Hannes Widing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hannes Widing has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Carl Sjödin
Department of Anaesthesiology and Intensive Care, Region Västra Götaland, Sahlgrenska University Hospital, Gothenburg, Sweden
1 shared publication - Christian Rylander
Anesthesiology and Intensive Care, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
1 shared publication Elena Chiodaroli
Hedenstierna Laboratory, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
1 shared publicationFelicia Olsson Lindstrand
Department of Anaesthesiology and Intensive Care, Region Västra Götaland Sahlgrenska University Hospital Gothenburg Sweden
1 shared publicationGaetano Perchiazzi
Hedenstierna Laboratory, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden
1 shared publicationKatarina Hallén
Department of Anesthesiology and Intensive Care Medicine, Region Västra Götaland, Sahlgrenska University Hospital/Östra, Gothenburg, Sweden
1 shared publication
Latest Publications
- 24 September 2026
- Published by Wiley in Nursing in Critical Care
- Vol. 31 (6)
Peripheral Perfusion: The Missing Physiological Variable in ICU Pulse Oximetry Accuracy Studies
- 24 September 2026
- Published by Wiley in Nursing in Critical Care
- Vol. 31 (6)
Peripheral Perfusion: The Missing Physiological Variable in ICU Pulse Oximetry Accuracy Studies
- Open Access
- 11 June 2026
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 40 (5) , 1177-1188
Esophageal pressures in supine and prone position: evaluation using high-resolution manometry
Esophageal pressure (PES), used as a substitute for pleural pressure in calculations of respiratory mechanics, are complex and influenced by several factors. High-resolution manometry (HRM) provides pressure readings over the esophageal length, which makes it possible to identify factors other than respiratory mechanics that influence esophageal pressure. The aim of this study was to describe and explore esophageal pressure in prone and supine position at different ventilatory settings. PES was measured using HRM in 20 mechanically ventilated patients before start of spinal surgery. PEEP of 5 and 12 cmH 2 O were used in supine and prone position while data were recorded continuously. Mean end-expiratory (PES EE ) and tidal variation of esophageal pressures (ΔPES) from sensors in different esophageal regions were compared including a selection of sensors with theoretically optimal pressure readings (PES OPT ). PES EE was significantly lower (MD 3.2–5.7), ΔPES was significantly higher (MD 0.8–1.6 cmH 2 O) and cardiac oscillations were significantly smaller in prone compared to supine position. Differences were dependent on PEEP level and regions of esophagus included. Mean within patient variability of PES EE and ΔPES was 38–540% depending on PEEP level and body position. End-expiratory PES OPT was lower than mean PES EE from larger esophageal regions and less variable. A large variation in PES is seen in both supine and prone position but depends on which sensors are included in calculations of PES. There are significant differences in absolute pressures and in influence from mediastinal organs between supine and prone position.
- 11 June 2026
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 40 (5) , 1177-1188
Open AccessEsophageal pressures in supine and prone position: evaluation using high-resolution manometry
Esophageal pressure (PES), used as a substitute for pleural pressure in calculations of respiratory mechanics, are complex and influenced by several factors. High-resolution manometry (HRM) provides pressure readings over the esophageal length, which makes it possible to identify factors other than respiratory mechanics that influence esophageal pressure. The aim of this study was to describe and explore esophageal pressure in prone and supine position at different ventilatory settings. PES was measured using HRM in 20 mechanically ventilated patients before start of spinal surgery. PEEP of 5 and 12 cmH 2 O were used in supine and prone position while data were recorded continuously. Mean end-expiratory (PES EE ) and tidal variation of esophageal pressures (ΔPES) from sensors in different esophageal regions were compared including a selection of sensors with theoretically optimal pressure readings (PES OPT ). PES EE was significantly lower (MD 3.2–5.7), ΔPES was significantly higher (MD 0.8–1.6 cmH 2 O) and cardiac oscillations were significantly smaller in prone compared to supine position. Differences were dependent on PEEP level and regions of esophagus included. Mean within patient variability of PES EE and ΔPES was 38–540% depending on PEEP level and body position. End-expiratory PES OPT was lower than mean PES EE from larger esophageal regions and less variable. A large variation in PES is seen in both supine and prone position but depends on which sensors are included in calculations of PES. There are significant differences in absolute pressures and in influence from mediastinal organs between supine and prone position.
