NJNatalie Jansen

Natalie Jansen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Natalie Jansen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Feasibility and Acceptability of Oura Ring Sleep Monitoring in Older Adults Admitted From the Emergency Department: Prospective Cohort Study

    by Adrian D Haimovich, Annie Lacourciere, Kerry Palihnich, Sydney Mulqueen, Natalie Jansen, Suzanne M Bertisch, Mara A Schonberg, Aanand D Naik, Sarah D Berry, Edward R Marcantonio, et al.

    Background: Emergency department (ED) boarding exposes admitted older adults to a high-disruption environment. Sleep loss during acute hospitalization is associated with adverse outcomes and may contribute to delirium, yet objective sleep measurement in this setting is difficult. Consumer multisensor wearables may permit low-burden, longitudinal measurement, but the feasibility and acceptability of ring-based monitoring among acutely ill older adults is unknown. Objective: This study aimed to estimate the feasibility and acceptability of Oura Ring Gen 3 sleep monitoring in older adults admitted to the hospital from the ED, and to describe exploratory device-measured and patient-reported sleep outcomes. Methods: We conducted a single-site prospective cohort study from February through March 2025. Patients aged 65 years or older with an inpatient medical bed request were recruited in the ED and asked to wear the ring continuously for up to 4 days or until discharge; monitoring continued after transfer to an inpatient unit from the ED. Participants underwent daily 3-Minute Diagnostic Interview for Confusion Assessment Method-Defined Delirium (3D-CAM) assessments, cognitive testing when not delirious, daily sleep surveys, and an exit survey. Feasibility outcomes were the approached-to-enrolled proportion and the proportion of study completers with wear for more than 75% of the analyzed period. Acceptability was the proportion of exit respondents who disagreed or strongly disagreed that the ring bothered them. Device-estimated sleep duration was normalized to hours per 24 hours, and its association with mean patient-reported sleep quality was assessed using Kendall τ. Results: Of 29 patients approached for consent, 15 enrolled (51.7%, 95% CI 32.5%‐70.6%); 1 withdrew immediately, leaving 14 who completed study procedures. Of these 14 patients, 13 wore the ring for ≥75% of their enrollment period (92.9%, 95% CI 66.1%‐99.8%). Eleven participants completed the exit survey, and 9 reported that the ring was not bothersome (81.8%, 95% CI 48.2%‐97.7%). Among the 13 participants who wore the ring for ≥75% of the analyzed period, median device-estimated sleep was 4.3 (IQR 2.6-7.0) hours per 24 hours. Participants reported good or very good sleep on 9 of 19 surveyed nights (47.4%). Mean sleep quality and device-estimated sleep duration were positively associated among 10 participants with complete paired data (Kendall τ=0.54; P =.04). Conclusions: In this pilot study, we found that sleep monitoring with the Oura Ring Gen 3 was feasible and acceptable to older adults admitted from the ED. These findings support larger studies validating the Oura Ring against polysomnography in hospitalized older adults.

  • Open Access

    An Unusual Cause of Shock in a Trauma Patient with Hemodynamic Instability: A Case Report

    by Natalie Jansen, Christie Lea Fritz

    Introduction: Traumatic injury is the leading cause of death in individuals under 45 years of age, and point-of-care ultrasound (POCUS) has become an essential component of the initial trauma evaluation. However, positive findings on the extended focused assessment with sonography in trauma (eFAST) may be misinterpreted as evidence of an acute surgical emergency, particularly in the context of blunt trauma, underscoring the need for careful clinical correlation. Case Report: We present a case in which a hemodynamically unstable patient had significant free abdominal fluid on eFAST after a fall from standing height. She was ultimately diagnosed with a high-risk pulmonary embolism as the cause of her hemodynamic instability, while the free abdominal fluid was identified as originating both from a ruptured ovarian cyst and from moderate-volume ascites. Conclusion: The eFAST exam is a valuable tool in rapidly identifying intra-abdominal injuries following blunt trauma. However, the presence of free fluid on eFAST may result from causes other than acute intra-abdominal injury requiring surgical intervention. Therefore, emergency physicians should interpret positive findings with clinical judgment and consider the broader clinical context.

  • Open Access

    Cardiac Arrest During a Ferric Derisomaltose Infusion Followed by Complete Heart Block: A Case Report

    by Michael Scott, Natalie Jansen, Leslie A. Bilello

    Introduction: Ferric derisomaltose is the newest available parenteral iron formulation. Studies have demonstrated a good safety profile with improved tolerability compared to alternative parenteral iron formulations. To date there have been no reported acute, life-threatening cardiac events associated with ferric derisomaltose. Case Report: An 86-year-old male who had previously tolerated routine iron infusions received a first dose of ferric derisomaltose at an outpatient infusion clinic. Six minutes into the infusion the patient became unresponsive with no palpable pulse. Return of spontaneous circulation was achieved after two minutes of chest compressions. Electrocardiogram showed complete heart block requiring transcutaneous pacing and vasopressor administration. The patient was transferred to the emergency department for stabilization and then admitted to the cardiac intensive care unit. During admission, the patient received a dual-chamber, permanent pacemaker without complication and was ultimately discharged. Conclusion: It may be reasonable to consider parenteral iron as a toxicological etiology for patients presenting with complete heart block temporally associated with parenteral iron administration, particularly in patients with underlying conduction abnormalities.

  • Men's Migration and Women's Health in Rural Sub-Saharan Africa: The Role of Migration's Economic Returns and Spousal Communication

    by Natalie Jansen, Victor Agadjanian

    In this study, we investigate the association between men's labor migration and changes in their non-migrating wives’ self-rated health (SRH) over time using longitudinal data from rural Mozambique. In addition to comparing wives of non-migrants and wives of migrants, we account for variation in the economic impact of migration and in migrants’ phone communication with their spouses. We find that migrants’ wives are significantly less likely to report low SRH, compared to non-migrants’ wives, net of other factors. However, this net advantage is concentrated among migrants’ wives who receive frequent remittances and who report that their households’ conditions have improved thanks to husband's migration. We also find that women who engage in frequent phone communication with their migrant husbands have decreased likelihoods of low SRH, compared to migrants’ wives who do not communicate with their husbands during their migration and to women married to non-migrants, regardless of other characteristics. We interpret these findings within the context of multifaceted gendered implications of men's migration for left-behind women's health and wellbeing.