Luciano Chiominto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Luciano Chiominto has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Emanuela Natale
Department of Industrial and Information Engineering and Economics, University of L’Aquila, 67100 L’Aquila, Italy
12 shared publications - Giulio D’emilia
Department of Industrial and Information Engineering and Economics, University of L’Aquila, 67100 L’Aquila, Italy
10 shared publications - Antonella Gaspari
Department of Mechanics, Mathematics and Management, Polytechnic of Bari, 70125 Bari, Italy
5 shared publications - Alessandro Schiavi
Division of Applied Metrology and Engineering, National Institute of Metrological Research (INRiM), Turin, Italy
3 shared publications - Andrea Prato
INRiM, Istituto Nazionale di Ricerca Metrologica, 10135 Torino, Italy
3 shared publications - Alessio Facello
Division of Applied Metrology and Engineering, National Institute of Metrological Research (INRiM), Turin, Italy
2 shared publications
Latest Publications
- Open Access
- 9 November 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (11) , 1302
Metrological Reliability and Long-Term Stability of Digital MEMS Accelerometers: Investigating Calibration Factor Drift, Output Data Rate (ODR) and Signal-to-Noise Ratio (SNR) Consistency Under Accelerated Thermal-Hygrometric Aging
This study investigates changes in three metrological attributes of eight nominally identical digital MEMS accelerometers from one production lot. After approximately six years of laboratory storage, six devices underwent three unpowered thermal-hygrometric stress protocols, while two devices provided a natural-aging baseline. Calibration factors were compared for one axis at 10 Hz, together with effective output data rate (ODR) and static signal-to-noise ratio (SNR). Arrhenius, Norris–Landzberg and Peck relationships were examined as conditional exposure-equivalence models rather than validated lifetime predictors. Two thermally cycled devices exhibited calibration-factor increases of 7.9% and 37.6%; the other four stressed devices remained compatible within the reported expanded uncertainties. ODR changes remained below 0.5% for all eight devices. The six stressed devices showed SNR decreases of 0.34–1.43 dB, averaging 0.89 dB, whereas the two baseline decreases were 0.34 and 0.20 dB. Stable ODR therefore did not guarantee stable calibration factor. The contribution is a paired assessment of these selected output attributes, not a complete characterization of the accelerometer or identification of the degrading subsystem. The limited sample size precludes population-level reliability estimates.
- 9 November 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (11) , 1302
Open AccessMetrological Reliability and Long-Term Stability of Digital MEMS Accelerometers: Investigating Calibration Factor Drift, Output Data Rate (ODR) and Signal-to-Noise Ratio (SNR) Consistency Under Accelerated Thermal-Hygrometric Aging
This study investigates changes in three metrological attributes of eight nominally identical digital MEMS accelerometers from one production lot. After approximately six years of laboratory storage, six devices underwent three unpowered thermal-hygrometric stress protocols, while two devices provided a natural-aging baseline. Calibration factors were compared for one axis at 10 Hz, together with effective output data rate (ODR) and static signal-to-noise ratio (SNR). Arrhenius, Norris–Landzberg and Peck relationships were examined as conditional exposure-equivalence models rather than validated lifetime predictors. Two thermally cycled devices exhibited calibration-factor increases of 7.9% and 37.6%; the other four stressed devices remained compatible within the reported expanded uncertainties. ODR changes remained below 0.5% for all eight devices. The six stressed devices showed SNR decreases of 0.34–1.43 dB, averaging 0.89 dB, whereas the two baseline decreases were 0.34 and 0.20 dB. Stable ODR therefore did not guarantee stable calibration factor. The contribution is a paired assessment of these selected output attributes, not a complete characterization of the accelerometer or identification of the degrading subsystem. The limited sample size precludes population-level reliability estimates.
