Viswateja Kasarabada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Viswateja Kasarabada has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Blanca H. Lapizco-Encinas
Microscale Bioseparations Laboratory and Biomedical Engineering Department Rochester Institute of Technology Rochester New York USA
3 shared publications - Alaleh Vaghef-Koodehi
Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, New York 14623, United States
2 shared publications Gabriela Martinez-Martinez
Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, New York 14623, United States
1 shared publication- Julie. A. Thomas
Thomas H. Gosnell School of Life Sciences, Rochester Institute of Technology, Rochester, NY 14623, USA
1 shared publication Nuzhet Nihaar Nasir Ahamed
Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, 160 Lomb Memorial Drive, Rochester, New York 14623, United States
1 shared publication- Olivia D. Ernst
Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, United States of America
1 shared publication
Latest Publications
- Open Access
- 10 March 2026
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 151 (9) , 2682-2693
Electrokinetic separation of bacteriophage ϕKZ from bacterial cells
Binding-induced zeta potential shifts facilitated the electrokinetic streaming separations of bacteriophage ϕKZ from Escherichia coli at 194.3 V/cm and 430.4 V/cm. A streaming–trapping approach selectively immobilized bacterial cells at 580.6 V/cm.
- 10 March 2026
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 151 (9) , 2682-2693
Open AccessElectrokinetic separation of bacteriophage ϕKZ from bacterial cells
Binding-induced zeta potential shifts facilitated the electrokinetic streaming separations of bacteriophage ϕKZ from Escherichia coli at 194.3 V/cm and 430.4 V/cm. A streaming–trapping approach selectively immobilized bacterial cells at 580.6 V/cm.
- 18 September 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (39) , 15711-15719
Separating the Living from the Dead: An Electrophoretic Approach
Cell viability studies are essential in numerous applications, including drug development, clinical analysis, bioanalytical assessments, food safety, and environmental monitoring. Microfluidic electrokinetic (EK) devices have been proven to be effective platforms to discriminate microorganisms by their viability status. Two decades ago, live and dead Escherichia coli (E. coli) cells were trapped at distinct locations in an insulator-based EK (iEK) device with cylindrical insulating posts. At that time, the discrimination between live and dead cells was attributed to dielectrophoretic effects. This study presents the continuous separation between the live and dead E. coli cells, which was achieved primarily by combining linear and nonlinear electrophoretic effects in an iEK device. First, live and dead E. coli cells were characterized in terms of their electrophoretic migration, and then the properties of both live and dead E. coli cells were input into a mathematical model built using COMSOL Multiphysics software to identify appropriate voltages for performing an iEK separation in a T-cross iEK channel. Subsequently, live and dead cells were successfully separated experimentally in the form of an electropherogram, achieving a separation resolution of 1.87. This study demonstrated that linear and nonlinear electrophoresis phenomena are responsible for the discrimination between live and dead cells under DC electric fields in iEK devices. Continuous electrophoretic assessments, such as the one presented here, can be used to discriminate between distinct types of microorganisms including live and dead cell assessments.
- 18 September 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (39) , 15711-15719
Separating the Living from the Dead: An Electrophoretic Approach
Cell viability studies are essential in numerous applications, including drug development, clinical analysis, bioanalytical assessments, food safety, and environmental monitoring. Microfluidic electrokinetic (EK) devices have been proven to be effective platforms to discriminate microorganisms by their viability status. Two decades ago, live and dead Escherichia coli (E. coli) cells were trapped at distinct locations in an insulator-based EK (iEK) device with cylindrical insulating posts. At that time, the discrimination between live and dead cells was attributed to dielectrophoretic effects. This study presents the continuous separation between the live and dead E. coli cells, which was achieved primarily by combining linear and nonlinear electrophoretic effects in an iEK device. First, live and dead E. coli cells were characterized in terms of their electrophoretic migration, and then the properties of both live and dead E. coli cells were input into a mathematical model built using COMSOL Multiphysics software to identify appropriate voltages for performing an iEK separation in a T-cross iEK channel. Subsequently, live and dead cells were successfully separated experimentally in the form of an electropherogram, achieving a separation resolution of 1.87. This study demonstrated that linear and nonlinear electrophoresis phenomena are responsible for the discrimination between live and dead cells under DC electric fields in iEK devices. Continuous electrophoretic assessments, such as the one presented here, can be used to discriminate between distinct types of microorganisms including live and dead cell assessments.
- 26 January 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1717, 464685
Effect of cell shape on nonlinear electrophoresis migration
- 26 January 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1717, 464685
Effect of cell shape on nonlinear electrophoresis migration