Yang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yang Wang has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
Xiaolin Meng
School of Electronic Information and Electrical Engineering Shanghai Jiao Tong University Shanghai China
4 shared publicationsRunqiu Huang
3 shared publicationsDi Dong
2 shared publicationsGuolin Ma
2 shared publications- Jun Wang
Department of Critical Care Medicine, The First Affiliated Hospital of Soochow University
2 shared publications Lu Cao
2 shared publications
Latest Publications
- Open Access
- 23 June 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (7) , e70665
Personalized eye protection for head CT organ‐based tube current modulation: A deep learning approach to derive 3D eyeball models from a single‐view topogram
Background: The lens of the eye is highly radiosensitive, yet personalized shielding during head CT remains challenging due to the lack of a rapid, pre‐scan localization method. Purpose: To develop and validate a deep learning solution that enables automated, patient‐specific eye protection by generating a precise 3D eyeball model directly from a single‐view topogram. Methods: Our two‐stage approach combines an advanced data simulation pipeline—which generates realistic training topograms from digitally reconstructed radiographs (DRRs) using a table‐movement‐aware model and CycleGAN‐based stylization—with a dedicated generative network (EyeGen‐Net). The model was trained on 400 synthetic and validated on 100 real clinical samples. Results: EyeGen‐Net achieved a Dice Similarity Coefficient of 0.79 ± 0.08, a Hausdorff Distance of 5.40 ± 1.57 mm, and an Average Surface Distance of 1.84 ± 0.65 mm against expert segmentations. Crucially, phantom validation demonstrated that the derived 3D model facilitates organ‐based tube current modulation (OBTCM), yielding an approximate 30% reduction in lens dose across different scanning modes without compromising diagnostic image quality. Conclusions: This work provides a practical, automated pathway for implementing personalized radioprotection in routine head CT, aligning with the ALARA (As Low As Reasonably Achievable) principle.
- 23 June 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (7) , e70665
Open AccessPersonalized eye protection for head CT organ‐based tube current modulation: A deep learning approach to derive 3D eyeball models from a single‐view topogram
Background: The lens of the eye is highly radiosensitive, yet personalized shielding during head CT remains challenging due to the lack of a rapid, pre‐scan localization method. Purpose: To develop and validate a deep learning solution that enables automated, patient‐specific eye protection by generating a precise 3D eyeball model directly from a single‐view topogram. Methods: Our two‐stage approach combines an advanced data simulation pipeline—which generates realistic training topograms from digitally reconstructed radiographs (DRRs) using a table‐movement‐aware model and CycleGAN‐based stylization—with a dedicated generative network (EyeGen‐Net). The model was trained on 400 synthetic and validated on 100 real clinical samples. Results: EyeGen‐Net achieved a Dice Similarity Coefficient of 0.79 ± 0.08, a Hausdorff Distance of 5.40 ± 1.57 mm, and an Average Surface Distance of 1.84 ± 0.65 mm against expert segmentations. Crucially, phantom validation demonstrated that the derived 3D model facilitates organ‐based tube current modulation (OBTCM), yielding an approximate 30% reduction in lens dose across different scanning modes without compromising diagnostic image quality. Conclusions: This work provides a practical, automated pathway for implementing personalized radioprotection in routine head CT, aligning with the ALARA (As Low As Reasonably Achievable) principle.
