Miroslav Jicha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Miroslav Jicha has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Ondrej Hajek
Energy Institute, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic
3 shared publications - Adrian Kummerländer
Karlsruhe Institute of Technology, Kaiserstrasse 12, Karlsruhe, 76131, Germany
2 shared publications - Frantisek Lizal
Brno University of Technology, Technicka 2896, Brno, 616 69, Czech Republic
2 shared publications - František Prinz
Brno University of Technology, Technicka 2896, Brno, 616 69, Czech Republic
2 shared publications - Jakub Elcner
Brno University of Technology, Technicka 2896, Brno, 616 69, Czech Republic
2 shared publications - Jan Pokorný
Brno University of Technology, Faculty of Mechanical Engineering, Energy Institute, Technicka 2896/2, Brno, Czech Republic
2 shared publications
Latest Publications
- Open Access
- 9 September 2026
- Published by Elsevier in SSRN Electronic Journal
Triply periodic minimal surface packings for rotating packed beds: pressure drop, flooding and liquid distribution
Rotating packed beds (RPBs) intensify gas–liquid contact, but their compact design requires uniformly distributed liquid through the packing. Additive manufacturing allows packings based on triply periodic minimal surfaces (TPMS), whose porosity and specific surface area (SSA) can be set independently. Sixteen 3D-printed gyroid, diamond and split-P TPMS packings, covering 64–83% overall porosity and 719–1399 m²/m³ SSA and including two radial gradient designs, were tested in a transparent RPB against a commercial metal foam. Wet pressure drop and flooding were measured at 63 operating points per packing (200–1800 rpm, 60–150 kg/h liquid, 20–80 m³/h gas) and the axial droplet distribution was measured by phase Doppler anemometry. Pressure drop follows the free cross-section and rises by up to 19% from 83% to 64% porosity and by 16% over the SSA range. Both radial gradient designs, reported to favour mass transfer, add no high-speed pressure-drop penalty. Above the flooding region the three topologies agree to within about 10%, while in the flooding region the split-P floods first. An empirical model in rotational speed, gas flow rate, SSA and porosity describes all sixteen packings to a pooled mean absolute deviation of 3.5%. Most gyroids centre the liquid within 3.5 mm of the symmetry plane, the diamond displaces it by more than 7.5 mm, and the split-P and the metal foam stay centred. The structure sets the sign of the displacement, while the operating point adds a common shift caused by the gas flow in the cavity.
- 9 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessTriply periodic minimal surface packings for rotating packed beds: pressure drop, flooding and liquid distribution
Rotating packed beds (RPBs) intensify gas–liquid contact, but their compact design requires uniformly distributed liquid through the packing. Additive manufacturing allows packings based on triply periodic minimal surfaces (TPMS), whose porosity and specific surface area (SSA) can be set independently. Sixteen 3D-printed gyroid, diamond and split-P TPMS packings, covering 64–83% overall porosity and 719–1399 m²/m³ SSA and including two radial gradient designs, were tested in a transparent RPB against a commercial metal foam. Wet pressure drop and flooding were measured at 63 operating points per packing (200–1800 rpm, 60–150 kg/h liquid, 20–80 m³/h gas) and the axial droplet distribution was measured by phase Doppler anemometry. Pressure drop follows the free cross-section and rises by up to 19% from 83% to 64% porosity and by 16% over the SSA range. Both radial gradient designs, reported to favour mass transfer, add no high-speed pressure-drop penalty. Above the flooding region the three topologies agree to within about 10%, while in the flooding region the split-P floods first. An empirical model in rotational speed, gas flow rate, SSA and porosity describes all sixteen packings to a pooled mean absolute deviation of 3.5%. Most gyroids centre the liquid within 3.5 mm of the symmetry plane, the diamond displaces it by more than 7.5 mm, and the split-P and the metal foam stay centred. The structure sets the sign of the displacement, while the operating point adds a common shift caused by the gas flow in the cavity.
