  • LVRT Capability Enhancement of Grid-Forming Inverters Under Current Saturation: A Dual-Reference Dynamic Cooperative Control Strategy

    by Dashuang Li, Qiuye Sun, Rui Wang, Pengcheng Wang, Zhengqi Sui, Peng Wang

    While transient stability enhancement for grid-forming inverters (GFMs) considering the impact of current-reference limiter has been widely studied, it remains insufficiently explored for GFMs employing circular current limiter due to the heightened complexity of power-angle curves under this limiting scheme. Meanwhile, based on the timing of grid voltage sag and current saturation, there are two types of current saturation model (CSM) for GFMs. A unified approach enhancing low voltage ride through (LVRT) capability across both CSMs has not been studied. To this end, this paper proposes a dual-reference dynamic coordination control strategy for GFMs to enhance its LVRT capability. Firstly, the explicit expression of output active power of GFMs incorporating dq-axis components of voltage reference is derived. Then, the transient synchronous stability control mechanism via power/voltage reference modulation is revealed by using EAC and phase-portrait analysis. Secondly, based on the obtained stability mechanism, a dual-reference dynamic coordination strategy is proposed, which can automatically trigger mode-specific strategies for two types of CSM. It dynamically adjusts power reference to guarantee the existence of equilibrium points (EPs) and modulates voltage reference to ensure the EP is stable and maximize transient stability margin. Finally, experimental results verify the effectiveness of the proposed strategy.


  • Dynamic Current Control Strategy of Grid-Connected Voltage Source Converters Feeding Constant Power Loads for Transient Stability Enhancement

    by Dashuang Li, Qiuye Sun, Rui Wang, Zhengqi Sui, Peng Wang

    The negative impedance characteristic of constant power loads (CPLs) can destabilize grid-connected voltage source converters (VSCs) by introducing positive feedback loops. To this end, this paper proposes a dynamic current control strategy for grid-connected VSCs with CPLs to enhance system transient synchronous stability (TSS). Firstly, a nonlinear phase-locked loop dynamic model is developed for VSCs. It explicitly incorporates the CPL impact, which indicates CPLs introduce coupling between the d-axis and q-axis components of VSC terminal voltage, and a positive feedback loop in VSC control scheme. Secondly, equal area criterion and phase-portrait analysis are used for qualitative and quantitative analysis to assess the CPL impact on TSS, respectively. The findings indicate the impact is related to the VSC output current. Therefore, a dynamic current control strategy for VSCs is proposed. It adds the current compensation term to neutralize CPL-induced destabilizing effects, guaranteeing the existence of stable equilibrium points that ensure both TSS and CPLs operation at rated power under grid faults. Meanwhile, a simple and fast VSC capacity calculation method is proposed. It can accurately calculate the required VSC capacity for achieving the above control objectives. Finally, simulation and experimental comparisons with existing methods verify the validity of the proposed strategy.


  • Enhance DFIG Capability for Simultaneous Active and Reactive Currents Injection During LVRT in Weak Grid Based on Coupling Elimination

    by Zhengqi Sui, Qiuye Sun, Rui Wang, Qianxiang Shen, Dashuang Li, Peng Wang

    The latest grid code indicates that, when a voltage drop occurs in the grid, the doubly fed induction generator (DFIG) needs to inject a certain amount of active current on the basis of meeting the reactive current demand to support frequency. However, in weak grid, further injecting active current can easily lead to small-signal instability issues. To address this, firstly, this paper analyzes the variation of the DFIG impedance with respect to changes in the current during low voltage ride through (LVRT). The result shows that, with the injection of active current, the phase of the DFIG output impedance decreases, which further reduces the system phase margin. Furthermore, this paper explains the reason for this change through theoretical deduction. Secondly, a q-axis voltage compensation-based control method is proposed. This method effectively eliminates the coupling of the DFIG impedance with current and the phase-locked loop (PLL), increasing the magnitude and phase of the impedance. Compared with existing methods, this method can significantly improve the operational capability of the DFIG during LVRT in weak grid, where both active and reactive currents are simultaneously injected. Furthermore, even if the system lacks fault detection capabilities, this method can still ensure stable operation of the DFIG under full active current injection condition during LVRT. Finally, the effectiveness and superiority of the proposed method are validated through simulations and experiments.


