JMJan Müller

Jan Müller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jan Müller has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Tracking individual action potentials throughout mammalian axonal arbors

    by Milos Radivojevic, Felix Franke, Michael Altermatt, Jan Müller, Andreas Hierlemann, Douglas J Bakkum

    Axons are neuronal processes specialized for conduction of action potentials (APs). The timing and temporal precision of APs when they reach each of the synapses are fundamentally important for information processing in the brain. Due to small diameters of axons, direct recording of single AP transmission is challenging. Consequently, most knowledge about axonal conductance derives from modeling studies or indirect measurements. We demonstrate a method to noninvasively and directly record individual APs propagating along millimeter-length axonal arbors in cortical cultures with hundreds of microelectrodes at microsecond temporal resolution. We find that cortical axons conduct single APs with high temporal precision (~100 µs arrival time jitter per mm length) and reliability: in more than 8,000,000 recorded APs, we did not observe any conduction or branch-point failures. Upon high-frequency stimulation at 100 Hz, successive became slower, and their arrival time precision decreased by 20% and 12% for the 100th AP, respectively.


  • 2048 action potential recording channels with 2.4 μVrms noise and stimulation artifact suppression

    by Vijay Viswam, Yihui Chen, Amir Shadmani, Jelena Dragas, Raziyeh Bounik, Radivojevic Milos, Jan Muller, Andreas Hierlemann

    Here, we present 2048 low-noise, low-offset, and low-power action-potential recording channels, integrated in a multi-functional high-density microelectrode array. A resistively loaded open-loop topology has been adapted for the first-stage amplifier to achieve 2.4 μVrms noise levels at low power consumption. Two novel pseudo-resistor structures have been used to realize very low HPF corner frequencies with small variations across all channels. The adjustability of pseudo resistors has been exploited to realize a "soft" reset technique that suppresses stimulation artifacts so that the amplifiers can recover from saturation within 200 μs. The chips were fabricated in a 0.18 μm 6M1P CMOS process, and measurement results are presented to show the performance of the proposed circuit structures and techniques.


  • Open Access

    Optimizing Spike-Sorting Yield through Selection of Optimal Recording Sites in High-density Microelectrode Arrays

    by Jan Müller, Felix Franke, Michele Fiscella, Urs Frey, Douglas Bakkum, Andreas Hierlemann

    Motivation Recently, various high-density microelectrode arrays (HDMEA) were developed for in-vitro and in-vivo applications. Some of these arrays feature hundreds to thousands of electrodes, from which a subset can be selected for recording at one time [1-4]. Our goal here is to simultaneously extract the activity of a maximum number of identifiable neurons from such recordings. Careful choice of recording electrodes is required, when the number of recorded neurons exceeds the number of available recording channels. When analyzing data from networks of neurons, one is typically interested in the exact relative timing of the occurrence of action potentials in different neurons. Here, we consider the assignment of recorded action potentials to individual neurons a classification problem. Therefore, we propose a metric relying on linear discriminant analysis (LDA) to compute the expected classification error for a given electrode arrangement. Moreover, we propose an algorithm to automatically find optimal electrode configurations. Material and Methods HDMEA: To demonstrate the feasibility of our method, we used a recently developed HDMEA featuring 26,400 Pt microelectrodes, arranged in a grid-like configuration with a center-to-center pitch of 17.5 μm [3]. 1024 of these electrodes can be selected for simultaneous recording by means of low-noise amplifiers (2.4 μV rms in the action potential signal band 300 Hz–10 kHz). Algorithm: The extent to which action potentials from two neurons can be clearly distinguished depends on their multi-electrode waveforms. The best separation can be achieved if information from all electrodes is available. However, only a subset of all available electrodes can be used for recording at the same time. Our method starts out by successively recording through blocks of all 26,400 electrodes, spike sorting each of the recordings, and building templates for each neuron (Step 1). Using the templates from all neurons and linear discriminant analysis [5], we compute the expected spike sorting error (ESSE) using all electrodes. We then compute for each electrode the ESSE under the assumption that the corresponding electrode would not be used for recording (Step 2). Electrodes, the removal of which increases the ESSE by the least amount will then be discarded (Step 3). Step 2 and 3 are iterated until the desired number of electrodes, i.e., the number of available readout channels is reached. Results We recorded from a patch of hamster retina for ten minutes per electrode. Based on this data, action potential templates were computed, and the algorithm has been applied to identify the optimal recording electrodes. The classification error decays exponentially upon increasing the number of used electrodes. Discussion/Conclusion We have presented a framework to assess the quality of a particular recording scenario. The framework quantifies the error probability for discriminating between all a-priori known templates for all present neurons. The algorithm was applied to recordings from a retina performed with a recently developed HDMEA. Our approach is related to earlier work [6]. However, by relying on linear discriminant analysis, we make - in a Bayesian sense - optimal use of the available recording resources. [1] Lopez, Carolina M., et al. "A 966-electrode neural probe with 384 configurable channels in 0.13μm SOI CMOS", ISSCC (2016), 392-393. [2] Viswam, Vijay, et al. "Multi-Functional Microelectrode Array System featuring 59’760 Electrodes, 2048 Electrophysiology Channels, Impedance and Neurotransmitter Measurement Units", ISSCC (2016), 394-396. [3] Ballini, Marco, et al. "A 1024-Channel CMOS microelectrode array with 26,400 electrodes for recording and stimulation of electrogenic cells in vitro." Solid-State Circuits, IEEE Journal of 49.11 (2014): 2705-2719. [4] Seidl, Karsten, et al. "CMOS-based high-density silicon microprobe arrays for electronic depth control in intracortical neural recording" Microelectromechanical Systems, Journal of, 20(6):1439– 1448, 2011. [5] Franke, Felix, et al. "Bayes Optimal Template Matching for Spike Sorting – Combining Fisher Discriminant Analysis with Optimal Filtering, " J. Comput. Neurosci., vol. 38, no. 3, pp. 439–459, 2015. [6] Vysotska, Olga, "Automatic channel selection and neural signal estimation across channels of neural probes", International Conference on Intelligent Robots and Systems (2014), 1453–1459.

