Xiaofeng Zhang
Xiaofeng Zhang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Haiying Wang
Key Laboratory of Road Construction Technology and Equipment of MOE, Chang’an University, Xi’an, China
4 shared publications - Long Chen
Key Laboratory of Road Construction Technology and Equipment of Ministry of Education, Chang’an University, Xi’an 710064, China
2 shared publications - Yingzhi Zhang
Shaanxi Transportation Holding Group Co., Ltd., Xi'an 710075, China
2 shared publications - Yuke Shi
Key Laboratory of Road Construction Technology and Equipment of Ministry of Education, Chang’an University, Xi’an 710064, China
2 shared publications - Jian Xu
School of Management, Xi’an University of Science and Technology, Xi’an 710054, China
1 shared publication - Keyu Zhao
School of Construction Machinery, Chang’an University, Xi’an 710064, China
1 shared publication
Latest Publications
- Open Access
A Tunnel Fire Detection Method Based on an Improved Dempster-Shafer Evidence Theory
Tunnel fires are generally detected using various sensors, including measuring temperature, CO concentration, and smoke concentration. To address the ambiguity and inconsistency in multi-sensor data, this paper proposes a tunnel fire detection method based on an improved Dempster-Shafer (DS) evidence theory for multi-sensor data fusion. To solve the problem of evidence conflict in the DS theory, a two-level multi-sensor data fusion framework is adopted. The first level of fusion involves feature fusion of the same type of sensor data, removing ambiguous data to obtain characteristic data, and calculating the basic probability assignment (BPA) function through the feature interval. The second-level fusion derives basic probability numbers from the BPA, calculates the degree of evidence conflict, normalizes the BPA to obtain the relative conflict degree, and optimizes the BPA using the trust coefficient. The classical DS evidence theory is then used to integrate and obtain the probability of tunnel fire occurrence. Different heat release rates, tunnel wind speeds, and fire locations are set, forming six fire scenarios. Sensor monitoring data under each simulation condition are extracted and fused using the improved DS evidence theory. The results show that there is a 67.5%, 83.5%, 76.8%, 83%, 79.6%, and 84.1% probability of detecting fire when it occurs, respectively, and identifies fire occurrence in approximately 2.4 s, an improvement from 64.7% to 70% over traditional methods. This demonstrates the feasibility and superiority of the proposed method, highlighting its significant importance in ensuring personnel safety.
Open AccessA Tunnel Fire Detection Method Based on an Improved Dempster-Shafer Evidence Theory
Tunnel fires are generally detected using various sensors, including measuring temperature, CO concentration, and smoke concentration. To address the ambiguity and inconsistency in multi-sensor data, this paper proposes a tunnel fire detection method based on an improved Dempster-Shafer (DS) evidence theory for multi-sensor data fusion. To solve the problem of evidence conflict in the DS theory, a two-level multi-sensor data fusion framework is adopted. The first level of fusion involves feature fusion of the same type of sensor data, removing ambiguous data to obtain characteristic data, and calculating the basic probability assignment (BPA) function through the feature interval. The second-level fusion derives basic probability numbers from the BPA, calculates the degree of evidence conflict, normalizes the BPA to obtain the relative conflict degree, and optimizes the BPA using the trust coefficient. The classical DS evidence theory is then used to integrate and obtain the probability of tunnel fire occurrence. Different heat release rates, tunnel wind speeds, and fire locations are set, forming six fire scenarios. Sensor monitoring data under each simulation condition are extracted and fused using the improved DS evidence theory. The results show that there is a 67.5%, 83.5%, 76.8%, 83%, 79.6%, and 84.1% probability of detecting fire when it occurs, respectively, and identifies fire occurrence in approximately 2.4 s, an improvement from 64.7% to 70% over traditional methods. This demonstrates the feasibility and superiority of the proposed method, highlighting its significant importance in ensuring personnel safety.
- Open Access
- 8 August 2024
- Published by MDPI AG in Preprints.org
Tunnel Fire Detection Method Based on Improved DS Evidence Theory
Tunnel fires are generally detected using various sensors, including measuring temperature, CO concentration, and smoke concentration. To address the ambiguity and inconsistency in multi-sensor data, this paper proposes a tunnel fire detection method based on an improved Dempster-Shafer (DS) evidence theory for multi-sensor data fusion. To solve the problem of evidence conflict in DS theory, a two-level multi-sensor data fusion framework is adopted. The first level of fusion involves feature fusion of the same type of sensor data, removing ambiguous data to obtain characteristic data, and calculating the basic probability assignment (BPA) function through the feature interval. The second level fusion derives basic probability numbers from the BPA, calculates the degree of evidence conflict, normalizes to obtain the relative conflict degree, and optimizes the BPA using the trust coefficient. The classical DS evidence theory is then used to integrate and obtain the probability of tunnel fire occurrence. Different heat release rates, tunnel wind speeds, and fire locations are set, forming four fire scenarios. Sensor monitoring data under each simulation condition are extracted and fused using the improved DS evidence theory. The results show that the proposed improved DS evidence theory method detects the probability of fire occurrence in the four scenarios as 67.5%, 71.0%, 82.8%, and 83.5%, respectively, and identifies fire occurrence in approximately 2.4 seconds, an improvement of 64.7% to 70% over traditional methods. This demonstrates the feasibility and superiority of the proposed method, highlighting its significant importance in ensuring personnel safety.