  • The Grid-Connected Inverter Stability Enhancement Control Based on Impedance Instability Region Elimination

    by Zhengqi Sui, Qiuye Sun, Rui Wang, Dashuang Li, Peng Wang

    The weak grid and high phase-locked loop (PLL) bandwidth can easily cause instability issues in the grid-connected Inverter (GCI) system. The present methods mainly enhance system stability by increasing the magnitude and phase of the GCI output impedance, but it cannot completely eliminate the “negative impedance” behavior of the GCI. It means that there is still a risk of instability in the system. Therefore, this article aims to propose a more general stability analysis method, revealing the instability conditions under negative impedance and providing a new insight for stability analysis and control strategy design. First, this article considers the broadband oscillation characteristics exhibited during GCI instability and proposes a new stability analysis method. This method indicates that the system instability is caused by the interaction between fundamental voltage and nonfundamental voltage. This interaction can exacerbate the oscillation of system voltage, ultimately leading to instability issues. This method provides a clear physical explanation for the mechanism of system instability. Second, a new impedance-based stability discrimination method is obtained, determining the conditions for GCI instability. This method can provide a clearer explanation of the present instability phenomena. Then, a compensation method based on q-axis voltage is proposed. This method achieves complete decoupling between the GCI impedance and voltage, effectively eliminating the instability region. Compared with existing methods, the method proposed can better ensure the stability of GCI under weak grid and high PLL bandwidth. Finally, the effectiveness of the proposed methods is verified through simulations and experiments.


  • Transient Stability Analysis and Improvement of Multiinverter-Based Microgrid

    by Dashuang Li, Qiuye Sun, Rui Wang, Xiaohan Yu

    Although the transient stability of grid has been widely researched, the existing approaches focus more on the transient stability of a single type of grid connected inverter, which are not suitable for the islanded microgrid with multiple types of inverters. Therefore, this article proposes a transient stability analysis and improvement method for a multiinverter-based microgrid (MIMG). First, a large signal synchronization model of MIMG is established, which fully considers the dynamic interactions among various types of inverters, the effects of inverter locations and the time-varying of load power. Then, the concept of the feasible region of current reference of grid-following inverters (GFLs) is proposed. It can ensure that the system has stable equilibrium points (EPs). Second, the attraction domain of EPs (ADEP) is calculated by constructing a new Lyapunov’s function of MIMG. Based on ADEP, a novel stability index is proposed, which considers inverter’s dynamics and has clear upper and lower limits to accurately evaluate the system stability. Furthermore, a novel current distribution method of GFLs is proposed, which can maximize the attraction domain’s radius of EPs and then enhance system transient stability in severe faults. Finally, simulations and experiments are performed to verify the performance of the method.


  • Transient Stability Analysis and Enhancement of Inverter-Based Microgrid Considering Current Limitation

    by Dashuang Li, Qiuye Sun, Rui Wang, Zhengqi Sui

    Affected by the current limitation, grid-forming inverters (GFMs) will transition to a current source under grid faults, which makes the inverter-based microgrid lose the voltage support and then be switched to a current source interconnection microgrid (CSIM). It may deteriorate the system's transient synchronization stability (TSS). This issue has not been studied previously. To this end, this article proposes an analysis and enhancement method of TSS of CSIM. First, a large signal synchronization model of CSIM is derived, which takes into account the effect of the current limitation strategy of GFMs and the dynamic interactions between GFMs and grid-following inverters (GFLs). Second, by constructing the Lyapunov energy function, the criterion of TSS is obtained and the impacts of parameters on stability are investigated. Based on the stability criterion, the feasible region of current references of GFLs is clearly described. Therefore, a dynamic current control method of GFLs is proposed. It can well address the absence of equilibrium points (EPs) and strengthen the transient stability. Meanwhile, a novel antiwindup strategy of GFMs considering synchronization stability constraint is proposed, which can contribute to the fault recovery of GFMs. Finally, simulation and experimental results verify the effectiveness of the proposed methods.


  • The Integrated Reference Region Analysis for Parallel DFIGs' Interfacing Inductors

    by Rui Wang, Xiaohan Yu, Qiuye Sun, Dashuang Li, Yonghao Gui, Peng Wang

    Although the traditional design of doubly-fed induction generators (DFIGs)’ interfacing inductors consider the peak ripple of the grid-side converter (GSC)’s output current, it does not consider the inductors' impact on DFIGs' small-signal stability. Located in series between the GSC and the stator, the inappropriate selection of the interfacing inductor can easily result to system instability. Therefore, this article first proposes the integrated reference region analysis for small wind farm's interfacing inductors to improve the traditional design method. First, a new detailed parallel DFIGs' small-signal model that considers output currents' coupling is built in d – q coordinate system with state-space approach. The model focuses on representing the operating states of parallel DFIGs in wind farm. Second, the linearized state-space matrix of parallel DFIGs is decomposed into nominal-value matrix and location matrix. Considering the traditional design requirements, the integrated reference region for interfacing inductor is proposed through spectral radius and bialternate matrix sum. It can provide better guidance for parameter selecting and stabilization method research works. Finally, the simulation and experimental results show that the proposed integrated reference region for parallel DFIGs' interfacing inductors is accurate and instructive.