Johannes Schorr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Johannes Schorr has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Dennis Lam
University of Bradford Chair in Structural Engineering Chesham C2.16 BD7 Bradford UK
2 shared publications - Nadia Baldassino
Universität Trento Universita degli Studi di Trento Dipartimento di Ingegneria Civile Ambientale e Meccanica 38050 Povo (Trento) Italien
2 shared publications - Riccardo Zandonini
Universität Trento Universita degli Studi di Trento Dipartimento di Ingegneria Civile Ambientale e Meccanica 38050 Povo (Trento) Italien
2 shared publications - Therese Sheehan
University of Bradford Chair in Structural Engineering Chesham C2.16 BD7 Bradford UK
2 shared publications - Ulrike Kuhlmann
Universität Stuttgart Institut für Konstruktion und Entwurf Pfaffenwaldring 7 70569 Stuttgart
2 shared publications Dominik Hoffmann
KLEUSBERG GmbH & Co. KG Fürstenwall 70 40219 Düsseldorf Germany
1 shared publication
Latest Publications
- Open Access
- 9 January 2024
- Published by Wiley in Steel Construction
- Vol. 17 (2) , 70-80
Composite girders with short headed studs in grouted joints of precast concrete elements – Numerical investigations and design recommendations
Short headed studs used in grouted joints with precast concrete elements are currently not sufficiently covered by EN 1994‐1‐1. Therefore, three test series have been realised to define the load‐bearing capacity under these special conditions. These are characterised by short headed studs of height hsc=65 mm in combination with a high‐strength grout. For a more in‐depth analysis of the load‐bearing and deformation behaviour, a finite element model has been developed and validated on the conducted push‐out tests. Based on subsequent numerical studies – varying geometric and material parameters – recommendations of analytical model equations are given for headed studs of short length.
- 9 January 2024
- Published by Wiley in Steel Construction
- Vol. 17 (2) , 70-80
Open AccessComposite girders with short headed studs in grouted joints of precast concrete elements – Numerical investigations and design recommendations
Short headed studs used in grouted joints with precast concrete elements are currently not sufficiently covered by EN 1994‐1‐1. Therefore, three test series have been realised to define the load‐bearing capacity under these special conditions. These are characterised by short headed studs of height hsc=65 mm in combination with a high‐strength grout. For a more in‐depth analysis of the load‐bearing and deformation behaviour, a finite element model has been developed and validated on the conducted push‐out tests. Based on subsequent numerical studies – varying geometric and material parameters – recommendations of analytical model equations are given for headed studs of short length.
- Open Access
- 24 September 2020
- Published by Wiley in Steel Construction
- Vol. 13 (4) , 252-263
New approach for the design shear resistance of headed studs in profiled steel sheeting with ribs transverse to supporting beam
This article presents new equations for the design shear resistance of headed studs in solid concrete slabs and new reduction factors that consider the influence of profiled steel sheeting with ribs transverse to the supporting beam. Comparisons with push‐out test results show that the current reduction factor kt in Eurocode 4 does not take sufficiently into account parameters such as geometry or position of the headed stud in the rib. Therefore, the mean shear test results are overestimated by the current equations. When introducing the new approach for the design resistance of headed studs, the main focus is on the description of the basic procedure for the development of the new approach and on the comparison with values in the existing code. Comparisons with push‐out test results from a recent European project have shown the good quality of the new approach.
- 24 September 2020
- Published by Wiley in Steel Construction
- Vol. 13 (4) , 252-263
Open AccessNew approach for the design shear resistance of headed studs in profiled steel sheeting with ribs transverse to supporting beam
This article presents new equations for the design shear resistance of headed studs in solid concrete slabs and new reduction factors that consider the influence of profiled steel sheeting with ribs transverse to the supporting beam. Comparisons with push‐out test results show that the current reduction factor kt in Eurocode 4 does not take sufficiently into account parameters such as geometry or position of the headed stud in the rib. Therefore, the mean shear test results are overestimated by the current equations. When introducing the new approach for the design resistance of headed studs, the main focus is on the description of the basic procedure for the development of the new approach and on the comparison with values in the existing code. Comparisons with push‐out test results from a recent European project have shown the good quality of the new approach.
- Open Access
Design of slim‐floors and their connections between steel and concrete
Slim‐floor beams are composite beams with steel sections integrated into the concrete slab. The small section height together with high bending capacity enables to build large column‐free spaces. Furthermore the reduced height of the slim‐floor structure compared to conventional solutions may allow for more floors in a limited overall building height. Slim‐floor beams achieve a high degree of prefabrication when precast concrete elements or metal decking sheets are used. Accordingly, the construction time can be optimised to a minimum. Further advantages are the very good fire protection and joist free ceilings.Due to the shallow depth of slim‐floor beams their structural response differs from conventional composite structures. Designers should consider additional effects to analyse the deformation behaviour as well as the load carrying behaviour. Based on extensive experimental and numerical investigations, the European research project SlimAPP compiles design principles for slim‐floor constructions in ultimate limit state as well as in serviceability limit state. Some of these rules may be included in Eurocode 4 by Project Team SC4.PT5 “Development of rules covering shallow floor construction, and other flooring types using pre‐cast concrete”. The background and requirements for designing the shear connector system for slim‐floor constructions as well as the utilisation of partial interaction and its influence on the load‐carrying behaviour are presented in this paper.
