LGLevi M. Golston

Levi M. Golston

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Levi M. Golston has a total of 109 co-authors. Here are the top co-authors by number of shared publications:

  • Mark A. Zondlo

    Princeton University

    15 shared publications
  • Da Pan

    Department of Atmospheric Science, Colorado State University, Fort Collins, CO 80523, USA

    10 shared publications
  • Lei Tao

    Department of Civil and Environmental Engineering Princeton University Princeton NJ USA

    8 shared publications
  • Bernhard Buchholz

    German National Metrology Institut, PTB-Braunschweig , Braunschweig 38116 , Germany

    6 shared publications
  • James McSpiritt

    Department of Civil and Environmental Engineering , Princeton University , 59 Olden St ., Princeton , New Jersey 08540 , United States

    6 shared publications
  • Dana R. Caulton

    Department of Civil and Environmental Engineering , Princeton University , 59 Olden St ., Princeton , New Jersey 08540 , United States

    5 shared publications

Latest Publications

  • Open Access

    Description and validation of a carbon monoxide and nitrous oxide instrument for high-altitude airborne science (COMA)

    by Emma L. Yates, Levi M. Golston, James R. Podolske, Laura T. Iraci, Kristen E. Okorn, Caroline Dang, Roy R. Johnson, James Eilers, Richard Kolyer, Ian Astley, et al.

    In this work, we describe the development of the Carbon monOxide Measurement from Ames (COMA) instrument for measurement of carbon monoxide (CO) and nitrous oxide (N2O) aboard NASA's WB-57 high-altitude research aircraft. While COMA has previously flown in the cabin of the NASA P3 platform, here the instrument was modified to operate in a significantly different environment – an unpressurized pallet flying primarily above 12 km (40 000 ft). Modifications were made to the laser to allow for detection of CO and N2O, ruggedization and thermal management were addressed, and a calibration system was designed to quantify the measurement stability in-flight. Testing was conducted in a thermal vacuum chamber to mimic anticipated ambient conditions experienced inside the WB-57 pallet bay and found that the electronic components remained within the thermal limits. COMA was operated successfully during 9 unattended transit flights to and from South Korea and 15 research flights during NASA's Asian summer monsoon Chemical & CLImate Project (ACCLIP) 2022 campaign, which was focused on studying the Asian summer monsoon anticyclone in the western Pacific. The CO measurement has an overall uncertainty ranging between 4.1 ppb (at 50 ppb CO) and 5.6 ppb (at 200 ppb CO). N2O has an overall uncertainty of 2.7 ppb (at 320 ppb N2O). In addition, COMA observations were compared with two other in situ CO instruments co-located on the WB-57: the Carbon Monoxide Laser Detector 2 (COLD2) and the Airborne Carbonic Oxides and Sulfide Spectrometer (ACOS). Comparisons for the 15 flights during the ACCLIP campaign indicate ranges in slope of 1.10–1.15 for COLD2 vs. COMA and 0.94–1.10 for ACOS vs. COMA.

  • Open Access

    Description and Validation of a Carbon Monoxide and Nitrous Oxide Instrument for High-Altitude Airborne Science (COMA)

    by Emma L. Yates, Levi M. Golston, James R. Podolske, Laura T. Iraci, Kristen E. Okorn, Caroline Dang, Roy R. Johnson, James Eilers, Richard Kolyer, Ian Astley, et al.

