Lei Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lei Chang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Shijie Zhu
4 shared publicationsLiguo Wang
3 shared publications- Shaokang Guan
School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, 450001, China
3 shared publications Ding He
School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, China
1 shared publicationHe Zhang
School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, China
1 shared publicationJiayin Zhao
School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, China
1 shared publication
Latest Publications
- 29 September 2020
- Published by Springer Nature in Frontiers of Materials Science
- Vol. 14 (4) , 413-425
Micro-patterned hydroxyapatite/silk fibroin coatings on Mg-Zn-Y-Nd-Zr alloys for better corrosion resistance and cell behavior guidance
- 29 September 2020
- Published by Springer Nature in Frontiers of Materials Science
- Vol. 14 (4) , 413-425
Micro-patterned hydroxyapatite/silk fibroin coatings on Mg-Zn-Y-Nd-Zr alloys for better corrosion resistance and cell behavior guidance
- 30 March 2018
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 29 (4) , 44
Investigation on the in vitro cytocompatibility of Mg-Zn-Y-Nd-Zr alloys as degradable orthopaedic implant materials
Mg-Zn-Y-Nd-Zr alloy has been developed as a new type of biodegradable orthopaedic implant material by the authors’ research group with its excellent mechanical properties and controllable degradation rate. In this study, the cytocompatibility of Mg-Zn-Y-Nd-Zr alloy was systematically evaluated through in vitro cell culture method. MTT assay was applied to evaluate the cytotoxicity of Mg-Zn-Y-Nd-Zr alloy and no toxic effect was observed on L929 and MC3T3-E1 cells followed the protocol of ISO 10993 standard. Considering the potential ion accumulation in the bony environment, this study further investigated the cytotoxic effect of accumulated metallic ions during the alloy degradation by extending the extract preparation time. When the extract preparation time was prolonged to 1440 h, the accumulated metallic ions leaded to severe cell apoptosis, of which the combined ion concentration was determined as 39.5–65.8 µM of Mg2+, 3.5–5.9 µM of Zn2+, 0.44–0.74 µM of Y3+, 0.3–0.52 µM of Nd3+ and 0.11–0.18 µM of Zr4+ for L929, and 65.8–92.2 µM of Mg2+, 5.9–8.3 µM of Zn2+, 0.74–1.04 µM of Y3+, 0.52–0.73 µM of Nd3+ and 0.18–0.25 µM of Zr4+ for MC3T3-E1 cells. Besides the cell viability assessment, high expression of ALP activity and calcified nodules implied that metal elements in Mg-Zn-Y-Nd-Zr alloys can promote the osteogenic differentiation. Hence, excellent cytocompatibility has equipped Mg-Zn-Y-Nd-Zr alloy as a promising candidate for orthopaedic implant application, which can remarkably guide the magnesium-based alloy design and provide scientific evidence for clinical practice in future.
- 30 March 2018
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 29 (4) , 44
Investigation on the in vitro cytocompatibility of Mg-Zn-Y-Nd-Zr alloys as degradable orthopaedic implant materials
Mg-Zn-Y-Nd-Zr alloy has been developed as a new type of biodegradable orthopaedic implant material by the authors’ research group with its excellent mechanical properties and controllable degradation rate. In this study, the cytocompatibility of Mg-Zn-Y-Nd-Zr alloy was systematically evaluated through in vitro cell culture method. MTT assay was applied to evaluate the cytotoxicity of Mg-Zn-Y-Nd-Zr alloy and no toxic effect was observed on L929 and MC3T3-E1 cells followed the protocol of ISO 10993 standard. Considering the potential ion accumulation in the bony environment, this study further investigated the cytotoxic effect of accumulated metallic ions during the alloy degradation by extending the extract preparation time. When the extract preparation time was prolonged to 1440 h, the accumulated metallic ions leaded to severe cell apoptosis, of which the combined ion concentration was determined as 39.5–65.8 µM of Mg2+, 3.5–5.9 µM of Zn2+, 0.44–0.74 µM of Y3+, 0.3–0.52 µM of Nd3+ and 0.11–0.18 µM of Zr4+ for L929, and 65.8–92.2 µM of Mg2+, 5.9–8.3 µM of Zn2+, 0.74–1.04 µM of Y3+, 0.52–0.73 µM of Nd3+ and 0.18–0.25 µM of Zr4+ for MC3T3-E1 cells. Besides the cell viability assessment, high expression of ALP activity and calcified nodules implied that metal elements in Mg-Zn-Y-Nd-Zr alloys can promote the osteogenic differentiation. Hence, excellent cytocompatibility has equipped Mg-Zn-Y-Nd-Zr alloy as a promising candidate for orthopaedic implant application, which can remarkably guide the magnesium-based alloy design and provide scientific evidence for clinical practice in future.
