Tuure Nurminen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tuure Nurminen has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Marko Hinkkanen
Department of Electrical Engineering and Automation, Aalto University, Espoo, Finland
4 shared publications - Rayane Mourouvin
Department of Electrical Engineering and Automation, Aalto University, Espoo, Finland
4 shared publications Jarno Kukkola
ABB Oy Drives, Helsinki, Finland
2 shared publications- David Reigosa
Department of Electrical Engineering, University of Oviedo, Gijn, Spain
1 shared publication - Fernando Briz
University of Oviedo
1 shared publication - Jarno Kukkola
ABB Oy Drives, Helsinki, Finland
1 shared publication
Latest Publications
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-12
Multi-Frequency State-Feedback Current Control for Active Power Filters
Proportional-integral and resonant controllers are widely used for active power filter (APF) control. Alternatively to these well-know approaches, state-feedback current control could be used. State-feedback current control has been previously proposed for grid-connected converters, potentially enabling better dynamic performance. However, command tracking capability when multiple current harmonics are controlled has not yet been reported. This aspect is highly relevant if the APF is used for current harmonics cancellation to ensure compliance with grid codes. This paper addresses the design and implementation of state-feedback current control with a reduced-order disturbance observer for harmonic current compensation in APFs. Frequency response function-based analysis will be used for this purpose. Simulation and experimental results will be provided to validate the analysis.
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-12
Multi-Frequency State-Feedback Current Control for Active Power Filters
Proportional-integral and resonant controllers are widely used for active power filter (APF) control. Alternatively to these well-know approaches, state-feedback current control could be used. State-feedback current control has been previously proposed for grid-connected converters, potentially enabling better dynamic performance. However, command tracking capability when multiple current harmonics are controlled has not yet been reported. This aspect is highly relevant if the APF is used for current harmonics cancellation to ensure compliance with grid codes. This paper addresses the design and implementation of state-feedback current control with a reduced-order disturbance observer for harmonic current compensation in APFs. Frequency response function-based analysis will be used for this purpose. Simulation and experimental results will be provided to validate the analysis.
- Open Access
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (6) , 9439-9451
Design and Sensitivity Analysis of Grid-Forming Converter Control Based on a Disturbance Observer
A control method is proposed for grid-forming converters equipped with an LCL filter. Input-output feedback linearization is used for the design of the proposed control method, where active power and voltage magnitude are directly controlled. The proposed control method has a disturbance observer that provides integral action. Transparent current control is included for fault ride-through purposes. The proposed control method allows the closed-loop poles to be freely placed in a simple manner. Sensitivity is analyzed to study the impact of parameter errors on the proposed control method. The analysis results are experimentally verified with a 12.5-kVA converter, demonstrating the excellent dynamic performance of the proposed method for both strong and weak grids in the presence of grid inductance estimation error.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (6) , 9439-9451
Open AccessDesign and Sensitivity Analysis of Grid-Forming Converter Control Based on a Disturbance Observer
A control method is proposed for grid-forming converters equipped with an LCL filter. Input-output feedback linearization is used for the design of the proposed control method, where active power and voltage magnitude are directly controlled. The proposed control method has a disturbance observer that provides integral action. Transparent current control is included for fault ride-through purposes. The proposed control method allows the closed-loop poles to be freely placed in a simple manner. Sensitivity is analyzed to study the impact of parameter errors on the proposed control method. The analysis results are experimentally verified with a 12.5-kVA converter, demonstrating the excellent dynamic performance of the proposed method for both strong and weak grids in the presence of grid inductance estimation error.
- Open Access
- 30 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (6) , 7789-7799
Direct DC-Bus Control for Grid-Forming Converters: Toward the Concept of Dual-Voltage-Forming Converters
A control method for regulating both dc- and ac-side voltages, based on a disturbance observer, is presented. This method provides a voltage-source behavior from the ac-side perspective, a key functionality of grid-forming converters. A dynamic model is derived to develop the control law using feedback linearization. The control method is able to maintain the dc- and ac-side voltages without any cascaded loops. The method is, therefore, named the dual-voltage forming method to differentiate it from the recent definitions of grid-forming converters. The use of a disturbance observer provides integral action and also inherent synchronization. A transparent current controller is implemented to protect the converter from overcurrents. Small-signal stability of the proposed method is studied analytically and design guidelines are drawn from the analysis. Furthermore, the asymmetric behavior of the converter in different operating modes is analytically assessed. The performance of the method is tested in experimental conditions using a 12.5-kVA test setup. The control method exhibits robust performance in both strong and weak grids in terms of dc-bus voltage reference tracking as well as the capacity to survive large external power variations with power-flow direction changes. Moreover, the effect of a grid voltage sag is studied.
