Birgit Scheppat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Birgit Scheppat has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- André Giesbrecht
IFA—Institute for Innovative Automotive Drives, Kempten University of Applied Sciences, Bahnhofstraße 61, 87435 Kempten, Germany
1 shared publication - Christoph Zettler
IFA—Institute for Innovative Automotive Drives, Kempten University of Applied Sciences, Bahnhofstraße 61, 87435 Kempten, Germany
1 shared publication - Georg Derscheid
Laboratory for Hydrogen Technologies and Energy Storage, RheinMain University of Applied Sciences, Am Brueckweg 26, 65428 Ruesselsheim, Germany
1 shared publication - Ludwig K. Robl
IFA—Institute for Innovative Automotive Drives, Kempten University of Applied Sciences, Bahnhofstraße 61, 87435 Kempten, Germany
1 shared publication - Maximilian Kleber
Laboratory for Hydrogen Technologies and Energy Storage, RheinMain University of Applied Sciences, Am Brueckweg 26, 65428 Ruesselsheim, Germany
1 shared publication - Moritz Gegenbauer
IFA—Institute for Innovative Automotive Drives, Kempten University of Applied Sciences, Bahnhofstraße 61, 87435 Kempten, Germany
1 shared publication
Latest Publications
- Open Access
Design and Experimental Validation of a Fuel Cell Powertrain Test Bench for Energy Management Strategy Evaluation
The development of fuel cell electric vehicles (FCEVs) remains challenged by complex system integration, powertrain design, and the limited availability of experimental data under realistic operating conditions, which constrains the validation of energy management systems (EMSs) and system-level performance assessment. To address this gap, this study presents a validated test bench platform for fuel cell powertrains that combines a hardware-based powertrain test bench with a simulation environment for EMS analysis. The platform enables the integration and testing of a fuel cell powertrain in an electric van under realistic operating conditions. Validation under the US06 driving cycle shows an equivalent hydrogen consumption deviation of only 5.1 g (2.4%) between the hardware and simulation environments, demonstrating high platform reliability. A comparative analysis of load-following and average load power strategies is conducted. Results indicate that the average load power strategy achieves higher energy efficiency, reducing equivalent hydrogen consumption by 1.8%, 3.8%, and 6.4% under city, rural, and highway conditions, respectively. The efficiency advantage becomes increasingly pronounced as power demand rises. The proposed platform provides a validated framework for system-level development, validation, and evaluation of fuel cell powertrain systems.
Open AccessDesign and Experimental Validation of a Fuel Cell Powertrain Test Bench for Energy Management Strategy Evaluation
The development of fuel cell electric vehicles (FCEVs) remains challenged by complex system integration, powertrain design, and the limited availability of experimental data under realistic operating conditions, which constrains the validation of energy management systems (EMSs) and system-level performance assessment. To address this gap, this study presents a validated test bench platform for fuel cell powertrains that combines a hardware-based powertrain test bench with a simulation environment for EMS analysis. The platform enables the integration and testing of a fuel cell powertrain in an electric van under realistic operating conditions. Validation under the US06 driving cycle shows an equivalent hydrogen consumption deviation of only 5.1 g (2.4%) between the hardware and simulation environments, demonstrating high platform reliability. A comparative analysis of load-following and average load power strategies is conducted. Results indicate that the average load power strategy achieves higher energy efficiency, reducing equivalent hydrogen consumption by 1.8%, 3.8%, and 6.4% under city, rural, and highway conditions, respectively. The efficiency advantage becomes increasingly pronounced as power demand rises. The proposed platform provides a validated framework for system-level development, validation, and evaluation of fuel cell powertrain systems.
- Open Access
- 3 February 2024
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 15 (2) , 49
Systematic Evaluation of Possible Maximum Loads Caused by Electric Vehicle Charging and Heat Pumps and Their Effects on Common Structures of German Low-Voltage Grids
In this paper, we present a comprehensive assessment of the effects of residential loads, electric vehicles (EVs), and electric heat pumps (HPs) on low-voltage (LV) grids in urban, suburban, and rural areas of Germany. Firstly, real data are used to determine the typical structures for each LV grid region. Secondly, nine scenarios are defined with different levels of EV and HP penetration. Thirdly, the Low Voltage Load Flow Calculation in the DIgSILENT PowerFactory is performed for all scenarios while taking the simultaneity factor (SF) for each load type into consideration to calculate the minimum voltage and maximum loadings of transformer and lines in each grid; this allows for the grid’s potential bottlenecks to be identified. The network simulations are carried out with the consideration of charging powers of 11 kW and 22 kW in order to evaluate how an increasing EV load in the future may affect the grid’s parameters. To the best of our knowledge, no study in the literature has simultaneously addressed all of the aforementioned topics. The results of this study provide a useful framework that distribution system operators (DSOs) may apply to anticipate the forthcoming challenges and figure out when grid reinforcement will be required.
- 3 February 2024
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 15 (2) , 49
Open AccessSystematic Evaluation of Possible Maximum Loads Caused by Electric Vehicle Charging and Heat Pumps and Their Effects on Common Structures of German Low-Voltage Grids
In this paper, we present a comprehensive assessment of the effects of residential loads, electric vehicles (EVs), and electric heat pumps (HPs) on low-voltage (LV) grids in urban, suburban, and rural areas of Germany. Firstly, real data are used to determine the typical structures for each LV grid region. Secondly, nine scenarios are defined with different levels of EV and HP penetration. Thirdly, the Low Voltage Load Flow Calculation in the DIgSILENT PowerFactory is performed for all scenarios while taking the simultaneity factor (SF) for each load type into consideration to calculate the minimum voltage and maximum loadings of transformer and lines in each grid; this allows for the grid’s potential bottlenecks to be identified. The network simulations are carried out with the consideration of charging powers of 11 kW and 22 kW in order to evaluate how an increasing EV load in the future may affect the grid’s parameters. To the best of our knowledge, no study in the literature has simultaneously addressed all of the aforementioned topics. The results of this study provide a useful framework that distribution system operators (DSOs) may apply to anticipate the forthcoming challenges and figure out when grid reinforcement will be required.