- Open Access
- 22 April 2026
- Published by Springer Nature in European Journal of Medical Research
- Vol. 31 (1)
Non-invasive prediction of EGFR and EGFR/TP53 co-mutations in lung adenocarcinoma from chest CT via pre-trained 3D CNN models
- 22 April 2026
- Published by Springer Nature in European Journal of Medical Research
- Vol. 31 (1)
Open AccessNon-invasive prediction of EGFR and EGFR/TP53 co-mutations in lung adenocarcinoma from chest CT via pre-trained 3D CNN models
- Open Access
- 1 April 2026
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 18 (4) , 397
Risk stratification of PD-L1 expression in non-small cell lung cancer: a predictive model for prognosis
Background: Immune checkpoint inhibitors (ICIs) have become the standard of care for non-small cell lung cancer (NSCLC) patients with programmed cell death ligand-1 (PD-L1) expression ≥1%. However, not all patients benefit equally from this treatment. This study develops a predictive model for risk stratification in NSCLC patients, integrating clinical, radiological, genomic, and PD-L1 expression data to enhance immunotherapy outcomes. Methods: We conducted a multicenter, retrospective cohort study of NSCLC patients treated with immunotherapy from January 2018 to June 2024. The primary endpoint was overall survival (OS), and secondary endpoints included progression-free survival (PFS). We constructed a prognostic nomogram using Kaplan-Meier survival analysis and multivariable Cox regression to identify key prognostic factors. Model performance was rigorously validated internally via C-index, time-dependent receiver operating characteristic (time-ROC) curves, calibration plots, 1,000-replicate bootstrap resampling, and decision curve analysis (DCA)—and patients were stratified into distinct risk groups. Results: PD-L1 expression ≥1% was associated with significantly improved OS (563 vs. 421 days, P=0.004). The multivariable Cox regression model included sex, histologic subtype, stage, Eastern Cooperative Oncology Group (ECOG) performance status (PS), and mutations in BRAF, KRAS, and TP53. The model demonstrated good discrimination with area under the ROC curve values of 0.723 [95% confidence interval (CI): 0.671–0.775] for 1-year OS, 0.789 (95% CI: 0.716–0.862) for 3-year OS, and 0.688 (95% CI: 0.586–0.790) for 5-year OS predictions, respectively. Calibration plots indicated good agreement between predicted and observed 1-year OS probabilities. DCA demonstrated that the model provides clinical benefit at a range of decision thresholds for 1-year OS. Conclusions: The prognostic model constructed in this study has excellent short-term predictive efficacy and clinical practicability. It can effectively stratify the prognosis risks of NSCLC patients after ICIs treatment, providing a convenient quantitative reference for clinical decision-making.
- 1 April 2026
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 18 (4) , 397
Open AccessRisk stratification of PD-L1 expression in non-small cell lung cancer: a predictive model for prognosis
Background: Immune checkpoint inhibitors (ICIs) have become the standard of care for non-small cell lung cancer (NSCLC) patients with programmed cell death ligand-1 (PD-L1) expression ≥1%. However, not all patients benefit equally from this treatment. This study develops a predictive model for risk stratification in NSCLC patients, integrating clinical, radiological, genomic, and PD-L1 expression data to enhance immunotherapy outcomes. Methods: We conducted a multicenter, retrospective cohort study of NSCLC patients treated with immunotherapy from January 2018 to June 2024. The primary endpoint was overall survival (OS), and secondary endpoints included progression-free survival (PFS). We constructed a prognostic nomogram using Kaplan-Meier survival analysis and multivariable Cox regression to identify key prognostic factors. Model performance was rigorously validated internally via C-index, time-dependent receiver operating characteristic (time-ROC) curves, calibration plots, 1,000-replicate bootstrap resampling, and decision curve analysis (DCA)—and patients were stratified into distinct risk groups. Results: PD-L1 expression ≥1% was associated with significantly improved OS (563 vs. 421 days, P=0.004). The multivariable Cox regression model included sex, histologic subtype, stage, Eastern Cooperative Oncology Group (ECOG) performance status (PS), and mutations in BRAF, KRAS, and TP53. The model demonstrated good discrimination with area under the ROC curve values of 0.723 [95% confidence interval (CI): 0.671–0.775] for 1-year OS, 0.789 (95% CI: 0.716–0.862) for 3-year OS, and 0.688 (95% CI: 0.586–0.790) for 5-year OS predictions, respectively. Calibration plots indicated good agreement between predicted and observed 1-year OS probabilities. DCA demonstrated that the model provides clinical benefit at a range of decision thresholds for 1-year OS. Conclusions: The prognostic model constructed in this study has excellent short-term predictive efficacy and clinical practicability. It can effectively stratify the prognosis risks of NSCLC patients after ICIs treatment, providing a convenient quantitative reference for clinical decision-making.