- 30 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (6) , 7789-7799
Open AccessDirect DC-Bus Control for Grid-Forming Converters: Toward the Concept of Dual-Voltage-Forming Converters
A control method for regulating both dc- and ac-side voltages, based on a disturbance observer, is presented. This method provides a voltage-source behavior from the ac-side perspective, a key functionality of grid-forming converters. A dynamic model is derived to develop the control law using feedback linearization. The control method is able to maintain the dc- and ac-side voltages without any cascaded loops. The method is, therefore, named the dual-voltage forming method to differentiate it from the recent definitions of grid-forming converters. The use of a disturbance observer provides integral action and also inherent synchronization. A transparent current controller is implemented to protect the converter from overcurrents. Small-signal stability of the proposed method is studied analytically and design guidelines are drawn from the analysis. Furthermore, the asymmetric behavior of the converter in different operating modes is analytically assessed. The performance of the method is tested in experimental conditions using a 12.5-kVA test setup. The control method exhibits robust performance in both strong and weak grids in terms of dc-bus voltage reference tracking as well as the capacity to survive large external power variations with power-flow direction changes. Moreover, the effect of a grid voltage sag is studied.
- Open Access
- 25 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (10) , 13023-13032
Multifunctional Grid-Forming Converter Control Based on a Disturbance Observer
A multifunctional grid-forming control method based on a disturbance observer structure is proposed for grid converters. The proposed method has several different control modes, including the grid-forming, grid-following, and current control modes. The proposed method does not require any separate synchronization loop as it is incorporated in the disturbance observer. Links to existing control methods are shown and tuning recommendations are provided based on small-signal stability analysis. Furthermore, robustness against the inductance error in the grid-forming mode is analytically shown. Experiments with a 12.5-kVA converter are used to assess power-tracking performance. The method is shown to have excellent dynamic performance regardless of grid strength and to provide seamless switching between grid-forming and grid-following modes. In addition, the effect of grid voltage sags and grid-frequency deviations is studied.
- 25 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (10) , 13023-13032
Open AccessMultifunctional Grid-Forming Converter Control Based on a Disturbance Observer
A multifunctional grid-forming control method based on a disturbance observer structure is proposed for grid converters. The proposed method has several different control modes, including the grid-forming, grid-following, and current control modes. The proposed method does not require any separate synchronization loop as it is incorporated in the disturbance observer. Links to existing control methods are shown and tuning recommendations are provided based on small-signal stability analysis. Furthermore, robustness against the inductance error in the grid-forming mode is analytically shown. Experiments with a 12.5-kVA converter are used to assess power-tracking performance. The method is shown to have excellent dynamic performance regardless of grid strength and to provide seamless switching between grid-forming and grid-following modes. In addition, the effect of grid voltage sags and grid-frequency deviations is studied.
- Open Access
- 26 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Multifunctional Grid-Forming Converter Control Based on a Disturbance Observer
A multifunctional grid-forming control method based on a disturbance observer structure is presented for grid converters. The proposed method does not require any separate synchronization loop as it is incorporated in the disturbance observer. Links to existing control methods are shown and tuning recommendations are provided based on small-signal analysis. Experiments with a 12.5-kVA converter are used to assess power-tracking performance. The method is shown to have excellent dynamic performance regardless of grid strength and to have seamless mode switching. Additionally, the effect of symmetrical grid voltage sags and grid-frequency deviations is studied.
- 26 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessMultifunctional Grid-Forming Converter Control Based on a Disturbance Observer
A multifunctional grid-forming control method based on a disturbance observer structure is presented for grid converters. The proposed method does not require any separate synchronization loop as it is incorporated in the disturbance observer. Links to existing control methods are shown and tuning recommendations are provided based on small-signal analysis. Experiments with a 12.5-kVA converter are used to assess power-tracking performance. The method is shown to have excellent dynamic performance regardless of grid strength and to have seamless mode switching. Additionally, the effect of symmetrical grid voltage sags and grid-frequency deviations is studied.