Johannes Klueppel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Johannes Klueppel has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Laura Maria Comella
Institute of Energy Efficient Mobility, Karlsruhe University of Applied Sciences, Karlsruhe, 76133, Germany
8 shared publications - Christiane Werner
Ecosystem Physiology, Faculty of Environment and Natural Resources, University of Freiburg, Freiburg, Germany
2 shared publications Samaneh Baghbani
Department of Microsystems Engineering, Albert-Ludwigs-Universität Freiburg, Georges-Koehler-Allee 102, 79110 Freiburg, Germany
2 shared publications- Stefan Johann Rupitsch
Laboratory for Electrical Instrumentation and Embedded Systems, Department of Microsystems Engineering, University of Freiburg, 79110 Freiburg, Germany
2 shared publications - Abhishek Sharma
University of Freiburg Georges-Köhler-Allee 105
1 shared publication Ahmed Hellmy Zagho
University of Freiburg
1 shared publication
Latest Publications
- Open Access
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (17) , 25905-25915
Environmental Effects on Chip-Scale Multispectral Light Sensor
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (17) , 25905-25915
Open AccessEnvironmental Effects on Chip-Scale Multispectral Light Sensor
- Open Access
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 24225-24238
Development of a Low-Cost, Autonomous Pulse Amplitude Modulated (PAM) Chlorophyll Fluorometer for In Situ Monitoring of Photosystem II Efficiency
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 24225-24238
Open AccessDevelopment of a Low-Cost, Autonomous Pulse Amplitude Modulated (PAM) Chlorophyll Fluorometer for In Situ Monitoring of Photosystem II Efficiency
- Open Access
- 25 June 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (26) , 39114-39123
Design of a Chlorophyll Fluorescence Sensor Head for Continuous On-Leaf Measurements
Continuous monitoring of physiological activity is increasingly important for environmental observation systems that track ecosystem responses to drought stressors. Chlorophyll fluorescence (ChlF) is a sensitive, early indicator of drought-induced stress in trees that is directly measured on leaves and needles. However, existing autonomous ChlF systems are typically bulky and disturb natural leaf movement or provide insufficient excitation intensity for reliable measurements. Here, we present a leaf-wearable sensor head specifically engineered for long-term, autonomous environmental monitoring in forests. The design integrates a high-intensity excitation interface based on a blue LED, delivering up to 9000 μmol m–2 s–1. The operation of the LED directly on the leaf enables energy-efficient excitation. To facilitate energy-aware design of field sensing systems, we introduce the metric photon density efficacy (μmol m–2 s–1 mW–1) for quantifying excitation efficiency in power-constrained fluorescence sensors. To ensure stable measurements under environmental forcing, the sensor head incorporates a 4.1 g lightweight Y-shaped magnetic attachment structure with a soft silicone interface, designed to maintain constant sensor–leaf geometry while allowing natural leaf motion. Mechanical characterization demonstrated a mean pull-off force of 3.41 N, while field tests confirmed reliable sensor operation under wind speeds up to 21.5 m s–1. The presented design enables the nonintrusive integration of optical sensors directly on leaves and needles for extended monitoring periods. This work establishes a new hardware approach for distributed leaf-level sensing within environmental monitoring networks, enabling high-resolution observation of vegetation physiological dynamics across spatial and temporal scales.
- 25 June 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (26) , 39114-39123
Open AccessDesign of a Chlorophyll Fluorescence Sensor Head for Continuous On-Leaf Measurements
Continuous monitoring of physiological activity is increasingly important for environmental observation systems that track ecosystem responses to drought stressors. Chlorophyll fluorescence (ChlF) is a sensitive, early indicator of drought-induced stress in trees that is directly measured on leaves and needles. However, existing autonomous ChlF systems are typically bulky and disturb natural leaf movement or provide insufficient excitation intensity for reliable measurements. Here, we present a leaf-wearable sensor head specifically engineered for long-term, autonomous environmental monitoring in forests. The design integrates a high-intensity excitation interface based on a blue LED, delivering up to 9000 μmol m–2 s–1. The operation of the LED directly on the leaf enables energy-efficient excitation. To facilitate energy-aware design of field sensing systems, we introduce the metric photon density efficacy (μmol m–2 s–1 mW–1) for quantifying excitation efficiency in power-constrained fluorescence sensors. To ensure stable measurements under environmental forcing, the sensor head incorporates a 4.1 g lightweight Y-shaped magnetic attachment structure with a soft silicone interface, designed to maintain constant sensor–leaf geometry while allowing natural leaf motion. Mechanical characterization demonstrated a mean pull-off force of 3.41 N, while field tests confirmed reliable sensor operation under wind speeds up to 21.5 m s–1. The presented design enables the nonintrusive integration of optical sensors directly on leaves and needles for extended monitoring periods. This work establishes a new hardware approach for distributed leaf-level sensing within environmental monitoring networks, enabling high-resolution observation of vegetation physiological dynamics across spatial and temporal scales.