    In this work, we describe development of the Carbon monOxide Measurement from Ames (COMA) instrument for measurement of carbon monoxide (CO) and nitrous oxide (N2O) aboard NASA's WB-57 high altitude research aircraft. While COMA has previously flown in the cabin of the NASA P-3 platform, here the instrument was modified to operate in a significantly different environment- an unpressurized pallet flying primarily above 12 km (40,000 ft). Modifications were made to the laser to allow for detection of CO and N2O, ruggedization and thermal management were addressed, and a calibration system was designed to quantify the measurement stability in-flight. Testing was conducted in a thermal vacuum chamber to mimic anticipated ambient conditions experienced inside the WB-57 pallet bay and found electronic components remained within thermal limits. COMA successfully operated during nine unattended transit flights to and from South Korea and fifteen research flights during NASA’s Asian summer monsoon Chemical & CLImate Project (ACCLIP) 2022 campaign, which was focused on studying the Asian summer monsoon anticyclone in the Western Pacific. The CO measurement has an overall uncertainty ranging between 4.1 ppb (at 50 ppb CO) and 5.9 ppb (at 200 ppb CO). N2O has an overall uncertainty of 2.7 ppb (at 320 ppb N2O). In addition, COMA observations were compared with two other in-situ CO instruments co-located on the WB-57: Carbon Monoxide Laser Detector (COLD) 2 and Airborne Carbonic Oxides and Sulfide Spectrometer (ACOS). Comparisons for 15 flights during the ACCLIP campaign indicate a range in slope of 1.10–1.15 for COLD2 vs. COMA and 0.94–1.10 for ACOS vs COMA.


  • Open Access

    Positive anomalies in Carbon Monoxide concentrations observed in the upper troposphere - lower stratosphere during the 2022 Asian summer monsoon season

    by Silvia Viciani, Marco Barucci, Giovanni Bianchini, Teresa Campos, Francesco D'Amato, Caroline Dang, Levi Golstone, Colin Gurganus, Laura Iraci, Alessio Montori, et al.

    In the framework of the ACCLIP project (Asian summer monsoon Chemical and CLimate Impacts project), a measurement campaign was conducted during summer 2022 in the Western Pacific region, to investigate the impact of the Asian Summer Monsoon (ASM) on the composition of the upper troposphere and lower stratosphere (UTLS). Fifteen research flights were carried out by the NASA WB-57 stratospheric aircraft and 14 by the NCAR/NSF GV, with base in Osan (South Korea), covering a large region on the eastern edge of the ASM anticyclone.We report on the Carbon Monoxide (CO) measurements performed by three different mid-infrared absorption spectrometers (COLD2, COMA and ACOS) installed onboard the WB-57 and by two different infrared absorption spectrometers (Aerodyne-CO and Picarro G2401) installed on the GV. Positive CO anomalies, never measured before in the UTLS outside direct biomass burning plumes, were collected by all sensors, showing a very good agreement. During the flight of the 19th of August, CO mixing ratio values higher than 250 ppb were registered at altitude around 14-15 km.A comparison with the CO observations measured by the instrument COLD2 during the StratoClim (Stratospheric and upper tropospheric processes for better Climate predictions) campaign, conducted in summer 2017 from Kathmandu (Nepal), will be presented. Particular attention will be paid to the CO difference observed in the UTLS, by sampling the anticyclone directly from the Tibetan Plateau during StratoClim campaign or from the Western Pacific during ACCLIP.

  • Open Access

    Inter-comparison of different sensors for in-situ airborne measurements of Carbon Monoxide during ACCLIP campaign

    by Francesco D'AMato, Marco Barucci, Giovanni Bianchini, Teresa Campos, Caroline Dang, Levi Golston, Colin Gurganus, Laura Iraci, Alessio Montori, Kristen Okorn, et al.

