Wee Sen Lim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wee Sen Lim has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Prayook Jatesiktat
Rehabilitation Research Institute of Singapore, Nanyang Technological University, Singapore
2 shared publications - Wei Tech Ang
School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
2 shared publications - Denny Tjiauw Tjoen Lie
Singapore General Hospital
1 shared publication - Guan Ming Lim
Rehabilitation Research Institute of Singapore, Nanyang Technological University, Singapore
1 shared publication - Jun Liang Lau
Department of Orthopedics, Singapore General Hospital, Singapore 169856, Singapore
1 shared publication - Siaw Meng Chou
School of Mechanical & Aerospace Engineering, Nanyang Technological University, Singapore, Singapore
1 shared publication
Latest Publications
- 9 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (9) , 6186-6199
Anatomical-Marker-Driven 3D Markerless Human Motion Capture
Marker-based motion capture (mocap) is a conventional method used in biomechanics research to precisely analyze human movement. However, the time-consuming marker placement process and extensive post-processing limit its wider adoption. Therefore, markerless mocap systems that use deep learning to estimate 2D keypoint from images have emerged as a promising alternative, but annotation errors in training datasets used by deep learning models can affect estimation accuracy. To improve the precision of 2D keypoint annotation, we present a method that uses anatomical landmarks based on marker-based mocap. Specifically, we use multiple RGB cameras synchronized and calibrated with a marker-based mocap system to create a high-quality dataset (RRIS40) of images annotated with surface anatomical landmarks. A deep neural network is then trained to estimate these 2D anatomical landmarks and a ray-distance-based triangulation is used to calculate the 3D marker positions. We conducted extensive evaluations on our RRIS40 test set, which consists of 10 subjects performing various movements. Compared against a marker-based system, our method achieves a mean Euclidean error of 13.23 mm in 3D marker position, which is comparable to the precision of marker placement itself. By learning directly to predict anatomical keypoints from images, our method outperforms OpenCap's augmentation of 3D anatomical landmarks from triangulated wild keypoints. This highlights the potential of facilitating wider integration of markerless mocap into biomechanics research. The RRIS40 test set is made publicly available for research purposes at koonyook.github.io/rris40 .
- 9 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (9) , 6186-6199
Anatomical-Marker-Driven 3D Markerless Human Motion Capture
Marker-based motion capture (mocap) is a conventional method used in biomechanics research to precisely analyze human movement. However, the time-consuming marker placement process and extensive post-processing limit its wider adoption. Therefore, markerless mocap systems that use deep learning to estimate 2D keypoint from images have emerged as a promising alternative, but annotation errors in training datasets used by deep learning models can affect estimation accuracy. To improve the precision of 2D keypoint annotation, we present a method that uses anatomical landmarks based on marker-based mocap. Specifically, we use multiple RGB cameras synchronized and calibrated with a marker-based mocap system to create a high-quality dataset (RRIS40) of images annotated with surface anatomical landmarks. A deep neural network is then trained to estimate these 2D anatomical landmarks and a ray-distance-based triangulation is used to calculate the 3D marker positions. We conducted extensive evaluations on our RRIS40 test set, which consists of 10 subjects performing various movements. Compared against a marker-based system, our method achieves a mean Euclidean error of 13.23 mm in 3D marker position, which is comparable to the precision of marker placement itself. By learning directly to predict anatomical keypoints from images, our method outperforms OpenCap's augmentation of 3D anatomical landmarks from triangulated wild keypoints. This highlights the potential of facilitating wider integration of markerless mocap into biomechanics research. The RRIS40 test set is made publicly available for research purposes at koonyook.github.io/rris40 .
- Open Access
- 8 August 2023
- Published by Association for Computing Machinery (ACM)
- p. 47-51
Markerless Mocap for Active Shoulder Range of Motion Measurement in a Clinic Room: a Pilot Trial
This paper presents a pilot study that uses a markerless motion capture system to measure active shoulder joint range of motion in a clinic room. The measurements from this automated method are compared with manual measurements done by a clinician using a goniometer. All the parameters from both methods are positively correlated. The root-mean-square differences from the comparisons are in the range of 7.21° – 15.87° depending on the type of angles. With a careful protocol design and execution, the markerless motion capture system can potentially be used as an objective shoulder range of motion assessment tool in clinical practice.
- 8 August 2023
- Published by Association for Computing Machinery (ACM)
- p. 47-51
Open AccessMarkerless Mocap for Active Shoulder Range of Motion Measurement in a Clinic Room: a Pilot Trial
This paper presents a pilot study that uses a markerless motion capture system to measure active shoulder joint range of motion in a clinic room. The measurements from this automated method are compared with manual measurements done by a clinician using a goniometer. All the parameters from both methods are positively correlated. The root-mean-square differences from the comparisons are in the range of 7.21° – 15.87° depending on the type of angles. With a careful protocol design and execution, the markerless motion capture system can potentially be used as an objective shoulder range of motion assessment tool in clinical practice.