- Open Access
- 20 April 2026
- Published by Elsevier in SSRN Electronic Journal
Design of a Chlorophyll Fluorescence Sensor Head for Continuous On-Leaf Measurements
Continuous monitoring of physiological activity is increasingly important for environmental observation systems that track ecosystem responses to drought stressors. Chlorophyll fluorescence (ChlF) is a sensitive, early indicator of drought-induced stress in trees that is directly measured on leaves and needles. However, existing autonomous ChlF systems are typically bulky and disturb natural leaf movement or provide insufficient excitation intensity for reliable measurements. Here, we present a leaf-wearable sensor head specifically engineered for long-term, autonomous environmental monitoring in forests. The design integrates a high-intensity excitation interface based on a blue LED, delivering up to 9000 µmol m-2 s-1. The operation of the LED directly on the leaf enables energy-efficient excitation. To facilitate energy-aware design of field sensing systems, we introduce the metric photon density efficacy (µmol m-2 s-1 mW-1) for quantifying excitation efficiency in powerconstrained fluorescence sensors. To ensure stable measurements under environmental forcing, the sensor head incorporates a 4.1 g lightweight Y-shaped magnetic attachment structure with a soft silicone interface, designed to maintain constant sensor-leaf geometry while allowing natural leaf motion. Mechanical characterization demonstrated a mean pull-off force of 3.41 N, while field tests confirmed reliable sensor operation under wind speeds up to 21.5 m s-1. The presented design enables the non-intrusive integration of optical sensors directly on leaves and needles for extended monitoring periods. This work establishes a new hardware approach for distributed leaf-level sensing within environmental monitoring networks, enabling high-resolution observation of vegetation physiological dynamics across spatial and temporal scales.
- 20 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDesign of a Chlorophyll Fluorescence Sensor Head for Continuous On-Leaf Measurements
Continuous monitoring of physiological activity is increasingly important for environmental observation systems that track ecosystem responses to drought stressors. Chlorophyll fluorescence (ChlF) is a sensitive, early indicator of drought-induced stress in trees that is directly measured on leaves and needles. However, existing autonomous ChlF systems are typically bulky and disturb natural leaf movement or provide insufficient excitation intensity for reliable measurements. Here, we present a leaf-wearable sensor head specifically engineered for long-term, autonomous environmental monitoring in forests. The design integrates a high-intensity excitation interface based on a blue LED, delivering up to 9000 µmol m-2 s-1. The operation of the LED directly on the leaf enables energy-efficient excitation. To facilitate energy-aware design of field sensing systems, we introduce the metric photon density efficacy (µmol m-2 s-1 mW-1) for quantifying excitation efficiency in powerconstrained fluorescence sensors. To ensure stable measurements under environmental forcing, the sensor head incorporates a 4.1 g lightweight Y-shaped magnetic attachment structure with a soft silicone interface, designed to maintain constant sensor-leaf geometry while allowing natural leaf motion. Mechanical characterization demonstrated a mean pull-off force of 3.41 N, while field tests confirmed reliable sensor operation under wind speeds up to 21.5 m s-1. The presented design enables the non-intrusive integration of optical sensors directly on leaves and needles for extended monitoring periods. This work establishes a new hardware approach for distributed leaf-level sensing within environmental monitoring networks, enabling high-resolution observation of vegetation physiological dynamics across spatial and temporal scales.
