Yea-Ji Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yea-Ji Lee has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Chung-Sik Oh
Department of Anesthesiology and Pain Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea
2 shared publications - Tae-Yop Kim
Department of Anesthesiology and Pain Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Republic of Korea
2 shared publications - Bon-Nyeo Koo
Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea
1 shared publication - Eun-Young Joo
Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
1 shared publication - Hyun Jung Koh
Department of Anesthesiology and Pain Medicine, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea
1 shared publication - Hyunjee Kim
Department of Anesthesiology and Pain Medicine, School of Medicine, Kyungpook National University, Daegu, Republic of Korea
1 shared publication
Latest Publications
- 13 February 2026
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 43 (5) , 377-385
Incidence of transient sinus pause in cardiac rhythm increases with the use of hyperangulated videolaryngoscope blade compared to standard angle blade during tracheal intubation
BACKGROUND: The hyperanglulated videolaryngoscope blade may exert different forces on the larynx compared to the standard angle blade, potentially leading to haemodynamic changes, particularly in cardiac rhythm. OBJECTIVE: This study aimed to investigate the impact of the hyperangulated blade on haemodynamic changes during tracheal intubation. DESIGN: A prospective randomised controlled trial. SETTING: Tertiary, university hospital, single centre. PATIENTS: A total of 134 patients scheduled for general anaesthesia were included in the final analysis INTERVENTION: Tracheal intubation using either a standard angle videolaryngoscope blade (Standard group) or a hyperangulated blade (Hyperangulated group). MAIN OUTCOME MEASURES: The occurrence of a transient decrease in heart rate or a transient sinus pause during tracheal intubation was recorded. RESULTS: The incidence of transient sinus pause was significantly higher in the Hyperangulated group compared to the Standard group (19% vs. 4%, respectively, P = 0.009). The percentage of the glottic opening score was significantly higher, and the incidence of backward, upward, and rightward pressure was significantly lower in the Hyperangulated group. The incidences of direct epiglottis lifting was significantly higher in the Hyperangulated group, and the total length of time of the blade in the mouth was significantly longer in the Hyperangulated group. Multivariate logistic analysis identified the use of a hyperangulated blade as an independent predictor of transient sinus pause during tracheal intubation (odds ratio = 5.73, 95% confidence interval = 1.53 to 21.53; P = 0.010). CONCLUSION: The hyperangulated videolaryngoscope blade is associated with a higher incidence of transient sinus pause than the standard angle blade during tracheal intubation. TRIAL REGISTRATION: Clinical Research Information Service. Korea Centers for Disease Control and Prevention, Ministry of Health and Welfare (Republic of Korea). (Identifier: KCT0006534). http://cris.nih.go.kr.
- 13 February 2026
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 43 (5) , 377-385
Incidence of transient sinus pause in cardiac rhythm increases with the use of hyperangulated videolaryngoscope blade compared to standard angle blade during tracheal intubation
BACKGROUND: The hyperanglulated videolaryngoscope blade may exert different forces on the larynx compared to the standard angle blade, potentially leading to haemodynamic changes, particularly in cardiac rhythm. OBJECTIVE: This study aimed to investigate the impact of the hyperangulated blade on haemodynamic changes during tracheal intubation. DESIGN: A prospective randomised controlled trial. SETTING: Tertiary, university hospital, single centre. PATIENTS: A total of 134 patients scheduled for general anaesthesia were included in the final analysis INTERVENTION: Tracheal intubation using either a standard angle videolaryngoscope blade (Standard group) or a hyperangulated blade (Hyperangulated group). MAIN OUTCOME MEASURES: The occurrence of a transient decrease in heart rate or a transient sinus pause during tracheal intubation was recorded. RESULTS: The incidence of transient sinus pause was significantly higher in the Hyperangulated group compared to the Standard group (19% vs. 4%, respectively, P = 0.009). The percentage of the glottic opening score was significantly higher, and the incidence of backward, upward, and rightward pressure was significantly lower in the Hyperangulated group. The incidences of direct epiglottis lifting was significantly higher in the Hyperangulated group, and the total length of time of the blade in the mouth was significantly longer in the Hyperangulated group. Multivariate logistic analysis identified the use of a hyperangulated blade as an independent predictor of transient sinus pause during tracheal intubation (odds ratio = 5.73, 95% confidence interval = 1.53 to 21.53; P = 0.010). CONCLUSION: The hyperangulated videolaryngoscope blade is associated with a higher incidence of transient sinus pause than the standard angle blade during tracheal intubation. TRIAL REGISTRATION: Clinical Research Information Service. Korea Centers for Disease Control and Prevention, Ministry of Health and Welfare (Republic of Korea). (Identifier: KCT0006534). http://cris.nih.go.kr.