  • Top Cited Papers
    Open Access

    High-resolution CMOS MEA platform to study neurons at subcellular, cellular, and network levels

    by Jan Müller, Marco Ballini, Paolo Livi, Yihui Chen, Milos Radivojevic, Amir Shadmani, Vijay Viswam, Ian L. Jones, Michele Fiscella, Roland Diggelmann, et al.

    Studies on information processing and learning properties of neuronal networks would benefit from simultaneous and parallel access to the activity of a large fraction of all neurons in such networks. Here, we present a CMOS-based device, capable of simultaneously recording the electrical activity of over a thousand cells in in vitro neuronal networks. The device provides sufficiently high spatiotemporal resolution to enable, at the same time, access to neuronal preparations on subcellular, cellular, and network level. The key feature is a rapidly reconfigurable array of 26 400 microelectrodes arranged at low pitch (17.5 μm) within a large overall sensing area (3.85 × 2.10 mm2). An arbitrary subset of the electrodes can be simultaneously connected to 1024 low-noise readout channels as well as 32 stimulation units. Each electrode or electrode subset can be used to electrically stimulate or record the signals of virtually any neuron on the array. We demonstrate the applicability and potential of this device for various different experimental paradigms: large-scale recordings from whole networks of neurons as well as investigations of axonal properties of individual neurons.


  • Open Access

    High-density microelectrode array recordings and real-time spike sorting for closed-loop experiments: an emerging technology to study neural plasticity

    by Felix Franke, David Jäckel, Jelena Dragas, Jan Müller, Milos Radivojevic, Douglas Bakkum, Andreas Hierlemann

    Understanding plasticity of neural networks is a key to comprehending their development and function. A powerful technique to study neural plasticity includes recording and control of pre- and post-synaptic neural activity, e.g., by using simultaneous intracellular recording and stimulation of several neurons. Intracellular recording is, however, a demanding technique and has its limitations in that only a small number of neurons can be stimulated and recorded from at the same time. Extracellular techniques offer the possibility to simultaneously record from larger numbers of neurons with relative ease, at the expenses of increased efforts to sort out single neuronal activities from the recorded mixture, which is a time consuming and error prone step, referred to as spike sorting. In this mini-review, we describe recent technological developments in two separate fields, namely CMOS-based high-density microelectrode arrays, which also allow for extracellular stimulation of neurons, and real-time spike sorting. We argue that these techniques, when combined, will provide a powerful tool to study plasticity in neural networks consisting of several thousand neurons in vitro.