- Open Access
- 16 February 2026
- Published by Elsevier in Measurement
- Vol. 270
Calibration of multi-spectral photosynthetically active radiation sensor
- 16 February 2026
- Published by Elsevier in Measurement
- Vol. 270
Open AccessCalibration of multi-spectral photosynthetically active radiation sensor
- Open Access
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
The Angular Response of a Multi-Spectral Sensor Poured in a Transparent PDMS Substrate
The measurement of photosynthetically active radiation (PAR) has been done for decades. However, the direct measurement of PAR on the leaf of a tree over the whole vegetation period without causing harm to the plant has remained a challenge. To this end, we propose a small, transparent, and flexible sensor head to measure the PAR. This sensor is based on the multi-spectral sensor AS7341 embedded into a transparent and flexible PDMS substrate. The matrix arrangement of the channels of the AS7341 makes the sensor susceptible to light from different directions. The goal of this work is to investigate two aspects: (1) the angular response of the single channels for different diffuser setups and (2) whether the angular response changes if the sensor is poured into the PDMS. It was demonstrated that with a diffuser, the difference in the angular response of the channels is negligible. Furthermore, we demonstrate why the clear channel should not be utilized for PAR calculations. Finally, we illustrate how a poor opto-mechanical design of the PDMS mold can result in a small anomaly, which can easily be avoided. This work clarifies the question of how to design a flexible leaf sensing system on the example of a multi-spectral PAR sensor.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessThe Angular Response of a Multi-Spectral Sensor Poured in a Transparent PDMS Substrate
The measurement of photosynthetically active radiation (PAR) has been done for decades. However, the direct measurement of PAR on the leaf of a tree over the whole vegetation period without causing harm to the plant has remained a challenge. To this end, we propose a small, transparent, and flexible sensor head to measure the PAR. This sensor is based on the multi-spectral sensor AS7341 embedded into a transparent and flexible PDMS substrate. The matrix arrangement of the channels of the AS7341 makes the sensor susceptible to light from different directions. The goal of this work is to investigate two aspects: (1) the angular response of the single channels for different diffuser setups and (2) whether the angular response changes if the sensor is poured into the PDMS. It was demonstrated that with a diffuser, the difference in the angular response of the channels is negligible. Furthermore, we demonstrate why the clear channel should not be utilized for PAR calculations. Finally, we illustrate how a poor opto-mechanical design of the PDMS mold can result in a small anomaly, which can easily be avoided. This work clarifies the question of how to design a flexible leaf sensing system on the example of a multi-spectral PAR sensor.
- 19 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Calibration Method for Multi-Spectral Par Sensor
Photosynthetically Active Radiation (PAR) sensors are essential tools in plant stress monitoring, ecophysiology, and forest growth modeling. Recently, multi-spectral PAR sensors have emerged as promising alternatives to conventional singlechannel systems, offering comparable accuracy and additional spectral information. However, existing calibration methods rely on single-channel references under variable ambient light conditions, which limits their reliability across diverse lighting environments. This study introduces a novel calibration methodology conducted in a controlled light environment to ensure consistent, reproducible calibration independent of external light variability. The Partial Least Squares (PLS) regression model was tailored for this application by integrating the optical properties of the system components through a customized preprocessing framework. PLS effectively manages collinearity among spectral channels, generating individual calibration coefficients while compensating for spectral leakage, particularly in the nearinfrared range. The proposed calibration approach is validated through field experiments under varying weather conditions, demonstrating a normalized RMSE of just 3.92% compared to a commercial PAR sensor. To support further research, all calibration data and processing tools are publicly available in an open-access repository.
- 19 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Calibration Method for Multi-Spectral Par Sensor
Photosynthetically Active Radiation (PAR) sensors are essential tools in plant stress monitoring, ecophysiology, and forest growth modeling. Recently, multi-spectral PAR sensors have emerged as promising alternatives to conventional singlechannel systems, offering comparable accuracy and additional spectral information. However, existing calibration methods rely on single-channel references under variable ambient light conditions, which limits their reliability across diverse lighting environments. This study introduces a novel calibration methodology conducted in a controlled light environment to ensure consistent, reproducible calibration independent of external light variability. The Partial Least Squares (PLS) regression model was tailored for this application by integrating the optical properties of the system components through a customized preprocessing framework. PLS effectively manages collinearity among spectral channels, generating individual calibration coefficients while compensating for spectral leakage, particularly in the nearinfrared range. The proposed calibration approach is validated through field experiments under varying weather conditions, demonstrating a normalized RMSE of just 3.92% compared to a commercial PAR sensor. To support further research, all calibration data and processing tools are publicly available in an open-access repository.
