Syarizal Fonna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Syarizal Fonna has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Israr B. M. Ibrahim
Universitas Syiah Kuala
2 shared publicationsMuhibul Jamal
Universitas Syiah Kuala
2 shared publications- Muttaqin Hasan
Department of Civil Engineering, Universitas Syiah Kuala, Banda Aceh 23111, Indonesia
2 shared publications Syifaul Huzni
Universitas Syiah Kuala
2 shared publications- Taufiq Saidi
Department of Civil Engineering, Universitas Syiah Kuala, Banda Aceh 23111, Indonesia
2 shared publications Ahmad Zaki
Universitas Muhammadiyah Yogyakarta
1 shared publication
Latest Publications
- 2 June 2026
- Published by Springer Nature
- p. 331-342
Protection of Carbon Steel from Atmospheric Corrosion Using Polymer-Based Materials in the Banda Aceh Environment
- 2 June 2026
- Published by Springer Nature
- p. 331-342
Protection of Carbon Steel from Atmospheric Corrosion Using Polymer-Based Materials in the Banda Aceh Environment
- Open Access
Carbonation Depth, Corrosion Assessment, Repairing, and Strengthening of 49-Year-Old Marine Reinforced Concrete Structures
This study aims to present the results from the assessment of carbonation depth, corrosion, and compressive strength of real marine structures in a 49-year-old gas processing industry. The assessment was achieved through visual observations and non-destructive tests, including rebound hammer test, ultrasonic pulse velocity (UPV) test, and potential corrosion mapping, conducted in the field. Several cylindrical samples were also cored to test the concrete compressive strength and carbonation depth. The results were subsequently used to calculate the remaining load-bearing capacity of the structures. The observations and measurements showed that carbonation depth ranged from 0 to 63% of the concrete cover, and potential corrosion was at a low to medium level in areas where corrosion had not occurred, while the actual compressive strength is still above the design strength. Moreover, based on the UPV test, the pulse velocity of the concrete is around 3600 m/s, indicating a good concrete quality. Meanwhile, severe corrosion of reinforcing steel occurred locally and only at certain places, which caused a very significant reduction in the diameter and cracks as well as spalling of the concrete cover. The process further led to a significant reduction in the load-bearing capacity. Therefore, repairing and strengthening of the structures were proposed using epoxy resin with corrosion inhibitor, cementitious, polymer-modified repair mortar containing reactive micro-silica, Carbon Fiber Reinforced Polymer (CFRP) rods, and CFRP sheets. The proposed method can be applied to these structures and also serves as a reference for repairing and strengthening other structures experiencing the same issue.
Open AccessCarbonation Depth, Corrosion Assessment, Repairing, and Strengthening of 49-Year-Old Marine Reinforced Concrete Structures
This study aims to present the results from the assessment of carbonation depth, corrosion, and compressive strength of real marine structures in a 49-year-old gas processing industry. The assessment was achieved through visual observations and non-destructive tests, including rebound hammer test, ultrasonic pulse velocity (UPV) test, and potential corrosion mapping, conducted in the field. Several cylindrical samples were also cored to test the concrete compressive strength and carbonation depth. The results were subsequently used to calculate the remaining load-bearing capacity of the structures. The observations and measurements showed that carbonation depth ranged from 0 to 63% of the concrete cover, and potential corrosion was at a low to medium level in areas where corrosion had not occurred, while the actual compressive strength is still above the design strength. Moreover, based on the UPV test, the pulse velocity of the concrete is around 3600 m/s, indicating a good concrete quality. Meanwhile, severe corrosion of reinforcing steel occurred locally and only at certain places, which caused a very significant reduction in the diameter and cracks as well as spalling of the concrete cover. The process further led to a significant reduction in the load-bearing capacity. Therefore, repairing and strengthening of the structures were proposed using epoxy resin with corrosion inhibitor, cementitious, polymer-modified repair mortar containing reactive micro-silica, Carbon Fiber Reinforced Polymer (CFRP) rods, and CFRP sheets. The proposed method can be applied to these structures and also serves as a reference for repairing and strengthening other structures experiencing the same issue.
- 5 February 2024
- Published by Springer Nature
- p. 603-610
PDE-Constrained Inverse Analysis Using Bayesian Optimization for Finding Hidden Corrosion Given Partial Surface Information
- 5 February 2024
- Published by Springer Nature
- p. 603-610
PDE-Constrained Inverse Analysis Using Bayesian Optimization for Finding Hidden Corrosion Given Partial Surface Information
- 5 February 2024
- Published by Springer Nature
- p. 65-74
Assessment and Strengthening of Cement Plant Clinker Silo Structure Due to Corrosion of Reinforcing Bars
- 5 February 2024
- Published by Springer Nature
- p. 65-74
Assessment and Strengthening of Cement Plant Clinker Silo Structure Due to Corrosion of Reinforcing Bars
- 5 February 2024
- Published by Springer Nature
- p. 85-93
Study the Effect of Hyperparameters on Performance of BEIA to Detect Corrosion in Reinforced Concrete
- 5 February 2024
- Published by Springer Nature
- p. 85-93
Study the Effect of Hyperparameters on Performance of BEIA to Detect Corrosion in Reinforced Concrete