- Open Access
- 12 June 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 194, 110473
Transport and deposition of inhaled fibers in a realistic female airway model: A combined experimental and numerical study
- 12 June 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 194, 110473
Open AccessTransport and deposition of inhaled fibers in a realistic female airway model: A combined experimental and numerical study
- 10 October 2024
- Published by Elsevier in Separation and Purification Technology
- Vol. 357
Analysis of droplet motion in cavity zone of rotating packed bed
- 10 October 2024
- Published by Elsevier in Separation and Purification Technology
- Vol. 357
Analysis of droplet motion in cavity zone of rotating packed bed
- 15 January 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 170, 107994
Comprehensive experimental and numerical validation of Lattice Boltzmann fluid flow and particle simulations in a child respiratory tract
- 15 January 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 170, 107994
Comprehensive experimental and numerical validation of Lattice Boltzmann fluid flow and particle simulations in a child respiratory tract
- Open Access
- 20 February 2021
- Published by JVE International Ltd. in Journal of Measurements in Engineering
- Vol. 9 (1) , 36-47
Case study comparing Fiala-based thermophysiological model and PHS Index with experimental data to predict heat strain in normal and protective clothing
The use of protective clothing under extreme conditions leads to heat stress with undesired consequences on human physiology. As a prevention measure, thermal indices and thermophysiological models have been developed. Based on these models and indices, it is possible to estimate the time limits for staying under risky conditions, e.g., by the predicted rectal temperature whose value is one of the most important parameters used for assessing the heat stress. This article is focused on the comparison of rectal and mean skin temperature prediction realized by the Fiala-based thermophysiological model (FMTK) and Predicted heat strain (PHS) index with results from the real experiment for normal and protective clothing. Three types of ensembles were tested and simulated as follows: Klimatex underwear, air-permeable military NBC suit M2000 (FOP), and impermeable chemical protective clothing Tychem-F. The real experiments of thermal strain were performed with one male participant (80 kg, 1.75 m) walking on the treadmill located in the climate chamber. The temperature range for neutral and hot tests was set from 25 °C to 40 °C. The rectal temperature, skin temperatures, and heart rate were measured. The results showed that PHS index is well usable for normal clothing (Klimatex underwear) and air-permeable protective clothing (FOP) under various ambient temperatures, and it is able to give results similar to FMTK model and experiment, the mean absolute error MAE for rectal temperature prediction was for all ambient temperatures lower than 0.5 °C. FMTK model demonstrated good predictability for impermeable protective clothing Tychem-F, the maximum value of MAE 0.69 °C. Whereas PHS index showed several times larger error, the maximum value higher than 1.8 °C, in the prediction for this type of clothing. The performed simulations showed that the accuracy of the prediction by the PHS index is not so strongly dependent on the value of the overall clothing resistance, but it depends on the value of the moisture permeability index (permeable vs impermeable clothing) which is connected with the water vapor partial pressure under the clothing.
- 20 February 2021
- Published by JVE International Ltd. in Journal of Measurements in Engineering
- Vol. 9 (1) , 36-47
Open AccessCase study comparing Fiala-based thermophysiological model and PHS Index with experimental data to predict heat strain in normal and protective clothing
The use of protective clothing under extreme conditions leads to heat stress with undesired consequences on human physiology. As a prevention measure, thermal indices and thermophysiological models have been developed. Based on these models and indices, it is possible to estimate the time limits for staying under risky conditions, e.g., by the predicted rectal temperature whose value is one of the most important parameters used for assessing the heat stress. This article is focused on the comparison of rectal and mean skin temperature prediction realized by the Fiala-based thermophysiological model (FMTK) and Predicted heat strain (PHS) index with results from the real experiment for normal and protective clothing. Three types of ensembles were tested and simulated as follows: Klimatex underwear, air-permeable military NBC suit M2000 (FOP), and impermeable chemical protective clothing Tychem-F. The real experiments of thermal strain were performed with one male participant (80 kg, 1.75 m) walking on the treadmill located in the climate chamber. The temperature range for neutral and hot tests was set from 25 °C to 40 °C. The rectal temperature, skin temperatures, and heart rate were measured. The results showed that PHS index is well usable for normal clothing (Klimatex underwear) and air-permeable protective clothing (FOP) under various ambient temperatures, and it is able to give results similar to FMTK model and experiment, the mean absolute error MAE for rectal temperature prediction was for all ambient temperatures lower than 0.5 °C. FMTK model demonstrated good predictability for impermeable protective clothing Tychem-F, the maximum value of MAE 0.69 °C. Whereas PHS index showed several times larger error, the maximum value higher than 1.8 °C, in the prediction for this type of clothing. The performed simulations showed that the accuracy of the prediction by the PHS index is not so strongly dependent on the value of the overall clothing resistance, but it depends on the value of the moisture permeability index (permeable vs impermeable clothing) which is connected with the water vapor partial pressure under the clothing.