    A series of in-situ Carbon Monoxide (CO) observations were recently performed in the Western Pacific region, during summer 2022, in the framework of the ACCLIP project (Asian summer monsoon Chemical and CLimate Impacts Project). During the ACCLIP measurements campaign, located in Osan (South Korea), two different research aircraft were employed with a set of sensors installed onboard. The NASA WB-57 aircraft carried out 15 research flights (reaching a maximum altitude of about 19 km), and the NSF/NCAR Gulfstream (GV) aircraft carried out 14 research flights (reaching a maximum altitude of about 15 km), covering a large region near Korea and Japan.We report on the inter-comparison between five different instruments for in-situ CO mixing ratio measurements: three installed onboard WB-57 (ACOS, COLD2 and COMA), and two installed onboard GV (Aerodyne-CO and Picarro G2401-m). COLD2 (Carbon Oxide Laser Detector 2) [1] and Aerodyne-CO [2] are mid-infrared Quantum Cascade Laser spectrometers, based on direct absorption in combination with a multipass cell. ACOS (Carbonyl Sulfide Analyzer) [3] and COMA (Carbon mOnoxide Measurement from Ames) [4] are mid-infrared absorption spectrometers based on Off-Axis ICOS (Integrated Cavity Output Spectroscopy) technology. The Picarro sensor is a cavity ring down absorption spectrometer [5].The in-flight CO mixing ratio values measured by the five spectrometers will be compared, with particular attention to both the accuracy of each instrument and the adopted or not-adopted calibration procedures, as, in principle, for many measurement environments the two sensors based on direct absorption do not need in-flight calibration. Laboratory measurements of common primary and secondary calibration standards made by the five CO measurement groups will be presented to increase confidence in method accuracy. [1] Viciani S., Montori A., Chiarugi A., and D’Amato F.: "A Portable Quantum Cascade Laser Spectrometer for Atmospheric Measurements of Carbon Monoxide", Sensors, 18, 2380 -1-18 (2018).[2] https://www.eol.ucar.edu/instruments/carbon-monoxide-co-and-nitrous-oxide-n%E2%82%82o-qcl-instrument[3] https://ams.confex.com/ams/103ANNUAL/meetingapp.cgi/Paper/421824[4] https://espo.nasa.gov/acclip/instrument/COMA[5] https://www.eol.ucar.edu/instruments/airborne-carbon-dioxide-co2-methane-ch4-carbon-monoxide-co-and-water-vapor-h2o

  • Open Access

    Validation of IASI Satellite Ammonia Observations at the Pixel Scale Using In Situ Vertical Profiles

    by Xuehui Guo, Rui Wang, Da Pan, Mark A. Zondlo, Lieven Clarisse, Martin Van Damme, Simon Whitburn, Pierre‐François Coheur, Cathy Clerbaux, Bruno Franco, et al.

    Satellite ammonia (NH3) observations provide unprecedented insights into NH3 emissions, spatiotemporal variabilities and trends, but validation with in situ measurements remains lacking. Here, total columns from the Infrared Atmospheric Sounding Interferometer (IASI) were intercompared to boundary layer NH3 profiles derived from aircraft‐ and surface‐based measurements primarily in Colorado, USA, in the summer of 2014. IASI‐NH3 version 3 near real‐time data set compared well to in situ derived columns (windows ±15 km around centroid, ±1 h around overpass time) with a correlation of 0.58, a slope of 0.78 ± 0.14 and an intercept of 2.1 × 1015±1.5 × 1015 molecules cm−2. Agreement degrades at larger spatiotemporal windows, consistent with the short atmospheric lifetime of NH3. We also examined IASI version 3R data, which relies on temperature retrievals from the ERA Reanalysis, and a third product generated using aircraft‐measured temperature profiles. The overall agreement improves slightly for both cases, and neither is biased within their combined measurement errors. Thus, spatiotemporal averaging of IASI over large windows can be used to reduce retrieval noise. Nonetheless, sampling artifacts of airborne NH3 instruments result in significant uncertainties of the in situ‐derived columns. For example, large validation differences exist between ascent and descent profiles, and the assumptions of the free tropospheric NH3 profiles used above the aircraft ceiling significantly impact the validation. Because short‐lived species like NH3 largely reside within the boundary layer with complex vertical structures, more comprehensive validation is needed across a wide range of environments. More accurate and widespread in situ NH3 data sets are therefore required for improved validations of satellite products.


  • Open Access

    Methane emissions from natural gas vehicles in China

    by Da Pan, Lei Tao, Kang Sun, Levi M. Golston, David J. Miller, Tong Zhu, Yue Qin, Yan Zhang, Denise L. Mauzerall, Mark A. Zondlo

    Natural gas vehicles (NGVs) have been promoted in China to mitigate air pollution, yet our measurements and analyses show that NGV growth in China may have significant negative impacts on climate change. We conducted real-world vehicle emission measurements in China and found high methane emissions from heavy-duty NGVs (90% higher than current emission limits). These emissions have been ignored in previous emission estimates, leading to biased results. Applying our observations to life-cycle analyses, we found that switching to NGVs from conventional vehicles in China has led to a net increase in greenhouse gas (GHG) emissions since 2000. With scenario analyses, we also show that the next decade will be critical for China to reverse the trend with the upcoming China VI standard for heavy-duty vehicles. Implementing and enforcing the China VI standard is challenging, and the method demonstrated here can provide critical information regarding the fleet-level CH4 emissions from NGVs.


