Aiany Maria Queiroz Felix
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aiany Maria Queiroz Felix has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Cesar Augusto Souza Andrade
Programa de Pós-Graduação em Inovação Terapêutica, Universidade Federal de Pernambuco, Recife 50670-901, PE, Brazil
2 shared publications - Maria Danielly Lima Oliveira
Programa de Pós-Graduação em Inovação Terapêutica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil; Laboratório de Biodispositivos Nanoestruturados, Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil
2 shared publications - Severino Alves Júnior
Universidade Federal de Pernambuco
2 shared publications - Alberto Galdino DA Silva Junior
Programa de Pós-Graduação em Inovação Terapêutica, Universidade Federal de Pernambuco, Recife 50670-901, PE, Brazil
1 shared publication - Karen Loraine Macena Santos
Programa de Pós-Graduação em Inovação Terapêutica, Universidade Federal de Pernambuco, Recife, PE, 50670-901, Brazil
1 shared publication - Michelly Cristiny Pereira
Universidade Federal de Pernambuco
1 shared publication
Latest Publications
- 1 February 2025
- Published by Bentham Science Publishers Ltd. in Mini-Reviews in Organic Chemistry
- Vol. 22 (4) , 447-462
A Systematic Review of Electrochemical Sensing Devices Based on Metal-organic Frameworks for the Identification of Tumor Biomarkers
Background: Electrochemical sensors have attracted enormous interest in recent decades due to their relatively simple synthesis process, the possibility of modifications in their composition, and their wide application in detecting analytes. Methods: To achieve excellent performance, materials used in its construction must facilitate the transfer of electrons and provide a large surface area and excellent electrocatalytic activity. Because they are functional nanomaterials, metal-organic frameworks (MOFs) meet the criteria for application as a sensing material and can be used to build high-performance sensors for numerous applications. They play a relevant role in the early diagnosis of various neoplasms and tumor processes, thus providing better prognoses. Considering this universe, the present study focused on evaluating the application of these nanomaterials in the recognition of tumor biomarkers. Results: A systematic review of scientific publications was performed using the following descriptors "MOFs", "Metal-organic frameworks", "Biosensor", "Electrochemistry", and "Tumor Biomarker". Conclusion: Herein, we analyze recent innovations of MOF-based biosensors applied to the detection of tumor biomarkers, discussing how promising characteristics and properties of these materials were harnessed in the development of biosensors to provide a new contribution to future studies and the development of applied MOFs to electrochemical biosensing.
- 1 February 2025
- Published by Bentham Science Publishers Ltd. in Mini-Reviews in Organic Chemistry
- Vol. 22 (4) , 447-462
A Systematic Review of Electrochemical Sensing Devices Based on Metal-organic Frameworks for the Identification of Tumor Biomarkers
Background: Electrochemical sensors have attracted enormous interest in recent decades due to their relatively simple synthesis process, the possibility of modifications in their composition, and their wide application in detecting analytes. Methods: To achieve excellent performance, materials used in its construction must facilitate the transfer of electrons and provide a large surface area and excellent electrocatalytic activity. Because they are functional nanomaterials, metal-organic frameworks (MOFs) meet the criteria for application as a sensing material and can be used to build high-performance sensors for numerous applications. They play a relevant role in the early diagnosis of various neoplasms and tumor processes, thus providing better prognoses. Considering this universe, the present study focused on evaluating the application of these nanomaterials in the recognition of tumor biomarkers. Results: A systematic review of scientific publications was performed using the following descriptors "MOFs", "Metal-organic frameworks", "Biosensor", "Electrochemistry", and "Tumor Biomarker". Conclusion: Herein, we analyze recent innovations of MOF-based biosensors applied to the detection of tumor biomarkers, discussing how promising characteristics and properties of these materials were harnessed in the development of biosensors to provide a new contribution to future studies and the development of applied MOFs to electrochemical biosensing.
- 1 August 2024
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 20 (7) , 516-525
Biosensor Based on Zif-8-905% Metal-organic Nanocomposite and Carbon Nanotubes Associated with Concanavalin a for Detection of Alpha-fetoprotein
Introduction:: Lung carcinoma presents an aggressive evolution, with its carriers having reduced survival. Late diagnosis is one of the main factors of death. In the neoplasia in question, there is an established correlation with increases in Alpha-Fetoprotein (AFP) serum concentrations. Methos: Commonly used diagnostic methods are invasive or inaccessible. Therefore, a low-cost, non-invasive method would be extremely promising, and biomarkers can be used to achieve this goal. Electrochemical biosensors are a promising approach for detecting analytes of clinical interest using innovative bioreceptors. In this work, we obtained an electrochemical biosensor based on a hybrid ligand metal-organic structure (ZIF-8-905%) and functionalized carbon nanotubes (MWCNTs- COOH) in association with the lectin Concanavalin A (ConA), as a biorecognition element for detecting AFP in human serum from patients with lung carcinoma. Cyclic Voltammetry (CV), Square Wave Voltammetry (SWV), and Electrochemical Impedance Spectroscopy (EIS) were used to characterize the development of this biosensor. Microscopic analysis through Atomic Force Microscopy (AFM) revealed the formation of ConA-AFP complexes, pointing out the sensor's ability to identify the target analyte. Results: The blocking electron transfer effect in the electrode-redox pair interface assessed AFP detection. The ZIF-8-905%/MWCNTs-COOH/ConA platform exhibited a limit of detection (LOD) of 7.98 ng/mL, and a limit of quantification (LOQ) of 23.78ng/mL was also estimated. In addition, the biosensor showed excellent selectivity towards interfering biomolecules. Conclusion:: Therefore, the biosensor represents an efficient form of detection, contributing to research that aims to detect tumor biomarkers and ensure better prognoses.
- 1 August 2024
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 20 (7) , 516-525
Biosensor Based on Zif-8-905% Metal-organic Nanocomposite and Carbon Nanotubes Associated with Concanavalin a for Detection of Alpha-fetoprotein
Introduction:: Lung carcinoma presents an aggressive evolution, with its carriers having reduced survival. Late diagnosis is one of the main factors of death. In the neoplasia in question, there is an established correlation with increases in Alpha-Fetoprotein (AFP) serum concentrations. Methos: Commonly used diagnostic methods are invasive or inaccessible. Therefore, a low-cost, non-invasive method would be extremely promising, and biomarkers can be used to achieve this goal. Electrochemical biosensors are a promising approach for detecting analytes of clinical interest using innovative bioreceptors. In this work, we obtained an electrochemical biosensor based on a hybrid ligand metal-organic structure (ZIF-8-905%) and functionalized carbon nanotubes (MWCNTs- COOH) in association with the lectin Concanavalin A (ConA), as a biorecognition element for detecting AFP in human serum from patients with lung carcinoma. Cyclic Voltammetry (CV), Square Wave Voltammetry (SWV), and Electrochemical Impedance Spectroscopy (EIS) were used to characterize the development of this biosensor. Microscopic analysis through Atomic Force Microscopy (AFM) revealed the formation of ConA-AFP complexes, pointing out the sensor's ability to identify the target analyte. Results: The blocking electron transfer effect in the electrode-redox pair interface assessed AFP detection. The ZIF-8-905%/MWCNTs-COOH/ConA platform exhibited a limit of detection (LOD) of 7.98 ng/mL, and a limit of quantification (LOQ) of 23.78ng/mL was also estimated. In addition, the biosensor showed excellent selectivity towards interfering biomolecules. Conclusion:: Therefore, the biosensor represents an efficient form of detection, contributing to research that aims to detect tumor biomarkers and ensure better prognoses.