- Open Access
- 29 September 2026
- Published by Elsevier in Measurement
- Vol. 292
Effective sampling-rate characterization of digital MEMS vibration sensing systems and implications for calibration
- 29 September 2026
- Published by Elsevier in Measurement
- Vol. 292
Open AccessEffective sampling-rate characterization of digital MEMS vibration sensing systems and implications for calibration
- Open Access
- 26 January 2026
- Published by MDPI AG in Instruments
- Vol. 10 (1) , 6
A Procedure for Performing Reproducibility Assessment of the Accuracy of Impact Area Classification for Structural Health Monitoring in Aerospace Structures
The principal objective of this work is to develop an optimized procedure that guarantees the reproducibility of results across different applications and laboratories, facilitating potential field applications of methodologies for Structural Health Monitoring in aerospace structures. The focus is to accurately detect and localize impact areas on planar structures using in situ transducers and Machine Learning (ML) techniques. The research concentrates on an aluminum plate where impacts are generated by metal spheres of different masses dropped from a fixed height. The resulting Lamb waves are detected by PZT sensors glued on the surface. Various data processing and feature extraction algorithms are implemented and compared to extract the differences in Time of Flight (ΔToF). The obtained features are used for training ML classification models. Then, the influence of various parameters in signal acquisition and data processing are assessed along with the reproducibility of the results. For this reason, an interlaboratory comparison is conducted in which the trained models are applied to data collected under varying conditions. The experimental results show that the most influencing factors for impact area classification are the algorithm for ΔToF estimation, the number of training points used in ML models, the type of classification model, the distribution of the impact points on the component, and their balance in the classification area. This evidence suggests approaches for reducing both issues, therefore improving the reproducibility of results.
- 26 January 2026
- Published by MDPI AG in Instruments
- Vol. 10 (1) , 6
Open AccessA Procedure for Performing Reproducibility Assessment of the Accuracy of Impact Area Classification for Structural Health Monitoring in Aerospace Structures
The principal objective of this work is to develop an optimized procedure that guarantees the reproducibility of results across different applications and laboratories, facilitating potential field applications of methodologies for Structural Health Monitoring in aerospace structures. The focus is to accurately detect and localize impact areas on planar structures using in situ transducers and Machine Learning (ML) techniques. The research concentrates on an aluminum plate where impacts are generated by metal spheres of different masses dropped from a fixed height. The resulting Lamb waves are detected by PZT sensors glued on the surface. Various data processing and feature extraction algorithms are implemented and compared to extract the differences in Time of Flight (ΔToF). The obtained features are used for training ML classification models. Then, the influence of various parameters in signal acquisition and data processing are assessed along with the reproducibility of the results. For this reason, an interlaboratory comparison is conducted in which the trained models are applied to data collected under varying conditions. The experimental results show that the most influencing factors for impact area classification are the algorithm for ΔToF estimation, the number of training points used in ML models, the type of classification model, the distribution of the impact points on the component, and their balance in the classification area. This evidence suggests approaches for reducing both issues, therefore improving the reproducibility of results.
- Open Access
A New and Smart Gas Meter with Blockchain Validation for Distributed Management of Energy Tokens
The design philosophy of a new smart gas meter is presented, based on an ultrasonic sensor employing LoRa and/or NB-IoT protocols and blockchain technologies to overcome the data integrity and security issues with a completely modular design. The architecture is organized into two separate blocks, the former for measurement and the latter for communication, and it presents original characteristics with respect to the state of the art. The accuracy of measured data is studied, paying attention to the fluid dynamic effects of the geometrical layout on the flow rate ultrasonic sensor and the environmental temperature and pressure for variable gas flow rate values. As for data security issues, the proposed solution is critically analyzed with reference to the data string organization and the procedure by which the data are stored and prepared for transmission into the blockchain. Finally, a local network of counters is designed and simulated in order to check the compliance of the provided hardware and software solutions with the predicted computational load.
Open AccessA New and Smart Gas Meter with Blockchain Validation for Distributed Management of Energy Tokens
The design philosophy of a new smart gas meter is presented, based on an ultrasonic sensor employing LoRa and/or NB-IoT protocols and blockchain technologies to overcome the data integrity and security issues with a completely modular design. The architecture is organized into two separate blocks, the former for measurement and the latter for communication, and it presents original characteristics with respect to the state of the art. The accuracy of measured data is studied, paying attention to the fluid dynamic effects of the geometrical layout on the flow rate ultrasonic sensor and the environmental temperature and pressure for variable gas flow rate values. As for data security issues, the proposed solution is critically analyzed with reference to the data string organization and the procedure by which the data are stored and prepared for transmission into the blockchain. Finally, a local network of counters is designed and simulated in order to check the compliance of the provided hardware and software solutions with the predicted computational load.
- Open Access
- 2 October 2025
- Published by MDPI AG in Preprints.org
A New and Smart Gas Meter with Blockchain Validation for Distributed Management of Energy Token
The design philosophy of a new smart gas meter is presented, based on an ultrasonic sensor, employing LoRa and/or NB-IoT protocols and block-chain technologies to overcome the data integrity and security issues with a completely modular design. The architecture is organized in two separate blocks, the former for measurement and the latter for communication, and it presents originality characteristics with respect to the state of the art. Accuracy of measured data is studied paying attention to fluid dynamic effects of the geometrical layout on the flow rate ultrasonic sensor and of the environmental temperature and pressure, for variable gas flowrate values. As for data security issues, the proposed solution is critically analyzed with reference to the data string organization and the procedure the data are stored and prepared for transmission into the blockchain. Finally, a local network of counters is designed and simulated in order to check the compliance of the provided hardware and software solutions with the predicted computational load.
