Xing Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xing Liu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Xingjun Wang
Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
2 shared publications - Yifan Liu
Department of Electrical Engineering & Information Technology, Shandong University of Science and Technology, Jinan 250031, China
2 shared publications - Haoyu Xie
College of Arts and Sciences, The University of North Carolina at Chapel Hill, Chapel Hill, NC 27514, USA
1 shared publication - Jun Liu
State key Laboratory of Extreme Environment Optoelectronic Dynamic Testing Technology and Instrument, Shanxi Province Key Laboratory of Quantum Sensing and Precision Measurement, North University of China, Taiyuan, China
1 shared publication - Qianhui Zhu
Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
1 shared publication - Silin Cui
School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an 710072, China
1 shared publication
Latest Publications
- Open Access
- 8 August 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (8) , 806
Adaptive Detection in Real-Time Gait Analysis through the Dynamic Gait Event Identifier
The Dynamic Gait Event Identifier (DGEI) introduces a pioneering approach for real-time gait event detection that seamlessly aligns with the needs of embedded system design and optimization. DGEI creates a new standard for gait analysis by combining software and hardware co-design with real-time data analysis, using a combination of first-order difference functions and sliding window techniques. The method is specifically designed to accurately separate and analyze key gait events such as heel strike (HS), toe-off (TO), walking start (WS), and walking pause (WP) from a continuous stream of inertial measurement unit (IMU) signals. The core innovation of DGEI is the application of its dynamic feature extraction strategies, including first-order differential integration with positive/negative windows, weighted sleep time analysis, and adaptive thresholding, which together improve its accuracy in gait segmentation. The experimental results show that the accuracy rate of HS event detection is 97.82%, and the accuracy rate of TO event detection is 99.03%, which is suitable for embedded systems. Validation on a comprehensive dataset of 1550 gait instances shows that DGEI achieves near-perfect alignment with human annotations, with a difference of less than one frame in pulse onset times in 99.2% of the cases.
- 8 August 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (8) , 806
Open AccessAdaptive Detection in Real-Time Gait Analysis through the Dynamic Gait Event Identifier
The Dynamic Gait Event Identifier (DGEI) introduces a pioneering approach for real-time gait event detection that seamlessly aligns with the needs of embedded system design and optimization. DGEI creates a new standard for gait analysis by combining software and hardware co-design with real-time data analysis, using a combination of first-order difference functions and sliding window techniques. The method is specifically designed to accurately separate and analyze key gait events such as heel strike (HS), toe-off (TO), walking start (WS), and walking pause (WP) from a continuous stream of inertial measurement unit (IMU) signals. The core innovation of DGEI is the application of its dynamic feature extraction strategies, including first-order differential integration with positive/negative windows, weighted sleep time analysis, and adaptive thresholding, which together improve its accuracy in gait segmentation. The experimental results show that the accuracy rate of HS event detection is 97.82%, and the accuracy rate of TO event detection is 99.03%, which is suitable for embedded systems. Validation on a comprehensive dataset of 1550 gait instances shows that DGEI achieves near-perfect alignment with human annotations, with a difference of less than one frame in pulse onset times in 99.2% of the cases.
- Open Access
- 17 September 2023
- Published by Association for Computing Machinery (ACM)
- p. 46-47
Efficient Gait Trajectory Prediction Method Based on Soft Constraint Weighted Template Matching: Work-in-Progress
Embedded systems in exoskeletons and wearable rehabilitation devices require efficient monitoring of human gait with stringent demands for real-time and reliable performance. Gait trajectory prediction enables full-process perception of future gait patterns. The template matching approach is a promising algorithm for gait trajectory prediction. However, it has challenges in terms of template selection and dynamic stability. We developed DTW-KM Template Selection Method using the DTW distance matrix and K-means to find trajectories with generality and diversity as candidate templates. In addition, we use a matching method combining soft constraints and quadratic weighting, named ScW Template Matching Method. it can balance timeliness, stability and flexibility, and suppress gait phase and trajectory oscillations. Preliminary experimental results show that our method achieves stable prediction of 0.5--1s gait using efficient inference on embedded devices.
- 17 September 2023
- Published by Association for Computing Machinery (ACM)
- p. 46-47
Open AccessEfficient Gait Trajectory Prediction Method Based on Soft Constraint Weighted Template Matching: Work-in-Progress
Embedded systems in exoskeletons and wearable rehabilitation devices require efficient monitoring of human gait with stringent demands for real-time and reliable performance. Gait trajectory prediction enables full-process perception of future gait patterns. The template matching approach is a promising algorithm for gait trajectory prediction. However, it has challenges in terms of template selection and dynamic stability. We developed DTW-KM Template Selection Method using the DTW distance matrix and K-means to find trajectories with generality and diversity as candidate templates. In addition, we use a matching method combining soft constraints and quadratic weighting, named ScW Template Matching Method. it can balance timeliness, stability and flexibility, and suppress gait phase and trajectory oscillations. Preliminary experimental results show that our method achieves stable prediction of 0.5--1s gait using efficient inference on embedded devices.
- 25 April 2022
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 51 (7) , 3745-3757
Characteristics of Miniaturized Monolithic PMNT/PZT Sandwiched Transducers
- 25 April 2022
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 51 (7) , 3745-3757
Characteristics of Miniaturized Monolithic PMNT/PZT Sandwiched Transducers