Kody Oyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kody Oyama has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Kelvin Shi
Department of Ophthalmology, Mayo Clinic, Jacksonville, FL, USA
2 shared publications - Melanie Wang
Department of Medicine, Carle Illinois College of Medicine, Urbana, IL, USA
2 shared publications Raphael G Banoub
Department of Ophthalmology, Mayo Clinic, Jacksonville, FL, USA
2 shared publications- Ryan Thé
Department of Medicine, Wayne State University School of Medicine, Detroit, MI, USA
2 shared publications Alexander Davies
Oregon Health and Science University
1 shared publication- Alexander E. Davies
Oregon Health and Science University
1 shared publication
Latest Publications
- Open Access
- 1 October 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-17
Safety and Efficacy of the Ahmed ClearPath versus Ahmed ClearPath Small Tube at Six Months: A Retrospective Comparative Cohort Study
Purpose: To compare the safety and efficacy of the Ahmed ClearPath® (ACP) and Ahmed ClearPath® Small Tube (ACP-ST) in the management of glaucoma. Methods: This retrospective comparative study included 15 ACP eyes and 15 ACP-ST eyes. Outcomes compared through 6 months included intraoperative pressure (IOP), medication burden, surgical success, BCVA, and complications. Complete surgical success was definied as a ≥ 20% reduction in IOP from baseline with postoperative IOP > 5 mmHg and no additional glaucoma surgery or medication. Results: Baseline IOP and medication were similar between cohorts. At 6 months, mean IOP decreased from 28.13 ± 7.68 to 10.73 ± 3.63 mmHg in the ACP cohort (p < 0.0001) and from 27.15 ± 6.72 to 12.00 ± 5.32 mmHg in the ACP-ST cohort (p = 0.0001), with no significant difference between groups (p = 0.4535). Mean medication use decreased from 2.93 ± 0.80 to 0.73 ± 1.03 in the ACP cohort (p = 0.0005) and from 3.47 ± 1.46 to 1.00 ± 1.00 in the ACP-ST cohort (p < 0.0001), with no significant difference between groups (p = 0.4785). No intraoperative complications, postoperative hypotony, or IOP spikes occurred in either cohort. Conclusions: Preliminary findings suggest that the ACP-ST may achieve IOP and medication reductions comparable to the ACP through 6 months. No postoperative hypotony was observed in the ACP-ST cohort despite the absence of tube ligation. However, given the sample size and differences in surgical technique, larger prospective controlled studies are needed to determine whether the smaller lumen independently contributes to flow control.
- 1 October 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-17
Open AccessSafety and Efficacy of the Ahmed ClearPath versus Ahmed ClearPath Small Tube at Six Months: A Retrospective Comparative Cohort Study
Purpose: To compare the safety and efficacy of the Ahmed ClearPath® (ACP) and Ahmed ClearPath® Small Tube (ACP-ST) in the management of glaucoma. Methods: This retrospective comparative study included 15 ACP eyes and 15 ACP-ST eyes. Outcomes compared through 6 months included intraoperative pressure (IOP), medication burden, surgical success, BCVA, and complications. Complete surgical success was definied as a ≥ 20% reduction in IOP from baseline with postoperative IOP > 5 mmHg and no additional glaucoma surgery or medication. Results: Baseline IOP and medication were similar between cohorts. At 6 months, mean IOP decreased from 28.13 ± 7.68 to 10.73 ± 3.63 mmHg in the ACP cohort (p < 0.0001) and from 27.15 ± 6.72 to 12.00 ± 5.32 mmHg in the ACP-ST cohort (p = 0.0001), with no significant difference between groups (p = 0.4535). Mean medication use decreased from 2.93 ± 0.80 to 0.73 ± 1.03 in the ACP cohort (p = 0.0005) and from 3.47 ± 1.46 to 1.00 ± 1.00 in the ACP-ST cohort (p < 0.0001), with no significant difference between groups (p = 0.4785). No intraoperative complications, postoperative hypotony, or IOP spikes occurred in either cohort. Conclusions: Preliminary findings suggest that the ACP-ST may achieve IOP and medication reductions comparable to the ACP through 6 months. No postoperative hypotony was observed in the ACP-ST cohort despite the absence of tube ligation. However, given the sample size and differences in surgical technique, larger prospective controlled studies are needed to determine whether the smaller lumen independently contributes to flow control.
