YZYichi Zhang

Yichi Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yichi Zhang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Xiujian Chou

    State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China

    4 shared publications
  • Langlang Yang

    North University of China , Shanxi

    3 shared publications
  • Chenxi Ding

    Shanxi Key Laboratory of Ferroelectric Physical Micro-Nano Devices and Systems, North University of China, Taiyuan, Shanxi, China

    2 shared publications
  • Rui Feng

    Shanxi Key Laboratory of Ferroelectric Physical Micro-Nano Devices and Systems, North University of China, Taiyuan, Shanxi, China

    2 shared publications
  • Shaoyu Yan

    Shanxi Key Laboratory of Ferroelectric Physical Micro-Nano Devices and Systems, North University of China, Taiyuan, Shanxi, China

    2 shared publications
  • Wenping Geng

    Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030051, China

    2 shared publications

Latest Publications

  • Adaptive Integrated Microfluidic System with Real-Time Dielectric Feedback for Deterministic Micro-Manipulation

    by Yichi Zhang, Zihe Guo, Langlang Yang, Zihao Li, Zhimeng Zhang, Wenping Geng, Zhangbin Ji, Ruiying Wang, Jian He, Xiujian Chou

    Conventional microfluidic particle sorting systems predominantly rely on static, open-loop operational principles, rendering them highly vulnerable to performance deterioration induced by cellular phenotypic heterogeneity and localized hydrodynamic fluctuations. Here, we introduce an adaptive integrated microfluidic system (AIMS) that implements a closed-loop sensing−decision−actuation−verification control framework via on-chip integration of dual-frequency impedance cytometry (IFC) and tunable traveling surface acoustic waves (T-TSAW). An upstream IFC array (1#IFC) performs real-time, label-free electrical interrogation of single-cell dielectric phenotypes. These transient signals are processed in real time by a custom finite-state machine (FSM) algorithm to dynamically modulate the downstream T-TSAW field. Concurrently, a downstream IFC array (2#IFC) performs post-sorting verification and feeds real-time state metrics back to the FSM core. This initiates an adaptive hill-climbing optimization loop to enable continuous acoustic frequency calibration. The system performance was rigorously evaluated using monodisperse polystyrene microspheres and biologically relevant colloidal models. The closed-loop architecture successfully isolated target MCF-7 cells from an erythrocyte-dominated simplified blood model, achieving an acoustic sorting efficiency of 95 ± 1.5% and a purity of 94 ± 2.5%. Furthermore, continuous adaptive sorting of primary mouse immune cell populations (PBMCs and neutrophils) was demonstrated, achieving a sorting efficiency of 92 ± 1.8% and a purity of 93 ± 6.7%. Ultimately, the seamless integration of transient electronic sensing algorithms with multiphysics mechanical actuation establishes a highly robust architectural framework for autonomous microelectromechanical manipulation platforms.

  • Ultra-Thin Broadband Optical Skin Based on Graphene-Stack Electrochemical Structure via Ion Intercalation Tuning

    by Xing Cao, Kaixi Bi, Longhao Liu, Guangchen Yin, Jinxian Dong, Lei Hu, Yichi Zhang, Linyu Mei, Xiujian Chou

    Smart optical skins play a critical role in camouflage and intelligent thermal management. Nevertheless, realizing broadband optical modulation within ultra-thin display architectures continue to pose a substantial technical challenge. Graphene’s zero-bandgap structure facilitates broadband optical absorption modulation through the continuous modulation of its Fermi level. Among various methods, electrochemical intercalation stands out for its low power consumption and robust cycling stability based on an ultra-thin film architecture. This study introduces an innovative optical display panel based on the lithium-ion electrochemical intercalation method. Experimental results demonstrate that dynamic modulation of the Fermi level achieves a reflectance modulation of 43.07% across the visible spectrum and a transmittance modulation of 35.75% within the long-wave infrared region. A 64-pixel array device—fabricated using a fully flexible material system—achieves a total integration thickness of only 225 μm. The device exhibits a rapid spectral switching time of 491 ms, while maintaining pixel dimensions below 3 mm × 3 mm. Moreover, the modulated graphene sustains a temperature differential of 17.2 °C with respect to the background temperature of the heat source. This study establishes both a robust physical foundation and a scalable technical framework to advance the development of multispectral surfaces and next-generation wearable electronics.

  • A Novel Surface Acoustic Waveguide With Spurious Suppression for High-Quality Signal Transmission

    by Yichi Zhang, Shaoyu Yan, Langlang Yang, Chenxi Ding, Rui Feng, Wenping Geng, Jian He, Linyu Mei, Rongliang Zhang, Xiujian Chou

    This work demonstrates a low-transmission-loss acoustic waveguide explicitly tailored for microwave communication, which not only facilitates highly efficient acoustic signal transmission but also resolves crosstalk between adjacent devices. By filling the grooves of an etched lithium niobate (LiNbO3) substrate with gold, a filling slot structured (FSS) waveguide has been obtained. A simulation model was established to predict that this structure would induce an interference effect through the reflected waves at the Au–LiNbO3 heterointerface, thereby modifying the distribution of acoustic wave energy. Through experimental validation, it was demonstrated that this structure can efficiently guide the Rayleigh mode while effectively suppressing the spurious mode. The transmission loss of the acoustic wave was approximately −0.61 dB/mm, and the fluctuation range of the out-of-band response remained below 22.82 dB. In addition, we successfully demonstrated 90°- and 180°-bend waveguides based on this structure and applied them to a two-port power splitter. This indicates that the proposed structure not only enables low-loss signal transmission but also effectively suppresses spurious signals, thereby offering a novel approach for the design of high-performance acoustic waveguides.

  • Enhanced propagation of free films with fast spread-out phenomena under the influence of megahertz surface acoustic waves

    by Yichi Zhang, Rui Feng, Chenxi Ding, Shaoyu Yan, Langlang Yang, Guoxin Chang, Xiaojun Qiao, Wenping Geng, Xiujian Chou

    In this study, a novel approach for enhancing the rapid spreading of free liquid film on lithium niobate (LiNbO3) substrate under megahertz (MHz) surface acoustic wave (SAW) excitation is presented by treating it with surfactants. Through the design of a specific interdigital transducer structure, it was discovered that exciting the SAW at a frequency of 32.3 MHz can achieve optimal spreading performance for water droplets on the surface of surfactant-treated LiNbO3 substrate. The maximum average velocity reaches 1.76 mm/s at position P2 = 1250 μm in the water film front, and the stable film spreading speed shows a 204.9% increase compared to the existing research. Simultaneously, through the investigation of the spreading experiment phenomenon of silicone oil and de-ionized water droplets at varying frequencies, we have discovered the dynamic mechanism of “reverse phase” propagation in liquid film for the first time. This entails that the advancing edge of the wetting film demonstrates a spreading motion law that is opposite to the traditional spreading phenomena, with the spreading velocity in the central exceeding that on both sides. Our research demonstrates that this microfluidic device developed by SAWs enhances the spreading efficiency of the free films, enabling rapid expansion of the target liquid to form a high-surface area film layer. This advancement holds promise for overcoming the limitations of low sensitivity and short response time in the field of rapid pathological diagnosis in contemporary medicine.