TATariq Adnan

Tariq Adnan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tariq Adnan has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    NeuroSift for Task-Aware Quality Assurance of Multimedia Data in Remote Parkinson Disease Assessment: Machine Learning Model Development and Validation Study

    by Md Saiful Islam, Sooyong Park, Evelyn Xiaoxiao Ma, Tariq Adnan, Ehsan Hoque

    Background: Automated multimedia analysis of remotely recorded tasks offers a scalable approach to screening and remote monitoring of movement disorders such as Parkinson disease (PD). However, unsupervised recordings often suffer from quality issues that compromise model reliability. General multimedia quality checks may not detect task-specific failures, such as poor hand visibility during finger-tapping, inadequate facial framing during smile tasks, or background noise during speech tasks. Objective: This study aimed to develop and evaluate NeuroSift, a task-aware, interpretable machine learning framework for assessing recording quality and task compliance in home-recorded multimedia data collected for remote PD assessment. Methods: We analyzed 2516 home-recorded audio and video segments from 3 tasks: finger-tapping, facial expression (smile), and speech (pangram utterance). Three experts rated recordings as poor, borderline, or good quality. Task-specific annotation guidelines were developed through iterative review and discussion. We extracted interpretable features aligned with observable quality and compliance criteria and trained task-specific quality classification models. Interrater reliability was evaluated before and after guideline implementation using quadratic weighted Cohen κ (QWK), pairwise agreement, complete agreement, and intraclass correlation. Model performance was evaluated on a held-out test set (labeled using expert consensus) using accuracy, QWK, and ordinal classification accuracy (OCA, an accuracy metric that accounts for the ordered relationship among poor, borderline, and good labels). Feature importance was examined using Shapley additive explanations (SHAP), a method for estimating how individual features contribute to model predictions. Results: The task-specific guidelines significantly improved interrater reliability across all tasks (P<.001)—QWK increased from 0.46 to 0.89 for finger-tapping, from 0.61 to 0.84 for smile, and from 0.64 to 0.90 for speech. For 3-class quality classification, the best-performing models achieved QWK values of 0.71 for finger-tapping, 0.56 for smile, and 0.72 for speech. OCA was 82.1% for finger-tapping, 76.9% for smile, and 89.9% for speech. Most errors were adjacent-class errors, such as classifying poor recordings as borderline, whereas severe errors, such as classifying good recordings as poor, were rare. SHAP analyses identified task-specific sources of quality degradation that aligned with the annotation guidelines. Conclusions: NeuroSift was evaluated as a task-aware quality-classification framework for identifying low-quality or noncompliant multimedia data prior to downstream PD assessment. By combining structured quality guidelines, interpretable features, and explainable machine learning models, NeuroSift supports more transparent and user-correctable remote data collection. Although this study did not test downstream clinical impact, the framework offers a practical approach for quality-aware workflows that rely on user-recorded audio or video. This approach may extend beyond PD assessment to other remote settings, including telehealth, rehabilitation, and digital recruitment. Future studies should evaluate NeuroSift on independent datasets and examine its effects on downstream model performance, fairness, user experience, and workflow integration.

  • Open Access

    Validation of remote multimodal AI screening for Parkinson disease across diverse settings

    by Saiful Islam, Tariq Adnan, Abdelrahman Abdelkader, Zipei Liu, Evelyn Ma, Sooyong Park, Asif Azad, Pai Liu, Meghan Pawlik, Emily Hartman, et al.