- Open Access
- 1 January 2026
- Published by Wiley in International Journal Of Clinical Practice
- Vol. 2026 (1) , 7343700
The Influence of Body Mass Index on the Adjustment of Supraglottic Airway Device in Lithotomy With Trendelenburg Position: A Prospective Observational Study
Background: This study aimed to compare different methods for adjusting the supraglottic airway device (SGA) to achieve adequate ventilation in patients with normal and high body mass index (BMI). Methods: A total of 117 patients who were ≥ 20 years of age and scheduled to undergo general anesthesia under lithotomy with a 10° Trendelenburg position during operation were enrolled, and the patients were categorized into two groups based on their BMI: those with a BMI of < 25 kg/m 2 (64 patients for normal BMI group) and those with a BMI ≥ 25 kg/m 2 (53 patients for high BMI group). After SGA insertion, two adjustment methods (additional push‐in with neck extension or pull‐out of the SGA) were applied to ensure adequate ventilation. The primary endpoint was the incidence of additional SGA adjustments after anesthesia. Results: The overall incidence of additional SGA adjustment for adequate ventilation was significantly higher in the high BMI group than in the normal BMI group (40 (75.5%) vs. 32 (50.0%), p = 0.009). In the multivariable logistic regression analysis, the BMI was identified as an independent risk factor for additional SGA adjustment (OR = 1.29 (1.12–1.48), p < 0.001), and the area under the receiver operating curve for BMI was 0.71 (0.62–0.81) ( p < 0.001). Conclusions: The additional SGA adjustments may be influenced by the BMI, and the depth of the SGA may change during positive pressure ventilation in the lithotomy with Trendelenburg position in patients with a high BMI. Trial Registration: Clinical Trial Registry of Korea: KCT0005029
- 1 January 2026
- Published by Wiley in International Journal Of Clinical Practice
- Vol. 2026 (1) , 7343700
Open AccessThe Influence of Body Mass Index on the Adjustment of Supraglottic Airway Device in Lithotomy With Trendelenburg Position: A Prospective Observational Study
Background: This study aimed to compare different methods for adjusting the supraglottic airway device (SGA) to achieve adequate ventilation in patients with normal and high body mass index (BMI). Methods: A total of 117 patients who were ≥ 20 years of age and scheduled to undergo general anesthesia under lithotomy with a 10° Trendelenburg position during operation were enrolled, and the patients were categorized into two groups based on their BMI: those with a BMI of < 25 kg/m 2 (64 patients for normal BMI group) and those with a BMI ≥ 25 kg/m 2 (53 patients for high BMI group). After SGA insertion, two adjustment methods (additional push‐in with neck extension or pull‐out of the SGA) were applied to ensure adequate ventilation. The primary endpoint was the incidence of additional SGA adjustments after anesthesia. Results: The overall incidence of additional SGA adjustment for adequate ventilation was significantly higher in the high BMI group than in the normal BMI group (40 (75.5%) vs. 32 (50.0%), p = 0.009). In the multivariable logistic regression analysis, the BMI was identified as an independent risk factor for additional SGA adjustment (OR = 1.29 (1.12–1.48), p < 0.001), and the area under the receiver operating curve for BMI was 0.71 (0.62–0.81) ( p < 0.001). Conclusions: The additional SGA adjustments may be influenced by the BMI, and the depth of the SGA may change during positive pressure ventilation in the lithotomy with Trendelenburg position in patients with a high BMI. Trial Registration: Clinical Trial Registry of Korea: KCT0005029
- Open Access
- 1 February 2024
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 77 (1) , 5-30
Korean clinical practice guidelines for diagnostic and procedural sedation
Safe and effective sedation depends on various factors, such as the choice of sedatives, sedation techniques used, experience of the sedation provider, degree of sedation-related education and training, equipment and healthcare worker availability, the patient’s underlying diseases, and the procedure being performed. The purpose of these evidence-based multidisciplinary clinical practice guidelines is to ensure the safety and efficacy of sedation, thereby contributing to patient safety and ultimately improving public health. These clinical practice guidelines comprise 15 key questions covering various topics related to the following: the sedation providers; medications and equipment available; appropriate patient selection; anesthesiologist referrals for high-risk patients; pre-sedation fasting; comparison of representative drugs used in adult and pediatric patients; respiratory system, cardiovascular system, and sedation depth monitoring during sedation; management of respiratory complications during pediatric sedation; and discharge criteria. The recommendations in these clinical practice guidelines were systematically developed to assist providers and patients in sedation-related decision making for diagnostic and therapeutic examinations or procedures. Depending on the characteristics of primary, secondary, and tertiary care institutions as well as the clinical needs and limitations, sedation providers at each medical institution may choose to apply the recommendations as they are, modify them appropriately, or reject them completely.
- 1 February 2024
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 77 (1) , 5-30
Open AccessKorean clinical practice guidelines for diagnostic and procedural sedation
Safe and effective sedation depends on various factors, such as the choice of sedatives, sedation techniques used, experience of the sedation provider, degree of sedation-related education and training, equipment and healthcare worker availability, the patient’s underlying diseases, and the procedure being performed. The purpose of these evidence-based multidisciplinary clinical practice guidelines is to ensure the safety and efficacy of sedation, thereby contributing to patient safety and ultimately improving public health. These clinical practice guidelines comprise 15 key questions covering various topics related to the following: the sedation providers; medications and equipment available; appropriate patient selection; anesthesiologist referrals for high-risk patients; pre-sedation fasting; comparison of representative drugs used in adult and pediatric patients; respiratory system, cardiovascular system, and sedation depth monitoring during sedation; management of respiratory complications during pediatric sedation; and discharge criteria. The recommendations in these clinical practice guidelines were systematically developed to assist providers and patients in sedation-related decision making for diagnostic and therapeutic examinations or procedures. Depending on the characteristics of primary, secondary, and tertiary care institutions as well as the clinical needs and limitations, sedation providers at each medical institution may choose to apply the recommendations as they are, modify them appropriately, or reject them completely.