilization. Materials and Methods Several three-dimensional-printed splint prototypes were designed by mechanical engineers based on surgeons' and hand therapists' clinical expertise. These experimental braces underwent testing in a preclinical study involving 10 healthy volunteers, assessing comfort, satisfaction, and activities. The final prototype was mechanically compared with a conventional cast and a prefabricated splint, testing different closing systems. A mathematical algorithm was created to automatically adapt the final PSAB model to the patient's anatomy. Results The final prototype achieved an overall satisfaction score of 79%, weighing less than 90 g, made from polyamide, and fixed using hook and loop straps. The PSAB stiffness varied between 0.64 and 0.99 Nm/degree, surpassing the performance of both conventional plaster casts and prefabricated splints. Conclusion The final wrist PSAB model, adapted for fracture treatment, is lightweight, comfortable, and provides anatomical contention. It is currently being tested for the treatment of stable distal radius and scaphoid fractures in comparison to conventional plaster cast.
- Open Access
- 22 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 49
Corrosion thickness loss monitoring using high-frequency guided ultrasonic waves
SPIE Digital Library Proceedings
- 22 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 49
Open AccessCorrosion thickness loss monitoring using high-frequency guided ultrasonic waves
SPIE Digital Library Proceedings