Open AccessDesign of slim‐floors and their connections between steel and concrete
Slim‐floor beams are composite beams with steel sections integrated into the concrete slab. The small section height together with high bending capacity enables to build large column‐free spaces. Furthermore the reduced height of the slim‐floor structure compared to conventional solutions may allow for more floors in a limited overall building height. Slim‐floor beams achieve a high degree of prefabrication when precast concrete elements or metal decking sheets are used. Accordingly, the construction time can be optimised to a minimum. Further advantages are the very good fire protection and joist free ceilings.Due to the shallow depth of slim‐floor beams their structural response differs from conventional composite structures. Designers should consider additional effects to analyse the deformation behaviour as well as the load carrying behaviour. Based on extensive experimental and numerical investigations, the European research project SlimAPP compiles design principles for slim‐floor constructions in ultimate limit state as well as in serviceability limit state. Some of these rules may be included in Eurocode 4 by Project Team SC4.PT5 “Development of rules covering shallow floor construction, and other flooring types using pre‐cast concrete”. The background and requirements for designing the shear connector system for slim‐floor constructions as well as the utilisation of partial interaction and its influence on the load‐carrying behaviour are presented in this paper.
Anwendungsregeln für Slim‐Floor‐Träger unter Berücksichtigung von Sicherheit, Funktionalität und Nachhaltigkeit
Slim‐Floor‐Träger als teilweise einbetonierte Verbundträger erlauben besonders geringe Konstruktionshöhen bei dennoch großen Spannweiten. Das Ziel des europäischen Forschungsprojekts „SlimAPP – Slim‐Floor Beams – Preparation of Application rules in view of improved safety, functionality and LCA“ war die Verbesserung der Wettbewerbsfähigkeit von Stahlanwendungen in Gebäuden durch die Entwicklung von verlässlichen und vorteilhaften Anwendungsregeln für Slim‐Floor‐Träger in Bezug auf Sicherheit, Funktionalität und Lebenszyklusbewertungen. Neben einem ganzheitlichen Ansatz, der alle Gesichtspunkte eines optimalen technischen und nachhaltigen Entwurfs berücksichtigt, wurde ein besonderer Schwerpunkt auf den Einfluss der Schubtragfähigkeit von effizienten Verbundmitteln aus Betondübeln mit Bewehrungsstählen gelegt. Für Slim‐Floor‐Träger, die bisher im Eurocode 4 nicht berücksichtigt sind, wurde die Anwendung der bekannten Bemessungsregeln geprüft und zum Teil neue Regeln für die Bemessung insbesondere der Betondübel entwickelt. Mithilfe von Beispielen verschiedener Slim‐Floor‐Lösungen wird die Bemessung im Grenzzustand der Tragfähigkeit und Gebrauchstauglichkeit erläutert und mit einer ganzheitlichen Lebenszyklusanalyse untereinander verglichen.
Anwendungsregeln für Slim‐Floor‐Träger unter Berücksichtigung von Sicherheit, Funktionalität und Nachhaltigkeit
Slim‐Floor‐Träger als teilweise einbetonierte Verbundträger erlauben besonders geringe Konstruktionshöhen bei dennoch großen Spannweiten. Das Ziel des europäischen Forschungsprojekts „SlimAPP – Slim‐Floor Beams – Preparation of Application rules in view of improved safety, functionality and LCA“ war die Verbesserung der Wettbewerbsfähigkeit von Stahlanwendungen in Gebäuden durch die Entwicklung von verlässlichen und vorteilhaften Anwendungsregeln für Slim‐Floor‐Träger in Bezug auf Sicherheit, Funktionalität und Lebenszyklusbewertungen. Neben einem ganzheitlichen Ansatz, der alle Gesichtspunkte eines optimalen technischen und nachhaltigen Entwurfs berücksichtigt, wurde ein besonderer Schwerpunkt auf den Einfluss der Schubtragfähigkeit von effizienten Verbundmitteln aus Betondübeln mit Bewehrungsstählen gelegt. Für Slim‐Floor‐Träger, die bisher im Eurocode 4 nicht berücksichtigt sind, wurde die Anwendung der bekannten Bemessungsregeln geprüft und zum Teil neue Regeln für die Bemessung insbesondere der Betondübel entwickelt. Mithilfe von Beispielen verschiedener Slim‐Floor‐Lösungen wird die Bemessung im Grenzzustand der Tragfähigkeit und Gebrauchstauglichkeit erläutert und mit einer ganzheitlichen Lebenszyklusanalyse untereinander verglichen.