- 14 August 2017
- Published by Wiley in Surface and Interface Analysis
- Vol. 49 (11) , 1115-1123
Characterization and cytocompatibility of polydopamine on MAO‐HA coating supported on Mg‐Zn‐Ca alloy
Magnesium has been suggested as a potential biodegradable metal for the usage as orthopaedic implants. However, high degradation rate in physiological environment remains the biggest challenge, impeding wide clinical application of magnesium‐based biomaterials. In order to reduce its degradation rate and improve the biocompatibility, micro‐arc oxidation coating doped with HA particles (MAO‐HA) was applied as the inner coating, and polydopamine (PDA) film was synthesized by dopamine self‐polymerization as the outer coating. The microstructure evolution of the coating was characterized using scanning electron microscopy (SEM), atomic force microscope (AFM), X‐ray diffraction analyses (XRD), Fourier transform infrared spectroscopy (FT‐IR), and X‐ray photoelectron spectroscopy (XPS). The results showed that PDA film had covered the entire surface of MAO‐HA coating and the pore size of MAO‐HA coating decreased. The root mean square (RMS) roughness of PDA/MAO‐HA coatings was approximately 106.46 nm, which was closer to the optimum surface roughness for cellular attachment as compared with MAO‐HA coatings. Contact angle measurement indicated that the surface wettability had been transformed from hydrophobic to hydrophilic due to the introduction of PDA. The PDA/MAO‐HA coatings exhibited better corrosion resistance in vitro, with the self‐corrosion potential increasing by 150 mV and the corrosion current density decreasing from 2.09 × 10 −5 A/cm 2 to 1.46 × 10 −6 A/cm 2 . In hydrogen evolution tests, the corrosion rates of the samples coated with PDA/MAO‐HA and MAO‐HA were 4.40 and 5.95 mm/y, respectively. MTS assay test and cell‐surface interactions experiment demonstrated that PDA/MAO‐HA coatings exhibited good cellular compatibility and could promote the adhesion and proliferation of MC3T3‐E1 cells.
- 14 August 2017
- Published by Wiley in Surface and Interface Analysis
- Vol. 49 (11) , 1115-1123
Characterization and cytocompatibility of polydopamine on MAO‐HA coating supported on Mg‐Zn‐Ca alloy
Magnesium has been suggested as a potential biodegradable metal for the usage as orthopaedic implants. However, high degradation rate in physiological environment remains the biggest challenge, impeding wide clinical application of magnesium‐based biomaterials. In order to reduce its degradation rate and improve the biocompatibility, micro‐arc oxidation coating doped with HA particles (MAO‐HA) was applied as the inner coating, and polydopamine (PDA) film was synthesized by dopamine self‐polymerization as the outer coating. The microstructure evolution of the coating was characterized using scanning electron microscopy (SEM), atomic force microscope (AFM), X‐ray diffraction analyses (XRD), Fourier transform infrared spectroscopy (FT‐IR), and X‐ray photoelectron spectroscopy (XPS). The results showed that PDA film had covered the entire surface of MAO‐HA coating and the pore size of MAO‐HA coating decreased. The root mean square (RMS) roughness of PDA/MAO‐HA coatings was approximately 106.46 nm, which was closer to the optimum surface roughness for cellular attachment as compared with MAO‐HA coatings. Contact angle measurement indicated that the surface wettability had been transformed from hydrophobic to hydrophilic due to the introduction of PDA. The PDA/MAO‐HA coatings exhibited better corrosion resistance in vitro, with the self‐corrosion potential increasing by 150 mV and the corrosion current density decreasing from 2.09 × 10 −5 A/cm 2 to 1.46 × 10 −6 A/cm 2 . In hydrogen evolution tests, the corrosion rates of the samples coated with PDA/MAO‐HA and MAO‐HA were 4.40 and 5.95 mm/y, respectively. MTS assay test and cell‐surface interactions experiment demonstrated that PDA/MAO‐HA coatings exhibited good cellular compatibility and could promote the adhesion and proliferation of MC3T3‐E1 cells.