Zhang Tu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhang Tu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Liang Li
Huazhong University of Science and Technology
3 shared publications - Yiliang Lv
Huazhong University of Science and Technology
3 shared publications - Yanping Ye
Wuhan National High Magnetic Field Center and State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Wuhan, China
2 shared publications - Hongfa Ding
Wuhan High Magnetic Field Center, Huazhong University of Science and Technology, Wuhan 430074, China
1 shared publication - Ronggang Chen
Wuhan National High Magnetic Field Center and State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Wuhan, China
1 shared publication - Tao Peng
Huazhong University of Science and Technology
1 shared publication
Latest Publications
- 9 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-7
Design and Experiment of Post-Assembly Magnetization System for a 160-kW Interior Permanent-Magnet Motor
It is well-known that post-assembly magnetization could simplify the manufacturing process and enhance the performance of interior permanent-magnet motor (IPM). However, due to the complexity of magnetic circuit structures of IPMs, this technique is hard to achieve because of difficulties in generating an appropriate magnetization field and developing high-strength coils. Consequently, the majority of existing researches still stay in simulation stage with low-power motors. In this research background, this paper mainly focuses on studying post-assembly magnetization of a high-power IPM. Based on a magnetic characteristics test of N42UH Nd–Fe–B permanent magnet material, the paper researches impact of skewed rotor, electromagnetic design and structure design of coils. Finally, a post-assembly magnetization system for 160 kW IPM is created to demonstrate the effectiveness of this system.
- 9 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-7
Design and Experiment of Post-Assembly Magnetization System for a 160-kW Interior Permanent-Magnet Motor
It is well-known that post-assembly magnetization could simplify the manufacturing process and enhance the performance of interior permanent-magnet motor (IPM). However, due to the complexity of magnetic circuit structures of IPMs, this technique is hard to achieve because of difficulties in generating an appropriate magnetization field and developing high-strength coils. Consequently, the majority of existing researches still stay in simulation stage with low-power motors. In this research background, this paper mainly focuses on studying post-assembly magnetization of a high-power IPM. Based on a magnetic characteristics test of N42UH Nd–Fe–B permanent magnet material, the paper researches impact of skewed rotor, electromagnetic design and structure design of coils. Finally, a post-assembly magnetization system for 160 kW IPM is created to demonstrate the effectiveness of this system.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-6
Experimental and Simulation Study on Fast Cooling Method of Pulsed Magnetic Coil Based on Heat Pipe
The repeated discharge frequency is one of the important factors affecting the industrial application of pulsed magnets. In order to increase the repeated discharge frequency of pulsed magnets, a rapid cooling method based on heat pipes was proposed. By placing heat pipes between the layers of magnets, the influence of reinforcing materials with very low thermal conductivity can be overcome and the heat dissipation efficiency of magnets can be improved. An experimental model of heat pipe is established in this article. On this test bench, the heat dissipation performance of heat pipe was verified firstly. Besides, the influence of different flattening thickness, flattening length and heat load on the performance of heat pipe was investigated. The experimental results show that when the input power of a single heat pipe is 40 W, the heat source temperature can be stabilized below 65°C. Surface insulation of conductor will weaken the heat dissipation effect, but in a certain range, the heat pipe can still effectively control the temperature of the heat source. The smaller the flattening thickness and the longer the flattening length, the worse the thermal conductivity of the heat pipe. The thermal conductivity of heat pipe increases first and then decreases with the increasing input power, that is to say, the heat pipe has an optimal working power range. In this article, a rapid cooling scheme based on heat pipes was designed for 3 T saddle-shaped pulsed magnets and numerical simulation was carried out. The simulation results show that the repeated discharge frequency can reach four times per minute, which shows the effectiveness and high efficiency of heat pipes for heat dissipation of pulsed magnets.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-6
Experimental and Simulation Study on Fast Cooling Method of Pulsed Magnetic Coil Based on Heat Pipe