- 2 October 2025
- Published by MDPI AG in Preprints.org
Open AccessA New and Smart Gas Meter with Blockchain Validation for Distributed Management of Energy Token
The design philosophy of a new smart gas meter is presented, based on an ultrasonic sensor, employing LoRa and/or NB-IoT protocols and block-chain technologies to overcome the data integrity and security issues with a completely modular design. The architecture is organized in two separate blocks, the former for measurement and the latter for communication, and it presents originality characteristics with respect to the state of the art. Accuracy of measured data is studied paying attention to fluid dynamic effects of the geometrical layout on the flow rate ultrasonic sensor and of the environmental temperature and pressure, for variable gas flowrate values. As for data security issues, the proposed solution is critically analyzed with reference to the data string organization and the procedure the data are stored and prepared for transmission into the blockchain. Finally, a local network of counters is designed and simulated in order to check the compliance of the provided hardware and software solutions with the predicted computational load.
- Open Access
- 1 July 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3063 (1)
Optical analysis of composite materials: metrological issues
In this paper, a procedure to improve the winding angle measurement of a filament winded composite component is proposed. The procedure is based on the use of a polarized camera that can acquire information on the direction of the light. This vision system has been proven to be suitable for the analysis of a carbon fibre surface due to the physical property of this material. It reflects light with a polarization angle equal to the orientation of the fibres. A statistical analysis of the angle of linear polarization (AoLP) for each pixel within the examined regions enables the evaluation of the winding angle. For improving this measurement, some geometrical and methodological aspects are examined in detail. A procedure for identifying a region of interest (RoI) in surface acquisition is proposed, and the impact of integrating multiple images of the same area is assessed. The result is a reduction in the variability of the measured distribution of the fiber angles.
- 1 July 2025
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3063 (1)
Open AccessOptical analysis of composite materials: metrological issues
In this paper, a procedure to improve the winding angle measurement of a filament winded composite component is proposed. The procedure is based on the use of a polarized camera that can acquire information on the direction of the light. This vision system has been proven to be suitable for the analysis of a carbon fibre surface due to the physical property of this material. It reflects light with a polarization angle equal to the orientation of the fibres. A statistical analysis of the angle of linear polarization (AoLP) for each pixel within the examined regions enables the evaluation of the winding angle. For improving this measurement, some geometrical and methodological aspects are examined in detail. A procedure for identifying a region of interest (RoI) in surface acquisition is proposed, and the impact of integrating multiple images of the same area is assessed. The result is a reduction in the variability of the measured distribution of the fiber angles.
- Open Access
- 10 June 2025
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 14 (2) , 1-6
Statistical analysis of the angle of linear polarization for the winding angle measurement in carbon fibre components
In this work, the problem of determining the winding angle in a cylindrical carbon fiber piece, obtained through a filament winding process, is investigated. A polarization camera is used for the measurement, and the winding angle is determined by statistically analyzing the angle of linear polarization in each pixel of the region under study. The main influence parameters are considered, like non-planarity and superficial state of the piece, with the aim of reducing the measurement uncertainty. For this purpose, two different types of data processing approaches are tested and compared.
- 10 June 2025
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 14 (2) , 1-6
Open AccessStatistical analysis of the angle of linear polarization for the winding angle measurement in carbon fibre components
In this work, the problem of determining the winding angle in a cylindrical carbon fiber piece, obtained through a filament winding process, is investigated. A polarization camera is used for the measurement, and the winding angle is determined by statistically analyzing the angle of linear polarization in each pixel of the region under study. The main influence parameters are considered, like non-planarity and superficial state of the piece, with the aim of reducing the measurement uncertainty. For this purpose, two different types of data processing approaches are tested and compared.
- Open Access
Dynamic Multi-Axis Calibration of MEMS Accelerometers for Sensitivity and Linearity Assessment
A set of commercial triaxial micro-electromechanical systems (MEMS) accelerometers was calibrated using a custom-designed test bench featuring a rotating table. The calibration setup enabled simultaneous assessment of all accelerometer measurement components, generating precise reference accelerations within a frequency range of 0 to 8 Hz. A working model of the calibration setup and procedure was described to provide a complete uncertainty budget for both the reference and sensor accelerations. Through experimental uncertainty assessment of all the accelerometers, linearity and sensitivity were evaluated at different sensor levels. These parameters were determined by considering a single value for each accelerometer and detailing the analysis for each axis. Data processing revealed the achievable level of uncertainty and how it was influenced by the evaluation method employed for analyzing the calibration data.