- Open Access
- 19 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (21) , 40609-40622
Task-Specific Energy Profiling for Microcontroller Selection in Energy-Autonomous Wireless Sensor Nodes
The vigilant monitoring of climate change, especially through advanced environmental sensing and the deployment of distributed sensor systems, establishes a crucial link to the well-being of forest ecosystems. To ensure long term deployment and maintenance-free operation, such sensor systems need to be energy-autonomous, for example, be powered by harvested solar energy. However, given the complexity of the data processing required at the sensor node, the incoming harvested energy is limited with respect to the energy demands. Additionally, the size and the weight of the solar cells is further reduced from the need to have compact sensor systems, which do not interfere with the ecological processes. Under these circumstances, the electronics are forced to consume as low energy as possible and thus, selecting an ultra-low-power microcontroller, as the WSN’s central building block, that effectively balances minimal energy consumption and computational capabilities becomes critical to ensure reliable, autonomous operation. However, existing literature lacks practical methodologies for selecting ultra-low-power microcontrollers based on realistic, task-specific workloads. To address this gap, we introduce a novel task-specific profiling methodology tailored specifically for evaluating ultra-low-power microcontrollers in environmental WSNs. Two representative microcontrollers—the Ambiq Apollo 3 (ARM Cortex M4F-based) and Texas Instruments’ MSP430FR5994—were rigorously assessed in sensor data acquisition, intensive mathematical computations, memory operations, and LoRa-based wireless communication. Unlike conventional datasheet-based evaluations, our method offers empirical, workload-specific insights and enables the derivation of additional metrics such as energy per CPU cycle, which developers can leverage to make application-aware optimization decisions. Our results show clear trade-offs: MSP430FR5994 excels in integrated memory tasks, while Apollo 3 significantly outperforms in sensing and wireless communication, reducing total active-mode energy consumption by around 19.84%. Moreover, Apollo 3 achieved approximately 62% lower deep-sleep energy consumption when paired with an external ultra-low-power real-time clock (RTC). Overall, this study not only identifies the Apollo 3 as the optimal choice for our specific forest-based environmental monitoring case study but also introduces a platform-agnostic profiling framework. As this methodology quantifies energy per task and even energy per CPU cycle, it can be readily applied to diverse deployment contexts, from urban air quality monitoring to agricultural applications, and can be applied to a wide range of microcontroller architectures, including ARM Cortex, MSP430, and emerging RISC-V platforms. However, while the methodology is broadly applicable, it is not intended as a universal design methodology. Instead, it serves as a practical decision-support framework that complements system-level optimization strategies and enables developers to make energy-aware design choices in resource-constrained environments.