- Open Access
- 1 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Research
- Vol. 9
Clinical Application of Deep Learning for Spine MRI Interpretation: A Multicenter Evaluation of Artificial-Intelligence-Assisted versus Manual Reading on Diagnostic Agreement with the Reference Standard
Lumbar spine diseases substantially impact the patients’ quality of life, necessitating accurate and efficient diagnostic tools. This study presents Lumbar VNet Pro (LVP), the first real-time artificial-intelligence (AI)-assisted system embedded within MRI hardware for lumbar spine analysis, integrating deep learning with MRI. LVP was trained on 2,453 MRI datasets and validated both internally and externally across multiple centers. During the training (1,848 MRI datasets) and validation (605 MRI datasets), LVP exhibited outstanding performance in localization (Dice = 0.93), segmentation (Dice = 0.92), labeling (identification rate = 0.90), and timeliness (average inference time = 1.1 s). Following the successful construction of LVP, we conducted comprehensive testing through both internal and external multicenter evaluations. Internal testing involving 100 patients indicated that the recognition accuracy of LVP was as high as 100%, and the consistency between the LVP assessment and the manual assessment using the gold standard reached 97%. In external testing involving 1,522 patients, LVP’s diagnostic performance was compared to those of manual and human–machine-assisted methods. The AI-assisted approaches demonstrated better performance across multiple spinal pathologies, including lumbar disc herniation, spinal canal stenosis, and lateral recess stenosis, with area under the receiver operating characteristic curve values >0.95 for deep learning/human–machine approaches and >0.90 for the fully manual approach. The real-time integration of LVP with MRI scanning improved positioning accuracy and reduced interobserver variability, supporting its potential as an adjunct tool for enhancing MRI-based spine diagnostics. However, further studies are warranted to assess its generalizability across diverse clinical settings.
- 1 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Research
- Vol. 9
Open AccessClinical Application of Deep Learning for Spine MRI Interpretation: A Multicenter Evaluation of Artificial-Intelligence-Assisted versus Manual Reading on Diagnostic Agreement with the Reference Standard
Lumbar spine diseases substantially impact the patients’ quality of life, necessitating accurate and efficient diagnostic tools. This study presents Lumbar VNet Pro (LVP), the first real-time artificial-intelligence (AI)-assisted system embedded within MRI hardware for lumbar spine analysis, integrating deep learning with MRI. LVP was trained on 2,453 MRI datasets and validated both internally and externally across multiple centers. During the training (1,848 MRI datasets) and validation (605 MRI datasets), LVP exhibited outstanding performance in localization (Dice = 0.93), segmentation (Dice = 0.92), labeling (identification rate = 0.90), and timeliness (average inference time = 1.1 s). Following the successful construction of LVP, we conducted comprehensive testing through both internal and external multicenter evaluations. Internal testing involving 100 patients indicated that the recognition accuracy of LVP was as high as 100%, and the consistency between the LVP assessment and the manual assessment using the gold standard reached 97%. In external testing involving 1,522 patients, LVP’s diagnostic performance was compared to those of manual and human–machine-assisted methods. The AI-assisted approaches demonstrated better performance across multiple spinal pathologies, including lumbar disc herniation, spinal canal stenosis, and lateral recess stenosis, with area under the receiver operating characteristic curve values >0.95 for deep learning/human–machine approaches and >0.90 for the fully manual approach. The real-time integration of LVP with MRI scanning improved positioning accuracy and reduced interobserver variability, supporting its potential as an adjunct tool for enhancing MRI-based spine diagnostics. However, further studies are warranted to assess its generalizability across diverse clinical settings.