    Background: Timely detection of Parkinson’s disease (PD) remains limited by reliance on in-person neurological evaluations that are often costly and geographically inaccessible. To address these barriers, we develop PARK ( Parkinson’s Analysis with Remote Kinetic-tasks ) – a web-based artificial intelligence (AI) tool that screens for PD using short webcam recordings of facial expression, motor, and speech tasks. Methods: Across eight independent studies ( n = 1,865 participants; 670 with PD), participants completed three standardized tasks (smile mimicry, finger tapping, and pangram utterance) via webcam. Task-specific neural networks estimate PD risk and uncertainty, which are integrated through an uncertainty-calibrated fusion model (UFNet). Model performance is evaluated on one internal and two external test sets representing supervised and unsupervised real-world environments. Three movement disorder specialists also reviewed videos from 30 participants to benchmark clinical agreement of the PARK tool. User experience is assessed through structured surveys containing open-ended or multiple-choice questions. Results: PARK achieves accuracies of 80.2–80.6% and AUROC of 0.85-0.87 across all evaluation cohorts, with 83.3–86.5% sensitivity and 71.2–78.4% specificity. Predictive performance remains stable across sex, age, and ethnicity. Agreement with clinician judgments reaches Cohen’s κ = 0.59. Uncertainty estimates reflect diagnostic confidence, and performance declines at high-uncertainty levels. Usability is rated highly (System Usability Scale > 70) in both supervised and unsupervised settings, with low perceived risk and strong user preference for remote screening. Conclusions: PARK demonstrates promising accuracy and favorable user acceptance for remote PD screening, highlighting its potential as an accessible, equitable, and uncertainty-aware tool for neurological assessment when traditional care is challenging to obtain.

  • Open Access

    Neurosift: Quality Assurance for Multimedia Data in Automated Movement Disorder Assessment (Preprint)

    by Saiful Islam, Sooyong Park, Evelyn Ma, Tariq Adnan, Ehsan Hoque

    BACKGROUND Movement disorders affect millions globally, yet access to specialists remains limited. Automated multimedia analysis offers a scalable path for screening and remote monitoring, but unsupervised recordings often suffer from quality issues that compromise model reliability. OBJECTIVE This study presents NeuroSift, a machine learning framework designed to automatically assess recording quality and task compliance in home-based multimedia data collected for movement disorder assessment. METHODS Three experts annotated 2,516 recordings corresponding to three common movement disorder tasks: finger tapping, facial expression, and speech. Based on these annotations, we developed task-specific quality guidelines, designed interpretable features, and trained quality classification models. Inter-rater agreement was evaluated before and after guideline implementation. Interpretable, task-specific features were extracted from each modality, and ordinal classification models were trained to categorize recordings as poor, borderline, or good quality. Model performance was evaluated against expert consensus, and feature importance analyses were conducted to identify common sources of quality degradation. RESULTS The quality guidelines significantly improved inter-rater agreement among experts (???? < 0.001). Across tasks, the quality classification models achieved 77–90% ordinal accuracy against expert consensus when classifying recordings as poor, borderline, or good quality. Feature importance analysis further identifies task-specific failures such as hand visibility, camera angle, or background noise. CONCLUSIONS NeuroSift is intended to strengthen trust in predictive models and support reliable deployment of multimedia-based neurological assessment tools at scale. By identifying low-quality or noncompliant recordings prior to downstream analysis, the framework would enhance the robustness, trustworthiness, and scalability of machine learning-based neurological assessment tools. CLINICALTRIAL None.

  • AI-Enabled Parkinson’s Disease Screening Using Smile Videos

    by Tariq Adnan, Saiful Islam, Sangwu Lee, E.M. Wasifur Rahman Chowdhury, Sutapa Dey Tithi, Kazi Noshin, Rayhanul Islam, Imran Sarker, M. Saifur Rahman, Ruth B. Schneider, et al.


  • Open Access

    Remote AI Screening for Parkinson's Disease: A Multimodal, Cross-Setting Validation Study

    by Saiful Islam, Tariq Adnan, Abdelrahman Abdelkader, Zipei Liu, Evelyn Ma, Sooyong Park, Asif Azad, Pai Liu, Meghan Pawlik, Emily Hartman, et al.

    PARK is a web-based artificial intelligence (AI) tool for remote screening of Parkinson's disease (PD) using video and audio recordings of speech, facial expression, and motor tasks performed via webcam. The study draws on data from 1,865 participants across diverse global demographics and recording environments, including supervised clinical settings and unsupervised home use. On three independent test sets (n=389; 188 with PD), PARK achieved strong predictive performance on classifying individuals with and without PD, with accuracy ranging from 80.2% to 80.6% and area under the receiver operating characteristic curve (AUROC) from 0.85 to 0.87. When evaluated on 30 randomly selected individuals, PARK's assessments were 83.7% accurate and showed high agreement with three movement disorder specialists. The model generalized well across age, sex, and ethnic subgroups and incorporated mechanisms to withhold uncertain predictions to support safe use in unsupervised settings. Usability studies confirmed high participant satisfaction and preference for remote screening. These findings support the potential of PARK as an accessible, scalable, and clinically aligned tool to identify individuals with PD when access to traditional healthcare settings is scarce.