- 19 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (21) , 40609-40622
Open AccessTask-Specific Energy Profiling for Microcontroller Selection in Energy-Autonomous Wireless Sensor Nodes
The vigilant monitoring of climate change, especially through advanced environmental sensing and the deployment of distributed sensor systems, establishes a crucial link to the well-being of forest ecosystems. To ensure long term deployment and maintenance-free operation, such sensor systems need to be energy-autonomous, for example, be powered by harvested solar energy. However, given the complexity of the data processing required at the sensor node, the incoming harvested energy is limited with respect to the energy demands. Additionally, the size and the weight of the solar cells is further reduced from the need to have compact sensor systems, which do not interfere with the ecological processes. Under these circumstances, the electronics are forced to consume as low energy as possible and thus, selecting an ultra-low-power microcontroller, as the WSN’s central building block, that effectively balances minimal energy consumption and computational capabilities becomes critical to ensure reliable, autonomous operation. However, existing literature lacks practical methodologies for selecting ultra-low-power microcontrollers based on realistic, task-specific workloads. To address this gap, we introduce a novel task-specific profiling methodology tailored specifically for evaluating ultra-low-power microcontrollers in environmental WSNs. Two representative microcontrollers—the Ambiq Apollo 3 (ARM Cortex M4F-based) and Texas Instruments’ MSP430FR5994—were rigorously assessed in sensor data acquisition, intensive mathematical computations, memory operations, and LoRa-based wireless communication. Unlike conventional datasheet-based evaluations, our method offers empirical, workload-specific insights and enables the derivation of additional metrics such as energy per CPU cycle, which developers can leverage to make application-aware optimization decisions. Our results show clear trade-offs: MSP430FR5994 excels in integrated memory tasks, while Apollo 3 significantly outperforms in sensing and wireless communication, reducing total active-mode energy consumption by around 19.84%. Moreover, Apollo 3 achieved approximately 62% lower deep-sleep energy consumption when paired with an external ultra-low-power real-time clock (RTC). Overall, this study not only identifies the Apollo 3 as the optimal choice for our specific forest-based environmental monitoring case study but also introduces a platform-agnostic profiling framework. As this methodology quantifies energy per task and even energy per CPU cycle, it can be readily applied to diverse deployment contexts, from urban air quality monitoring to agricultural applications, and can be applied to a wide range of microcontroller architectures, including ARM Cortex, MSP430, and emerging RISC-V platforms. However, while the methodology is broadly applicable, it is not intended as a universal design methodology. Instead, it serves as a practical decision-support framework that complements system-level optimization strategies and enables developers to make energy-aware design choices in resource-constrained environments.
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (6) , 7711-7728
A Low-Power Optical Sensor With Dynamically Adjustable Field of View for Photosynthetically Active Radiation (PAR) Measurement
The characterization of light as photosynthetically active radiation (PAR) is crucial for modeling and monitoring plant metabolism and development. Existing intercepted PAR sensing solutions are limited by the requirement to average many below-canopy measurements to account for heterogeneity in the plant canopy, which requires a human operator. In this work, we address this issue by introducing a novel sensing concept to measure the light coming from different areas of the tree canopy with a single sensor by dynamically varying the sensor’s field of view in the zenith and azimuth directions. The sensing system consists of (1) an imaging lens that collects the incoming light, (2) a programmable Liquid-Crystal Display (LCD), which acts as an optical shutter, (3) a diffuser, and (4) the AS7341 multispectral sensor. In this work, the PAR model required to calibrate the sensor is derived and the sensing system is calibrated and characterized. A sensor prototype is then assembled, calibrated, and characterized, achieving competitive performance with a mean average percentage error of 6.78% and a normalized root mean square error of 4.82% on PAR measurements. Tests using a custom LED test sphere show that the sensor has a spatial resolution of 7° and 15° in the θ and ϕ directions, respectively. With a power consumption of 19.54mW mainly attributable to the LCD, our new sensing system could be used for more than two years at one hour of measurements per day, which paves the way towards long-term continuous monitoring of PAR.
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (6) , 7711-7728
A Low-Power Optical Sensor With Dynamically Adjustable Field of View for Photosynthetically Active Radiation (PAR) Measurement
The characterization of light as photosynthetically active radiation (PAR) is crucial for modeling and monitoring plant metabolism and development. Existing intercepted PAR sensing solutions are limited by the requirement to average many below-canopy measurements to account for heterogeneity in the plant canopy, which requires a human operator. In this work, we address this issue by introducing a novel sensing concept to measure the light coming from different areas of the tree canopy with a single sensor by dynamically varying the sensor’s field of view in the zenith and azimuth directions. The sensing system consists of (1) an imaging lens that collects the incoming light, (2) a programmable Liquid-Crystal Display (LCD), which acts as an optical shutter, (3) a diffuser, and (4) the AS7341 multispectral sensor. In this work, the PAR model required to calibrate the sensor is derived and the sensing system is calibrated and characterized. A sensor prototype is then assembled, calibrated, and characterized, achieving competitive performance with a mean average percentage error of 6.78% and a normalized root mean square error of 4.82% on PAR measurements. Tests using a custom LED test sphere show that the sensor has a spatial resolution of 7° and 15° in the θ and ϕ directions, respectively. With a power consumption of 19.54mW mainly attributable to the LCD, our new sensing system could be used for more than two years at one hour of measurements per day, which paves the way towards long-term continuous monitoring of PAR.