- 8 August 2024
- Published by MDPI AG in Preprints.org
Open AccessTunnel Fire Detection Method Based on Improved DS Evidence Theory
Tunnel fires are generally detected using various sensors, including measuring temperature, CO concentration, and smoke concentration. To address the ambiguity and inconsistency in multi-sensor data, this paper proposes a tunnel fire detection method based on an improved Dempster-Shafer (DS) evidence theory for multi-sensor data fusion. To solve the problem of evidence conflict in DS theory, a two-level multi-sensor data fusion framework is adopted. The first level of fusion involves feature fusion of the same type of sensor data, removing ambiguous data to obtain characteristic data, and calculating the basic probability assignment (BPA) function through the feature interval. The second level fusion derives basic probability numbers from the BPA, calculates the degree of evidence conflict, normalizes to obtain the relative conflict degree, and optimizes the BPA using the trust coefficient. The classical DS evidence theory is then used to integrate and obtain the probability of tunnel fire occurrence. Different heat release rates, tunnel wind speeds, and fire locations are set, forming four fire scenarios. Sensor monitoring data under each simulation condition are extracted and fused using the improved DS evidence theory. The results show that the proposed improved DS evidence theory method detects the probability of fire occurrence in the four scenarios as 67.5%, 71.0%, 82.8%, and 83.5%, respectively, and identifies fire occurrence in approximately 2.4 seconds, an improvement of 64.7% to 70% over traditional methods. This demonstrates the feasibility and superiority of the proposed method, highlighting its significant importance in ensuring personnel safety.
- Open Access
- 12 December 2022
- Published by Hindawi Limited in Wireless Communications and Mobile Computing
- Vol. 2022, 1-10
Prediction of Compressive Strength of Concrete Using the Spearman and PCA-Based BP Neural Network
Using real-time production data of concrete to predict its 28-day compressive strength has great significance for improving the engineering structure quality and overcoming the shortage of the traditional tests long period of concrete compressive strength. The current research has the shortcomings such as insufficient prediction accuracy, inadequate matching between data characteristics and model characteristics, and redundant input parameter information. This paper proposes a BP neural network prediction model optimized by Spearman and PCA. The model first uses Spearman method to reduce the number of the input variables by eliminating variables that have a low correlation with the compressive strength and then uses PCA to eliminate the correlation between material-related variables. Following this, the new uncorrelated input variables optimized by Spearman and PCA are input to the BP neural network-based model to predict the compressive strength of concrete. The results showed that it yielded the mean absolute percentage error (MAPE) of 2.78 and the root mean-squared error (RMSE) of 1.66MPa, far lower than the error of 4.82 and 2.92MPa obtained by the nonoptimized BP neural network, respectively. The proposed model fully exploits real-time monitoring data from the concrete mixing station, and its results are close to those of traditional tests. It has great practical significance to guide the concrete production and construction, shorten the production cycle, and reduce the project cost.
- 12 December 2022
- Published by Hindawi Limited in Wireless Communications and Mobile Computing
- Vol. 2022, 1-10
Open AccessPrediction of Compressive Strength of Concrete Using the Spearman and PCA-Based BP Neural Network
Using real-time production data of concrete to predict its 28-day compressive strength has great significance for improving the engineering structure quality and overcoming the shortage of the traditional tests long period of concrete compressive strength. The current research has the shortcomings such as insufficient prediction accuracy, inadequate matching between data characteristics and model characteristics, and redundant input parameter information. This paper proposes a BP neural network prediction model optimized by Spearman and PCA. The model first uses Spearman method to reduce the number of the input variables by eliminating variables that have a low correlation with the compressive strength and then uses PCA to eliminate the correlation between material-related variables. Following this, the new uncorrelated input variables optimized by Spearman and PCA are input to the BP neural network-based model to predict the compressive strength of concrete. The results showed that it yielded the mean absolute percentage error (MAPE) of 2.78 and the root mean-squared error (RMSE) of 1.66MPa, far lower than the error of 4.82 and 2.92MPa obtained by the nonoptimized BP neural network, respectively. The proposed model fully exploits real-time monitoring data from the concrete mixing station, and its results are close to those of traditional tests. It has great practical significance to guide the concrete production and construction, shorten the production cycle, and reduce the project cost.