Wenhua Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wenhua Yu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Cong Liu
Department of Intelligent Manufacturing, Wuyi University, China
1 shared publication - Da Chen
Department of Microelectronic Science and Engineering, School of Physical Science and Technology, Ningbo University, Ningbo 315211, PR China
1 shared publication - Dexin Zhen
Department of Intelligent Manufacturing, Wuyi University, China
1 shared publication Jilong Ma
Shandong University of Science and Technology
1 shared publication- Shaotian Wang
Collaborative Innovation Center of Memristive, Computing Application (CICMCA), Qilu Institute of Technology, Jinan 250200, P. R. China
1 shared publication - Shuren Song
State Key Laboratory of ASIC and System, School of Microelectronics, Fudan University, Shanghai, People's Republic of China
1 shared publication
Latest Publications
- Open Access
- 27 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 92-99
An Efficient Helmet Wearing Detection Method Based On YOLOv7-Tiny
- 27 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 92-99
Open AccessAn Efficient Helmet Wearing Detection Method Based On YOLOv7-Tiny
- 20 December 2017
- Published by Springer Nature in Applied Physics A
- Vol. 124 (1) , 56
ZnO piezoelectric film resonator modified with multi-walled carbon nanotubes/polyethyleneimine bilayer for the detection of trace formaldehyde
- 20 December 2017
- Published by Springer Nature in Applied Physics A
- Vol. 124 (1) , 56
ZnO piezoelectric film resonator modified with multi-walled carbon nanotubes/polyethyleneimine bilayer for the detection of trace formaldehyde
- 1 July 2006
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 77 (7) , 076102
Influence of insulation coating on thermal conductivity measurement by transient hot-wire method
The transient hot-wire method is widely used to determine the thermal conductivity of various media. It has been improved through the addition of an insulation coating to the wire. However, this coating could affect the accuracy of the thermal conductivity measurement. The temperature rise for the insulation-coated wire was calculated as a function of time by a Laplace transformation along with the expansion method outlined by Carslaw and Jaeger [Conduction of Heat in Solids (Oxford University Press, Oxford, 1959)]. The results of numerical simulations and experimental tests show that, for most engineering applications, the relative measurement errors of the thermal conductivity caused by the insulation coating are very small if the slopes of the temperature rise-logarithmic time diagrams are calculated for large time values. No correction to the insulation coating is necessary even for the conditions that the insulation coating thickness is comparable to the wire radius, and that the thermal conductivity of the insulation coating is lower than that of the measured medium.
- 1 July 2006
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 77 (7) , 076102
Influence of insulation coating on thermal conductivity measurement by transient hot-wire method
The transient hot-wire method is widely used to determine the thermal conductivity of various media. It has been improved through the addition of an insulation coating to the wire. However, this coating could affect the accuracy of the thermal conductivity measurement. The temperature rise for the insulation-coated wire was calculated as a function of time by a Laplace transformation along with the expansion method outlined by Carslaw and Jaeger [Conduction of Heat in Solids (Oxford University Press, Oxford, 1959)]. The results of numerical simulations and experimental tests show that, for most engineering applications, the relative measurement errors of the thermal conductivity caused by the insulation coating are very small if the slopes of the temperature rise-logarithmic time diagrams are calculated for large time values. No correction to the insulation coating is necessary even for the conditions that the insulation coating thickness is comparable to the wire radius, and that the thermal conductivity of the insulation coating is lower than that of the measured medium.