- Open Access
- 3 June 2026
- Published by Springer Nature in Research Square
A Single-Cell Bioprinting Method to Reconstruct Native Cellular Microenvironments with Subcellular Resolution
Tissue development and function are determined by the spatial organization of individual cells and their interactions. Yet experimental platforms capable of reconstructing cellular organization with single-cell precision for systematic interrogation remain lacking. Here we introduce a single-cell bioprinting platform that enables programmable reconstruction of cellular microenvironments through controlled single-cell placement with down to subcellular spatial control. We demonstrate intercellular spacing down to 1.3 µm, multiplexed deposition of up to eight cell types within a single construct, and reconstruction of biopsy-derived native cellular organization with 99% accuracy for single-cell placement relative to their native tissue coordinates. Using this framework, we show that manipulation of cellular arrangement allows for controlled interrogation of spatial transcriptional programs, cell–cell signaling networks, and migration dynamics in complex tissue microenvironments. This platform provides a generalizable experimental framework for causal interrogation of spatially defined cell–cell interactions at single-cell resolution.
- 3 June 2026
- Published by Springer Nature in Research Square
Open AccessA Single-Cell Bioprinting Method to Reconstruct Native Cellular Microenvironments with Subcellular Resolution
Tissue development and function are determined by the spatial organization of individual cells and their interactions. Yet experimental platforms capable of reconstructing cellular organization with single-cell precision for systematic interrogation remain lacking. Here we introduce a single-cell bioprinting platform that enables programmable reconstruction of cellular microenvironments through controlled single-cell placement with down to subcellular spatial control. We demonstrate intercellular spacing down to 1.3 µm, multiplexed deposition of up to eight cell types within a single construct, and reconstruction of biopsy-derived native cellular organization with 99% accuracy for single-cell placement relative to their native tissue coordinates. Using this framework, we show that manipulation of cellular arrangement allows for controlled interrogation of spatial transcriptional programs, cell–cell signaling networks, and migration dynamics in complex tissue microenvironments. This platform provides a generalizable experimental framework for causal interrogation of spatially defined cell–cell interactions at single-cell resolution.
- Open Access
- 1 June 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-10
Novel Non-Valved Glaucoma Drainage Device with Reduced Inner Lumen Diameter: 6-Month Safety and Efficacy Outcomes
Purpose: To evaluate the safety and clinical efficacy of the Ahmed ClearPath® Small Tube (ACP-ST), a novel non-valved glaucoma drainage device with a reduced inner lumen diameter, in the management of glaucoma. Methods: This retrospective chart review included 17 eyes that underwent ACP-ST implantation between February 25, 2025, and November 24, 2025. Surgical success was defined as a ≥ 20% reduction in IOP from baseline with a postoperative IOP > 5 mmHg and no need for additional surgical intervention. Changes in IOP, glaucoma medication burden, and best-corrected visual acuity (BCVA) were evaluated through 6 months. Intraoperative and postoperative complications were recorded. Results: Fourteen eyes had available 6-month follow-up data. Mean IOP decreased from 27.19 ± 6.29 mmHg at baseline to 12.21 ± 5.45 mmHg at 6 months, representing a 55.1% reduction (P < 0.0001). Mean glaucoma medication use decreased from 3.35 ± 1.14 to 1.07 ± 0.99 medications, corresponding to a 68.1% reduction (P < 0.0001). Surgical success was achieved in all 14 eyes (100%) with available 6-month follow-up. No intraoperative complications occurred, and no cases of postoperative hypotony or IOP spikes were observed. Conclusion: These preliminary findings suggest that ACP-ST may achieve clinically meaningful reductions in IOP and glaucoma medication burden while maintaining a favorable short-term safety profile, as no cases of postoperative hypotony or IOP spikes were observed. However, given the retrospective design, small sample size, and limited duration of follow-up, further longitudinal studies with larger cohorts will be necessary to better evaluate the durability and long-term safety of ACP-ST.