Open AccessDynamic Multi-Axis Calibration of MEMS Accelerometers for Sensitivity and Linearity Assessment
A set of commercial triaxial micro-electromechanical systems (MEMS) accelerometers was calibrated using a custom-designed test bench featuring a rotating table. The calibration setup enabled simultaneous assessment of all accelerometer measurement components, generating precise reference accelerations within a frequency range of 0 to 8 Hz. A working model of the calibration setup and procedure was described to provide a complete uncertainty budget for both the reference and sensor accelerations. Through experimental uncertainty assessment of all the accelerometers, linearity and sensitivity were evaluated at different sensor levels. These parameters were determined by considering a single value for each accelerometer and detailing the analysis for each axis. Data processing revealed the achievable level of uncertainty and how it was influenced by the evaluation method employed for analyzing the calibration data.
- Open Access
- 24 January 2025
- Published by MDPI AG in Preprints.org
Dynamic Multi-Axis Calibration of MEMS Accelerometers for Sensitivity and Linearity Assessment
A set of triaxial MEMS (Micro-Electro-Mechanical Systems) accelerometer, of commercial type, has been calibrated on a test bench, which is based on a rotating table. The bench has been designed for this specific purpose and it allows to calibrate contemporaneously all accelerometer measuring components, by realizing accurate reference accelerations in the frequency range 0 to 8 Hz. A working model of the calibration set-up and procedure is described to realize a complete and detailed uncertainty budget of the reference and of the sensor accelerations. Experimental uncertainty assessment of all the accelerometers has been carried out, allowing to obtain all the linearity and sensitivity data, accelerometer by accelerometer, axis by axis. Data processing has been carried out and interesting information is get about the level of uncertainty which is achievable, depending on the way the calibration data are evaluated, taking into account or not differences of sensitivity data for each other accelerometer and/or considering differences among measuring components of a single accelerometer.
- 24 January 2025
- Published by MDPI AG in Preprints.org
Open AccessDynamic Multi-Axis Calibration of MEMS Accelerometers for Sensitivity and Linearity Assessment
A set of triaxial MEMS (Micro-Electro-Mechanical Systems) accelerometer, of commercial type, has been calibrated on a test bench, which is based on a rotating table. The bench has been designed for this specific purpose and it allows to calibrate contemporaneously all accelerometer measuring components, by realizing accurate reference accelerations in the frequency range 0 to 8 Hz. A working model of the calibration set-up and procedure is described to realize a complete and detailed uncertainty budget of the reference and of the sensor accelerations. Experimental uncertainty assessment of all the accelerometers has been carried out, allowing to obtain all the linearity and sensitivity data, accelerometer by accelerometer, axis by axis. Data processing has been carried out and interesting information is get about the level of uncertainty which is achievable, depending on the way the calibration data are evaluated, taking into account or not differences of sensitivity data for each other accelerometer and/or considering differences among measuring components of a single accelerometer.
- Open Access
Using Light Polarization to Identify Fiber Orientation in Carbon Fiber Components: Metrological Analysis
In this work, a method for measuring tow angles in carbon fiber components, based on the use of a polarized camera, is analyzed from a metrological point of view. Carbon fibers alter the direction of the reflected light’s electrical field, so that in each point of the surface of a composite piece, the angle of polarization of reflected light matches the fiber orientation. A statistical analysis of the angle of linear polarization (AoLP) in each pixel of each examined area allows to evaluate the average winding angle. An evaluation of the measurement uncertainty of the method on a cylinder obtained by a filament winding process is carried out, and the result appears adequate for the study of the distribution of angles along the surface of the piece, in order to optimize the process.
Open AccessUsing Light Polarization to Identify Fiber Orientation in Carbon Fiber Components: Metrological Analysis
In this work, a method for measuring tow angles in carbon fiber components, based on the use of a polarized camera, is analyzed from a metrological point of view. Carbon fibers alter the direction of the reflected light’s electrical field, so that in each point of the surface of a composite piece, the angle of polarization of reflected light matches the fiber orientation. A statistical analysis of the angle of linear polarization (AoLP) in each pixel of each examined area allows to evaluate the average winding angle. An evaluation of the measurement uncertainty of the method on a cylinder obtained by a filament winding process is carried out, and the result appears adequate for the study of the distribution of angles along the surface of the piece, in order to optimize the process.