Chaohui Cui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chaohui Cui has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Cungang Hu
School of Electrical Engineering and Automation, Anhui University, Hefei, China
3 shared publications - Haoran Li
School of Electrical Engineering and Automation, Anhui University, Hefei, China
3 shared publications - Juan Yan
School of Electrical Engineering and Automation, Anhui University, Hefei 230601, China
2 shared publications - Wenping Cao
School of Electrical Engineering and Automation, Anhui University, Hefei, China
2 shared publications - Xi Tang
School of Electrical Engineering and Automation, Anhui Province Engineering Research Center for Advanced Power Electronics and Energy Conversion, Anhui University, Hefei, China
2 shared publications - Donald Grahame Holmes
RMIT University, Melbourne, VIC, Australia
1 shared publication
Latest Publications
- 29 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 15980-15993
10-kV Output Voltage Estimation Method With Sensorless Model for SiC Resonant Pulse Converters in Portable Dielectric Barrier Discharge Applications
The conventional method for evaluating the output voltage in dielectric barrier discharge (DBD) typically relies on high voltage sampling circuits or mathematical models. However, these methods are prone to interference from the high dv/dt generated from DBD loads, and their accuracy is often compromised by parasitic parameters. To address these issues, this paper proposes a s-domain sensorless model for the output voltage estimation of a SiC-based resonant pulse converter. The proposed approach accounts for the nonlinear capacitance of DBD load and incorporates transformer parasitic parameters, enabling accurate output voltage calculation without bulky detection circuits, while offering high immunity to high-voltage and high-frequency noise. Furthermore, a magnetically integrated structure is introduced to maximize power density and achieves a compact system design. The transformer parasitic parameters are extracted carefully to further improve the accuracy of proposed model. A 10-kV SiC DBD prototype has been implemented, capable of operating at pulse repetition frequencies from 5 kHz to 30 kHz, with output voltage adjustment between 1 kV and 10 kV. Experimental results demonstrate that the estimated output voltage achieved using the proposed method aligns with measured values with an accuracy of up to 99.2%. Compared to conventional methods, the proposed approach improves output voltage estimation accuracy by 6.1% and increases power density by 69.4%.
- 29 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 15980-15993
10-kV Output Voltage Estimation Method With Sensorless Model for SiC Resonant Pulse Converters in Portable Dielectric Barrier Discharge Applications
The conventional method for evaluating the output voltage in dielectric barrier discharge (DBD) typically relies on high voltage sampling circuits or mathematical models. However, these methods are prone to interference from the high dv/dt generated from DBD loads, and their accuracy is often compromised by parasitic parameters. To address these issues, this paper proposes a s-domain sensorless model for the output voltage estimation of a SiC-based resonant pulse converter. The proposed approach accounts for the nonlinear capacitance of DBD load and incorporates transformer parasitic parameters, enabling accurate output voltage calculation without bulky detection circuits, while offering high immunity to high-voltage and high-frequency noise. Furthermore, a magnetically integrated structure is introduced to maximize power density and achieves a compact system design. The transformer parasitic parameters are extracted carefully to further improve the accuracy of proposed model. A 10-kV SiC DBD prototype has been implemented, capable of operating at pulse repetition frequencies from 5 kHz to 30 kHz, with output voltage adjustment between 1 kV and 10 kV. Experimental results demonstrate that the estimated output voltage achieved using the proposed method aligns with measured values with an accuracy of up to 99.2%. Compared to conventional methods, the proposed approach improves output voltage estimation accuracy by 6.1% and increases power density by 69.4%.