- 1 June 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-10
Open AccessNovel Non-Valved Glaucoma Drainage Device with Reduced Inner Lumen Diameter: 6-Month Safety and Efficacy Outcomes
Purpose: To evaluate the safety and clinical efficacy of the Ahmed ClearPath® Small Tube (ACP-ST), a novel non-valved glaucoma drainage device with a reduced inner lumen diameter, in the management of glaucoma. Methods: This retrospective chart review included 17 eyes that underwent ACP-ST implantation between February 25, 2025, and November 24, 2025. Surgical success was defined as a ≥ 20% reduction in IOP from baseline with a postoperative IOP > 5 mmHg and no need for additional surgical intervention. Changes in IOP, glaucoma medication burden, and best-corrected visual acuity (BCVA) were evaluated through 6 months. Intraoperative and postoperative complications were recorded. Results: Fourteen eyes had available 6-month follow-up data. Mean IOP decreased from 27.19 ± 6.29 mmHg at baseline to 12.21 ± 5.45 mmHg at 6 months, representing a 55.1% reduction (P < 0.0001). Mean glaucoma medication use decreased from 3.35 ± 1.14 to 1.07 ± 0.99 medications, corresponding to a 68.1% reduction (P < 0.0001). Surgical success was achieved in all 14 eyes (100%) with available 6-month follow-up. No intraoperative complications occurred, and no cases of postoperative hypotony or IOP spikes were observed. Conclusion: These preliminary findings suggest that ACP-ST may achieve clinically meaningful reductions in IOP and glaucoma medication burden while maintaining a favorable short-term safety profile, as no cases of postoperative hypotony or IOP spikes were observed. However, given the retrospective design, small sample size, and limited duration of follow-up, further longitudinal studies with larger cohorts will be necessary to better evaluate the durability and long-term safety of ACP-ST.
- Open Access
A Single-Cell Bioprinting Method to Reconstruct Native Cellular Microenvironments with Subcellular Resolution
Tissue development and function are determined by the spatial organization of individual cells and their interactions. Yet experimental platforms capable of reconstructing cellular organization with single-cell precision for systematic interrogation remain lacking. Here we introduce a single-cell bioprinting platform that enables programmable reconstruction of cellular microenvironments through controlled single-cell placement with down to subcellular spatial control. We demonstrate intercellular spacing down to 1.3 μm, multiplexed deposition of up to eight cell types within a single construct, and reconstruction of biopsy-derived native cellular organization with 99% accuracy for single-cell placement relative to their native tissue coordinates. Using this framework, we show that manipulation of cellular arrangement allows for controlled interrogation of spatial transcriptional programs, cell-cell signaling networks, and migration dynamics in complex tissue microenvironments. This platform provides a generalizable experimental framework for causal interrogation of spatially defined cell-cell interactions at single-cell resolution.
Open AccessA Single-Cell Bioprinting Method to Reconstruct Native Cellular Microenvironments with Subcellular Resolution
Tissue development and function are determined by the spatial organization of individual cells and their interactions. Yet experimental platforms capable of reconstructing cellular organization with single-cell precision for systematic interrogation remain lacking. Here we introduce a single-cell bioprinting platform that enables programmable reconstruction of cellular microenvironments through controlled single-cell placement with down to subcellular spatial control. We demonstrate intercellular spacing down to 1.3 μm, multiplexed deposition of up to eight cell types within a single construct, and reconstruction of biopsy-derived native cellular organization with 99% accuracy for single-cell placement relative to their native tissue coordinates. Using this framework, we show that manipulation of cellular arrangement allows for controlled interrogation of spatial transcriptional programs, cell-cell signaling networks, and migration dynamics in complex tissue microenvironments. This platform provides a generalizable experimental framework for causal interrogation of spatially defined cell-cell interactions at single-cell resolution.