- Open Access
- 5 February 2024
- Published by Springer Nature in Intensive Care Medicine Experimental
- Vol. 12 (1) , 1-10
Positive end-expiratory pressure limits inspiratory effort through modulation of the effort-to-drive ratio: an experimental crossover study
Background: How assisted spontaneous breathing should be used during acute respiratory distress syndrome is questioned. Recent evidence suggests that high positive end-expiratory pressure (PEEP) may limit the risk of patient self-inflicted lung injury (P-SILI). The aim of this study was to assess the effects of PEEP on esophageal pressure swings, inspiratory drive, and the neuromuscular efficiency of ventilation. We hypothesized that high PEEP would reduce esophageal pressure swings, regardless of inspiratory drive changes, by modulating the effort-to-drive ratio (EDR). This was tested retrospectively in an experimental animal crossover study. Anesthetized pigs (n = 15) were subjected to mild to moderate lung injury and different PEEP levels were applied, changing PEEP from 0 to 15 cmH2O and back to 0 cmH2O in steps of 3 cmH2O. Airway pressure, esophageal pressure (Pes), and electric activity of the diaphragm (Edi) were collected. The EDR was calculated as the tidal change in Pes divided by the tidal change in Edi. Statistical differences were tested using the Wilcoxon signed-rank test. Results: Inspiratory esophageal pressure swings decreased from − 4.2 ± 3.1 cmH2O to − 1.9 ± 1.5 cmH2O (p < 0.01), and the mean EDR fell from − 1.12 ± 1.05 cmH2O/µV to − 0.24 ± 0.20 (p < 0.01) as PEEP was increased from 0 to 15 cmH2O. The EDR was significantly correlated to the PEEP level (rs = 0.35, p < 0.01). Conclusions: Higher PEEP limits inspiratory effort by modulating the EDR of the respiratory system. These findings indicate that PEEP may be used in titration of the spontaneous impact on ventilation and in P-SILI risk reduction, potentially facilitating safe assisted spontaneous breathing. Similarly, ventilation may be shifted from highly spontaneous to predominantly controlled ventilation using PEEP. These findings need to be confirmed in clinical settings.
- 5 February 2024
- Published by Springer Nature in Intensive Care Medicine Experimental
- Vol. 12 (1) , 1-10
Open AccessPositive end-expiratory pressure limits inspiratory effort through modulation of the effort-to-drive ratio: an experimental crossover study
Background: How assisted spontaneous breathing should be used during acute respiratory distress syndrome is questioned. Recent evidence suggests that high positive end-expiratory pressure (PEEP) may limit the risk of patient self-inflicted lung injury (P-SILI). The aim of this study was to assess the effects of PEEP on esophageal pressure swings, inspiratory drive, and the neuromuscular efficiency of ventilation. We hypothesized that high PEEP would reduce esophageal pressure swings, regardless of inspiratory drive changes, by modulating the effort-to-drive ratio (EDR). This was tested retrospectively in an experimental animal crossover study. Anesthetized pigs (n = 15) were subjected to mild to moderate lung injury and different PEEP levels were applied, changing PEEP from 0 to 15 cmH2O and back to 0 cmH2O in steps of 3 cmH2O. Airway pressure, esophageal pressure (Pes), and electric activity of the diaphragm (Edi) were collected. The EDR was calculated as the tidal change in Pes divided by the tidal change in Edi. Statistical differences were tested using the Wilcoxon signed-rank test. Results: Inspiratory esophageal pressure swings decreased from − 4.2 ± 3.1 cmH2O to − 1.9 ± 1.5 cmH2O (p < 0.01), and the mean EDR fell from − 1.12 ± 1.05 cmH2O/µV to − 0.24 ± 0.20 (p < 0.01) as PEEP was increased from 0 to 15 cmH2O. The EDR was significantly correlated to the PEEP level (rs = 0.35, p < 0.01). Conclusions: Higher PEEP limits inspiratory effort by modulating the EDR of the respiratory system. These findings indicate that PEEP may be used in titration of the spontaneous impact on ventilation and in P-SILI risk reduction, potentially facilitating safe assisted spontaneous breathing. Similarly, ventilation may be shifted from highly spontaneous to predominantly controlled ventilation using PEEP. These findings need to be confirmed in clinical settings.