  • Variability of Ammonia and Methane Emissions from Animal Feeding Operations in Northeastern Colorado

    by Levi M. Golston, Da Pan, Kang Sun, Lei Tao, Mark A. Zondlo, Scott J. Eilerman, Jeff Peischl, J. Andrew Neuman, Cody Floerchinger

    Concentrated animal feeding operations (CAFOs) are major emitters of both ammonia (NH3) and methane (CH4), however, current emission inventories have limited temporal resolution and use data derived from a small subset of farms. To this end, we deployed three mobile laboratories during the DISCOVER-AQ campaign in summer 2014 with a focus on northeastern Colorado. Observations of NH3 and CH4 plumes downwind of 43 CAFOs were used to investigate the diurnal and site-to-site variability of emissions with an inverse area plume modeling approach. Ammonia emissions scaled to all permitted animals in Weld, Morgan, and Larimer counties were estimated at 1.9 Gg month-1, 50% greater than the U.S. NEI 2014 and 360% greater than EDGAR for the month of August. Methane emissions were likewise estimated at 10.6 Gg month-1, consistent with the U.S. GHGI but 99% greater than EDGAR. Significant differences between individual CAFOs with repeat observations were also observed for both CH4 and NH3 emissions. The large sub-farm, site-to-site, and diurnal variabilities observed show the importance of measurements taken across these scales in order to derive representative emission factors.


  • Open Access

    Importance of Superemitter Natural Gas Well Pads in the Marcellus Shale

    by Dana R. Caulton, Jessica M. Lu, Haley M. Lane, Bernhard Buchholz, Jeffrey P. Fitts, Levi M. Golston, Xuehui Guo, Qi Li, James McSpiritt, Da Pan, et al.

    A large-scale study of methane emissions from well pads was conducted in the Marcellus shale (PA), the largest producing natural gas shale play in the U.S., to better identify the prevalence and characteristics of super-emitters. Roughly 2100 measurements were taken from 673 unique unconventional well pads corresponding to ~18% of the total population of active sites and ~32% of the total statewide unconventional natural gas production. A lognormal distribution with a geometric mean of 2.0 kg hr˗1 and arithmetic mean of 5.5 kg hr˗1 was observed, which agrees with other independent observations in this region. The geometric standard deviation (4.4 kg hr˗1) compared well to other studies in the region, but the top 10% of emitters observed in this study contributed 77% of the total emissions, indicating an extremely skewed distribution. The integrated proportional loss of this representative sample is equal to 0.53% with a 95% confidence interval of 0.45–0.64% of the total production of the sites, which is greater than the EPA inventory estimate (0.29%), but in the lower range of other mobile observations (0.09-3.3%). These results emphasize the need for a sufficiently large sample size when characterizing emissions distributions that contain super-emitters.


  • Open Access

    Quantifying uncertainties from mobile-laboratory-derived emissions of well pads using inverse Gaussian methods

    by Dana R. Caulton, Qi Li, Elie Bou-Zeid, Jeffrey P. Fitts, Levi M. Golston, Da Pan, Jessica Lu, Haley M. Lane, Bernhard Buchholz, Xuehui Guo, et al.