The repeated discharge frequency is one of the important factors affecting the industrial application of pulsed magnets. In order to increase the repeated discharge frequency of pulsed magnets, a rapid cooling method based on heat pipes was proposed. By placing heat pipes between the layers of magnets, the influence of reinforcing materials with very low thermal conductivity can be overcome and the heat dissipation efficiency of magnets can be improved. An experimental model of heat pipe is established in this article. On this test bench, the heat dissipation performance of heat pipe was verified firstly. Besides, the influence of different flattening thickness, flattening length and heat load on the performance of heat pipe was investigated. The experimental results show that when the input power of a single heat pipe is 40 W, the heat source temperature can be stabilized below 65°C. Surface insulation of conductor will weaken the heat dissipation effect, but in a certain range, the heat pipe can still effectively control the temperature of the heat source. The smaller the flattening thickness and the longer the flattening length, the worse the thermal conductivity of the heat pipe. The thermal conductivity of heat pipe increases first and then decreases with the increasing input power, that is to say, the heat pipe has an optimal working power range. In this article, a rapid cooling scheme based on heat pipes was designed for 3 T saddle-shaped pulsed magnets and numerical simulation was carried out. The simulation results show that the repeated discharge frequency can reach four times per minute, which shows the effectiveness and high efficiency of heat pipes for heat dissipation of pulsed magnets.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-6
Investigation on Saturated Magnetization Characteristics of Anisotropic NdFeB Permanent Magnet in Post-Assembly Magnetization Application
Saturated magnetization of permanent magnets depends on the intensity and direction of the applied pulsed magnetization field. Uneven distribution of magnetization field may results in local unsaturation, especially during the post-assembly magnetization process. Researchers have found that the saturated magnetization field intensity increases with the angle between the magnetization field and the easy axis of anisotropic permanent magnets. When the angle is equal to 90°, the saturated magnetization field tends to be infinite. This article studies the saturated magnetization characteristics of anisotropic NdFeB. The magnetization experiment platform which can adjust the direction of magnetization field is designed, and the saturated magnetization characteristic curves of sintered NdFeB magnet in fields of different intensity and angle are measured. The experimental results show that the saturated magnetization field intensity increases with the angle between the magnetization field and the easy axis, and when the angle is greater than 70°, magnetization field as high as 10 T cannot make the permanent magnet be saturated. The model of the saturated magnetization field along the easy axis and deviate from the easy axis are proposed based on intrinsic coercivity, demagnetization field, and an effective field coefficient, which fits the experiment results well. The saturation magnetization criterion of permanent magnetic material is proposed. Combined with the simulation of the intensity and direction of the pulsed magnetization field, we can judge the saturation region of permanent magnetic poles, thus helping us to design the post-assembly magnetization coils.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-6
Investigation on Saturated Magnetization Characteristics of Anisotropic NdFeB Permanent Magnet in Post-Assembly Magnetization Application
Saturated magnetization of permanent magnets depends on the intensity and direction of the applied pulsed magnetization field. Uneven distribution of magnetization field may results in local unsaturation, especially during the post-assembly magnetization process. Researchers have found that the saturated magnetization field intensity increases with the angle between the magnetization field and the easy axis of anisotropic permanent magnets. When the angle is equal to 90°, the saturated magnetization field tends to be infinite. This article studies the saturated magnetization characteristics of anisotropic NdFeB. The magnetization experiment platform which can adjust the direction of magnetization field is designed, and the saturated magnetization characteristic curves of sintered NdFeB magnet in fields of different intensity and angle are measured. The experimental results show that the saturated magnetization field intensity increases with the angle between the magnetization field and the easy axis, and when the angle is greater than 70°, magnetization field as high as 10 T cannot make the permanent magnet be saturated. The model of the saturated magnetization field along the easy axis and deviate from the easy axis are proposed based on intrinsic coercivity, demagnetization field, and an effective field coefficient, which fits the experiment results well. The saturation magnetization criterion of permanent magnetic material is proposed. Combined with the simulation of the intensity and direction of the pulsed magnetization field, we can judge the saturation region of permanent magnetic poles, thus helping us to design the post-assembly magnetization coils.