Yidong Zhao

Yidong Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yidong Zhao has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dark-Blood Adiabatic T1ρ Mapping of the Heart Using Combined Non-Selective and Slice-Selective RF Pulses at 3T

    by Chiara Coletti, Joao Tourais, Anastasia Fotaki, Yidong Zhao, Yi Zhang, Christal van de Steeg-Henzen, Qian Tao, Claudia Prieto, Sebastian Weingärtner

    T1ρ mapping is emerging as a potential, contrast-free alternative to late gadolinium enhancement (LGE) for assessment of myocardial viability. However, strong signal contributions from the blood pool can impede quantitative evaluation at the (sub)endocardium. In this work, we study the effectiveness of dark-blood (DB) contrast in adiabatic T1ρ (T1ρ,adiab) mapping at 3T, using slice-selective and non-selective adiabatic spin-lock pulses. Adiabatic DB-T1ρ,adiab preparations consisted of an odd number of slice-selective adiabatic full passage (AFP) pulses, followed by a final, non-selective AFP pulse. This preparation induces T1ρ,adiab decay within the imaging slice while inverting the magnetization outside. A delay (δ) between preparation and imaging allowed for relaxation and inflow of the inverted blood to achieve DB contrast. Bias and precision of DB- and bright-blood (BB)-T1ρ,adiab were compared in phantom and in healthy subjects (n = 10). Blood suppression efficacy and apparent myocardial thickness in DB imaging were investigated in simulations, phantom, and in vivo. The clinical feasibility of DB-T1ρ,adiab mapping was evaluated in a small cohort of patients (n = 7) with suspected cardiovascular diseases. DB-T1ρ,adiab values were in agreement with reference BB-T1ρ,adiab values in phantom (myocardium-like vial BB: 219.27 ± 4.80 ms, DB: 218.09 ± 8.22 ms) and in healthy subjects (BB: 182.32 ± 28.27 ms, DB: 183.49 ± 45.54 ms). A moderate increase in intra-(wCVi,r) and inter-scan variability (wCVi¯) was observed in the DB method, compared with conventional BB imaging, for phantom and healthy subjects (in vivo wCVi,r BB: 15.51 ± 2.65%, DB: 24.82 ± 4.18%; in vivo wCVi¯ BB: 3.38 ± 0.86%, DB: 7.24 ± 2.55%). Longer delay times improved blood suppression in vivo for DB-T1ρ,adiab, albeit at increased intra-scan variability in phantom and in vivo (DB wCVi,r for δ = 0 ms: 4.90 ± 0.83% in phantom, 13.44 ± 2.91% in vivo, for δ = 600 ms: 8.14 ± 1.88% in phantom, 26.25 ± 5.19% in vivo). Average apparent myocardial thickness was slightly higher when using DB-T1ρ,adiab compared with BB-T1ρ,adiab (BB: 7.33 ± 2.05 mm, DB: 7.99 ± 2.46 mm). DB-T1ρ,adiab maps yielded comparable image quality to BB-T1ρ,adiab maps in patients. DB-T1ρ,adiab mapping represents an alternative to BB-T1ρ,adiab for myocardial assessment with the potential for improved visualization of the (sub-)endocardium.


  • Open Access

    Modeling Aleatoric Uncertainty in Cardiac MRI Segmentation: Probabilistic Detection and Contour Regression

    by Yidong Zhao, Yi Zhang, João Tourais, Sebastian Weingärtner, Avan Suinesiaputra, Alistair Young, Yuchi Han, Orlando Simonetti, Qian Tao

    Accurate segmentation of cardiac MRI is essential for assessment of cardiac function through biomarkers such as the left and right ventricular ejection fraction (LVEF, RVEF). Although AI methods have achieved high average segmentation accuracy, the precision of biomarkers for individual patients – quantified by estimation variance, remains critical for reliable diagnosis. Calibrated biomarkers, whose uncertainty accurately reflects the true variability, are highly desirable. However, existing evaluations predominantly focus on population-level segmentation accuracy, leaving biomarker-level uncertainty and calibration largely underexplored. Intrinsic anatomical ambiguity and annotation variability are major sources of biomarker variability and cannot be fully eliminated, even when training on a single annotation set. To address this, we propose a probabilistic segmentation framework that explicitly models aleatoric uncertainty with the goal of improving calibration in the biomarker space. The framework disentangles two key sources of uncertainty: (1) detection uncertainty, arising from ambiguous inclusion of basal or apical slices in 2D cardiac MRI, modeled via objectness probabilities; and (2) contour uncertainty, reflecting variability in ventricular boundary delineation, modeled through mean–variance regression of elliptic Fourier descriptors, a compact representation of closed contours. By propagating these uncertainties to derived biomarkers, the proposed method produces more informative and better-calibrated confidence estimates for ejection fraction. Compared to conventional pixel-wise approaches, our framework improves biomarker reliability, particularly in realistic settings dominated by annotation ambiguity and limited domain shift.