    Mobile laboratory measurements provide information on the distribution of CH4 emissions from point sources such as oil and gas wells, but uncertainties are poorly constrained or justified. Sources of uncertainty and bias in ground-based Gaussian-derived emissions estimates from a mobile platform were analyzed in a combined field and modeling study. In a field campaign where 1009 natural gas sites in Pennsylvania were sampled, a hierarchical measurement strategy was implemented with increasing complexity. Of these sites, ∼ 93 % were sampled with an average of 2 transects in < 5 min (standard sampling), ∼ 5 % were sampled with an average of 10 transects in < 15 min (replicate sampling) and ∼ 2 % were sampled with an average of 20 transects in 15–60 min. For sites sampled with 20 transects, a tower was simultaneously deployed to measure high-frequency meteorological data (intensive sampling). Five of the intensive sampling sites were modeled using large eddy simulation (LES) to reproduce CH4 concentrations in a turbulent environment. The LES output and LES-derived emission estimates were used to compare with the results of a standard Gaussian approach. The LES and Gaussian-derived emission rates agreed within a factor of 2 in all except one case; the average difference was 25 %. A controlled release was also used to investigate sources of bias in either technique. The Gaussian method agreed with the release rate more closely than the LES, underlining the importance of inputs as sources of uncertainty for the LES. The LES was also used as a virtual experiment to determine an optimum number of repeat transects and spacing needed to produce representative statistics. Approximately 10 repeat transects spaced at least 1 min apart are required to produce statistics similar to the observed variability over the entire LES simulation period of 30 min. Sources of uncertainty from source location, wind speed, background concentration and atmospheric stability were also analyzed. The largest contribution to the total uncertainty was from atmospheric variability; this is caused by insufficient averaging of turbulent variables in the atmosphere (also known as random errors). Atmospheric variability was quantified by repeat measurements at individual sites under relatively constant conditions. Accurate quantification of atmospheric variability provides a reasonable estimate of the lower bound for emission uncertainty. The uncertainty bounds calculated for this work for sites with > 50 ppb enhancements were 0.05–6.5q (where q is the emission rate) for single-transect sites and 0.5–2.7q for sites with 10+ transects. More transects allow a mean emission rate to be calculated with better precision. It is recommended that future mobile monitoring schemes quantify atmospheric variability, and attempt to minimize it, under representative conditions to accurately estimate emission uncertainty. These recommendations are general to mobile-laboratory-derived emissions from other sources that can be treated as point sources.


  • Open Access

    Natural Gas Fugitive Leak Detection Using an Unmanned Aerial Vehicle: Measurement System Description and Mass Balance Approach

    by Shuting Yang, Robert W. Talbot, Michael B. Frish, Levi M. Golston, Nicholas F. Aubut, Mark A. Zondlo, Christopher Gretencord, James McSpiritt

    Natural gas is an abundant resource across the United States, of which methane (CH4) is the main component. About 2% of extracted CH4 is lost through leaks. The Remote Methane Leak Detector (RMLD)-Unmanned Aerial Vehicle (UAV) system was developed to investigate natural gas fugitive leaks in this study. The system is composed of three major technologies: miniaturized RMLD (mini-RMLD) based on Backscatter Tunable Diode Laser Absorption Spectroscopy (TDLAS), an autonomous quadrotor UAV and simplified quantification and localization algorithms. With a miniaturized, downward-facing RMLD on a small UAV, the system measures the column-integrated CH4 mixing ratio and can semi-autonomously monitor CH4 leakage from sites associated with natural gas production, providing an advanced capability in detecting leaks at hard-to-access sites compared to traditional manual methods. Automated leak characterization algorithms combined with a wireless data link implement real-time leak quantification and reporting. This study placed particular emphasis on the RMLD-UAV system description and the quantification algorithm development based on a mass balance approach. Early data were gathered to test the prototype system and to evaluate the algorithm performance. The quantification algorithm derived in this study tended to underestimate the gas leak rates and yielded unreliable estimations in detecting leaks under 7 × 10 − 6 m3/s (~1 Standard Cubic Feet per Hour (SCFH)). Zero-leak cases can be ascertained via a skewness indicator, which is unique and promising. The influence of the systematic error was investigated by introducing simulated noises, of which Global Positioning System (GPS) noise presented the greatest impact on leak rate errors. The correlation between estimated leak rates and wind conditions were investigated, and steady winds with higher wind speeds were preferred to get better leak rate estimations, which was accurate to approximately 50% during several field trials. High precision coordinate information from the GPS, accurate wind measurements and preferred wind conditions, appropriate flight strategy and the relative steady survey height of the system are the crucial factors to optimize the leak rate estimations.