- 19 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (5) , 5411-5423
GaN-Based LLC Converters With Digital Synchronous Rectifier and Copper Foil Planar Transformer in High-Output Current Applications
With gallium nitride (GaN) switching speed of 3.7 ns, high dv / dt of 105 kV/μs for 390 V poses serious challenges for SR using extra circuit sensing high frequency signal of drain-to-source voltage method. A digital SR algorithm based on charge conservation is proposed, which deduces the SR on-time by calculating the time of current flowing the SR MOSFET junction capacitor. The proposed SR requires no additional detection circuit, which effectively avoids the effect of high dv / dt and minimizes the SR conduction loss to improve the efficiency. Furthermore, in high-output current applications, printed circuit board (PCB) planar transformers face problems of huge winding loss and limited winding current-carrying capacity. A design is proposed for planar transformer using secondary-parallel multiple interleaved copper foil winding. To diminish DC resistance, the secondary side of the transformer is connected in parallel with three copper foil layers. Additionally, the primary and secondary windings are interleaved to achieve lower AC resistance. A 1.5-kW GaN LLC prototype is built with 650 kHz resonant frequency. The LLC power density is 524 W/in 3 and the efficiency is up to 98% with 28 V/53.5 A output at full load.
- 19 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (5) , 5411-5423
GaN-Based LLC Converters With Digital Synchronous Rectifier and Copper Foil Planar Transformer in High-Output Current Applications
With gallium nitride (GaN) switching speed of 3.7 ns, high dv / dt of 105 kV/μs for 390 V poses serious challenges for SR using extra circuit sensing high frequency signal of drain-to-source voltage method. A digital SR algorithm based on charge conservation is proposed, which deduces the SR on-time by calculating the time of current flowing the SR MOSFET junction capacitor. The proposed SR requires no additional detection circuit, which effectively avoids the effect of high dv / dt and minimizes the SR conduction loss to improve the efficiency. Furthermore, in high-output current applications, printed circuit board (PCB) planar transformers face problems of huge winding loss and limited winding current-carrying capacity. A design is proposed for planar transformer using secondary-parallel multiple interleaved copper foil winding. To diminish DC resistance, the secondary side of the transformer is connected in parallel with three copper foil layers. Additionally, the primary and secondary windings are interleaved to achieve lower AC resistance. A 1.5-kW GaN LLC prototype is built with 650 kHz resonant frequency. The LLC power density is 524 W/in 3 and the efficiency is up to 98% with 28 V/53.5 A output at full load.
- 6 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (10) , 12312-12322
Digital Synchronous Rectifier Control Using Extended Harmonics Impedance Model for High-Frequency GaN-Based LLC Converters
Conventional LLC synchronous rectifier (SR) schemes use detection circuits to sense the signals of voltage or current. But it typically operates below 500 kHz, which is unsuitable for high-frequency applications as it may lose large SR duty cycle caused by high dv/dt and GaN devices usage. To address the serious challenge, a digital SR control using extended harmonics impedance model is proposed for GaN LLC converters. By building the impedance model, the SR on-time is calculated accurately in the microcontroller. It not only minimizes the on-time of SR body diode with high precision, but also owns high immunity. A 650-kHz 1.5-kW GaN LLC converter was built. With the output of 28 V/53.5 A, the efficiency is as high as 98.1% at 1.5 kW by using the proposed SR. The power density is also up to 524 W/in 3 . Compared to the conventional SR, the efficiency improves 1.6% at full load.
- 6 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (10) , 12312-12322
Digital Synchronous Rectifier Control Using Extended Harmonics Impedance Model for High-Frequency GaN-Based LLC Converters
Conventional LLC synchronous rectifier (SR) schemes use detection circuits to sense the signals of voltage or current. But it typically operates below 500 kHz, which is unsuitable for high-frequency applications as it may lose large SR duty cycle caused by high dv/dt and GaN devices usage. To address the serious challenge, a digital SR control using extended harmonics impedance model is proposed for GaN LLC converters. By building the impedance model, the SR on-time is calculated accurately in the microcontroller. It not only minimizes the on-time of SR body diode with high precision, but also owns high immunity. A 650-kHz 1.5-kW GaN LLC converter was built. With the output of 28 V/53.5 A, the efficiency is as high as 98.1% at 1.5 kW by using the proposed SR. The power density is also up to 524 W/in 3 . Compared to the conventional SR, the efficiency improves 1.6% at full load.