  • Open Access

    Efficient Interleaved Multi-Band Outer Volume Suppression for Highly Accelerated Simultaneous Multi-Slice Imaging of the Heart

    by Ayda Arami, Omer Burak Demirel, Toygan Kilic, Steen Moeller, Yidong Zhao, Yi Zhang, Qian Tao, Hildo J. Lamb, Mehmet Akçakaya, Sebastian Weingärtner

    In this work, we aimed to develop and evaluate multi-band outer volume suppression pulses for increased acceleration rates in simultaneous multi-slice accelerated cardiac MRI. MB-OVS pulses were constructed from a multi-band combination of two slab-selective saturation pulses and tested for various pulse shapes using Bloch simulation and phantom experiment. The MB-OVS pulses were interleaved between imaging pulses to ensure homogeneous suppression throughout the cardiac cycle/imaging window in vivo. Simultaneous multi-slice (SMS) CINE and first-pass myocardial perfusion scans with and without the proposed MB-OVS pulses were compared in terms of residual artifacts at high acceleration rates. Among the tested pulses, both Bloch simulation and phantom experiments showed that amplitude-optimized sinc pulses provided the best trade-off in suppression efficiency, the required B1+, SAR, and slab profile. CINE imaging with 5-fold SMS-OVS acceleration significantly outperformed imaging without MB-OVS, maintaining leakage-free image quality, even when adding 2-fold in-plane acceleration. SMS-OVS also enabled perfusion imaging in 9 slices with 1.7 × 1.7 mm2 resolution, achieving a 16-fold spatial-only acceleration while ensuring accurate contrast dynamics without leakage artifacts. Interleaved MB-OVS modules enabled thorough leakage artifact suppression in cardiac SMS-accelerated CINE and perfusion imaging, particularly at high acceleration rates. The proposed approach may be promising for unlocking further acceleration potential of SMS in cardiac imaging.


  • Reverse Imaging: Any-Sequence Generalization for Cardiac MRI Segmentation

    by Yidong Zhao, Yi Zhang, Tongyun Yang, Masa Bozic-Iven, Ayda Arami, Yuchi Han, Orlando Simonetti, Hui Xue, Peter Kellman, Sebastian Weingartner, et al.

  • Open Access

    Recurrent inference machine for medical image registration

    by Yi Zhang, Yidong Zhao, Hui Xue, Peter Kellman, Stefan Klein, Qian Tao


  • Open Access

    Improving Instance Optimization in Deformable Image Registration with Gradient Projection

    by Yi Zhang, Yidong Zhao, Qian Tao

    Deformable image registration is inherently a multi-objective optimization (MOO) problem, requiring a delicate balance between image similarity and deformation regularity. These conflicting objectives often lead to poor optimization outcomes, such as being trapped in unsatisfactory local minima or experiencing slow convergence. Deep learning methods have recently gained popularity in this domain due to their efficiency in processing large datasets and achieving high accuracy. However, they often underperform during test time compared to traditional optimization techniques, which further explore iterative, instance-specific gradient-based optimization. This performance gap is more pronounced when a distribution shift between training and test data exists. To address this issue, we focus on the instance optimization (IO) paradigm, which involves additional optimization for test-time instances based on a pre-trained model. IO effectively combines the generalization capabilities of deep learning with the fine-tuning advantages of instance-specific optimization. Within this framework, we emphasize the use of gradient projection to mitigate conflicting updates in MOO. This technique projects conflicting gradients into a common space, better aligning the dual objectives and enhancing optimization stability. We validate our method using a state-of-the-art foundation model on the 3D Brain inter-subject registration task (LUMIR) from the Learn2Reg 2024 Challenge. Our results show significant improvements over standard gradient descent, leading to more accurate and reliable registration results.

  • Open Access

    Bayesian Uncertainty Estimation by Hamiltonian Monte Carlo: Applications to Cardiac MRI Segmentation

    by Yidong Zhao, João Tourais, Iain Pierce, Christian Nitsche, Thomas A. Treibel, Sebastian WeingärTner, Artur M. Schweidtmann, Qian Tao

    Deep learning (DL)-based methods have achieved state-of-the-art performance for many medical image segmentation tasks. Nevertheless, recent studies show that deep neural net- works (DNNs) can be miscalibrated and overconfident, leading to ”silent failures” that are risky for clinical applications. Bayesian DL provides an intuitive approach to DL failure de- tection, based on posterior probability estimation. However, the posterior is intractable for large medical image segmentation DNNs. To tackle this challenge, we propose a Bayesian learning framework using Hamiltonian Monte Carlo (HMC), tempered by cold posterior (CP) to accommodate medical data augmentation, named HMC-CP. For HMC compu- tation, we further propose a cyclical annealing strategy, capturing both local and global geometries of the posterior distribution, enabling highly efficient Bayesian DNN training with the same computational budget as training a single DNN. The resulting Bayesian DNN outputs an ensemble segmentation along with the segmentation uncertainty. We evaluate the proposed HMC-CP extensively on cardiac magnetic resonance image (MRI) segmentation, using in-domain steady-state free precession (SSFP) cine images as well as out-of-domain datasets of quantitative T1 and T2 mapping. Our results show that the proposed method improves both segmentation accuracy and uncertainty estimation for in- and out-of-domain data, compared with well-established baseline methods such as Monte Carlo Dropout and Deep Ensembles. Additionally, we establish a conceptual link between HMC and the commonly known stochastic gradient descent (SGD) and provide general insight into the uncertainty of DL. This uncertainty is implicitly encoded in the training dynamics but often overlooked. With reliable uncertainty estimation, our method provides a promising direction toward trustworthy DL in clinical applications. We release our code in https://gitlab.tudelft.nl/yidongzhao/hmc_uncertainty