  • Top Cited Papers
    Open Access

    A novel fusion architecture for detecting Parkinson’s Disease using semi-supervised speech embeddings

    by Tariq Adnan, Abdelrahman Abdelkader, Zipei Liu, Ekram Hossain, Sooyong Park, Saiful Islam, Ehsan Hoque

    We introduce a framework for screening Parkinson’s disease (PD) using English pangram utterances. Our dataset includes 1306 participants (392 with PD) from both home and clinical settings, covering diverse demographics (53.2% female). We used deep learning embeddings from Wav2Vec 2.0, WavLM, and ImageBind to capture speech dynamics indicative of PD. Our novel fusion model for PD classification aligns different speech embeddings into a cohesive feature space, outperforming baseline alternatives. In a stratified randomized split, the model achieved an AUROC of 88.9% and an accuracy of 85.7%. Statistical bias analysis showed equitable performance across sex, ethnicity, and age subgroups, with robustness across various disease durations and PD stages. Detailed error analysis revealed higher misclassification rates in specific age ranges for males and females, aligning with clinical insights. External testing yielded AUROCs of 82.1% and 78.4% on two clinical datasets, and an AUROC of 77.4% on an unseen general spontaneous English speech dataset, demonstrating versatility in natural speech analysis and potential for global accessibility and health equity.


  • Open Access

    A User-Centered Framework to Empower People with Parkinson's Disease

    by Wasifur Rahman, Abdelrahman Abdelkader, Sangwu Lee, Phillip Yang, Saiful Islam, Tariq Adnan, Masum Hasan, Ellen Wagner, Sooyong Park, E. Ray Dorsey, et al.

    We present a user-centric validation of a teleneurology platform, assessing its effectiveness in conveying screening information, facilitating user queries, and offering resources to enhance user empowerment. This validation process is implemented in the setting of Parkinson's disease (PD), in collaboration with a neurology department of a major medical center in the USA. Our intention is that with this platform, anyone globally with a webcam and microphone-equipped computer can carry out a series of speech, motor, and facial mimicry tasks. Our validation method demonstrates to users a mock PD risk assessment and provides access to relevant resources, including a chatbot driven by GPT, locations of local neurologists, and actionable and scientifically-backed PD prevention and management recommendations. We share findings from 91 participants (48 with PD, 43 without) aimed at evaluating the user experience and collecting feedback. Our framework was rated positively by 80.85% (standard deviation ± 8.92%) of the participants, and it achieved an above-average 70.42 (standard deviation ± 13.85) System-Usability-Scale (SUS) score. We also conducted a thematic analysis of open-ended feedback to further inform our future work. When given the option to ask any questions to the chatbot, participants typically asked for information about neurologists, screening results, and the community support group. We also provide a roadmap of how the knowledge generated in this paper can be generalized to screening frameworks for other diseases through designing appropriate recording environments, appropriate tasks, and tailored user-interfaces.


  • Use of convolution coding for improving SER performance of OFDM system

    by Tariq Adnan, Ammara Masood

    The paper describes the transmission of BPSK signals in an OFDM system with 64-point IFFT at transmitter and FFT at receiver. The channel over which transmission will take place is ISI Rayleigh fading channel given by 2 tap channel model with path delay [0, 0.5] μs. The sampling frequency of OFDM is to be kept at 20MHz. Cyclic prefix for OFDM is calculated for improving bandwidth efficiency of the system. First, the symbol error rate (SER) of un coded OFDM system is plotted as a function of SNR via simulation in MATLAB and then the result is compared with coded OFDM system's SER plot, where the coding is provided by ½ rate convolution encoder accompanied by viterbi decoder at the receiver side.