- 16 October 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 39 (4) , 1-9
Personalized CT Protocol Recommendation via Large Language Model: Enabling Fully Automated CT Scanning Workflows
Manual CT protocol selection persists as a time-intensive and error-prone bottleneck in radiology workflows, impeding the realization of fully automated scanning pipelines. To overcome this limitation, we developed a Large Language Model Retrieval-Augmented Generation (LLM-RAG) framework for personalized CT protocol recommendation. This system constructs a protocol knowledge base from historical examination records to deliver institutionally tailored, precision recommendations aligned with clinical preferences. Our system demonstrated compelling performance (min: 88.60% precision, 89.34% recall, 88.08% F1, 96.09% accuracy), with key findings revealing: (1) task-specific parity between Qwen and DeepSeek models at equivalent scales (max Δ = 1.41% at 32B); (2) positive scaling laws where larger models boost accuracy (e.g., DeepSeek 7B → 32B: + 1.55%); and (3) linear GPU memory-cost scaling (7B:25 GB → 32B:95 GB), defining clinical deployment constraints. Error analysis of 225 discordant cases identified three primary patterns: over-recommendation (52.44%), unsuitable recommendation (27.56%), and clinically equivalent choices (20%). Critically, the framework achieves clinically viable accuracy without model retraining requirements—a pivotal advantage enabling significant utility in streamlining scanning operations and accelerating imaging workflow automation.
- 16 October 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 39 (4) , 1-9
Personalized CT Protocol Recommendation via Large Language Model: Enabling Fully Automated CT Scanning Workflows
Manual CT protocol selection persists as a time-intensive and error-prone bottleneck in radiology workflows, impeding the realization of fully automated scanning pipelines. To overcome this limitation, we developed a Large Language Model Retrieval-Augmented Generation (LLM-RAG) framework for personalized CT protocol recommendation. This system constructs a protocol knowledge base from historical examination records to deliver institutionally tailored, precision recommendations aligned with clinical preferences. Our system demonstrated compelling performance (min: 88.60% precision, 89.34% recall, 88.08% F1, 96.09% accuracy), with key findings revealing: (1) task-specific parity between Qwen and DeepSeek models at equivalent scales (max Δ = 1.41% at 32B); (2) positive scaling laws where larger models boost accuracy (e.g., DeepSeek 7B → 32B: + 1.55%); and (3) linear GPU memory-cost scaling (7B:25 GB → 32B:95 GB), defining clinical deployment constraints. Error analysis of 225 discordant cases identified three primary patterns: over-recommendation (52.44%), unsuitable recommendation (27.56%), and clinically equivalent choices (20%). Critically, the framework achieves clinically viable accuracy without model retraining requirements—a pivotal advantage enabling significant utility in streamlining scanning operations and accelerating imaging workflow automation.
- 25 January 2025
- Published by Wiley in Interdisciplinary Medicine
- Vol. 3 (1)
Artificial Intelligence‐Driven Change Redefining Radiology Through Interdisciplinary Innovation (1/2025)
- 25 January 2025
- Published by Wiley in Interdisciplinary Medicine
- Vol. 3 (1)
Artificial Intelligence‐Driven Change Redefining Radiology Through Interdisciplinary Innovation (1/2025)
- Open Access
- 13 January 2025
- Published by Ivyspring International Publisher in International Journal of Biological Sciences
- Vol. 21 (3) , 1174-1186
GATA6 Facilitates Progression of Intervertebral Disc Degeneration by Regulating Ferroptosis via Targeting TLR2/AKR1C3
This study explored the role of ferroptosis in intervertebral disc degeneration (IVDD), and identified GATA6 as a key regulator of this process. A ferroptosis-related gene risk coefficient model was constructed using differential gene expression analysis of the GSE70362 dataset. The analysis identified GATA6 as a significant factor in IVDD progression. GATA6 was shown to promote ferroptosis in nucleus pulposus cells (NPCs) by regulating the expression of AKR1C3 through the TLR2 pathway. In vitro and in vivo experiments demonstrated that GATA6 knockdown reduced ferroptosis, improved cell viability, and mitigated extracellular matrix degradation, whereas GATA6 overexpression exacerbated these processes. Furthermore, AKR1C3 was found to be crucial for GATA6-mediated ferroptosis, and modulation of the TLR2-AKR1C3 axis significantly impacted the degeneration of NPCs. These findings suggest that targeting GATA6 and its downstream TLR2-AKR1C3 pathway may provide new therapeutic approaches for IVDD.
- 13 January 2025
- Published by Ivyspring International Publisher in International Journal of Biological Sciences
- Vol. 21 (3) , 1174-1186
Open AccessGATA6 Facilitates Progression of Intervertebral Disc Degeneration by Regulating Ferroptosis via Targeting TLR2/AKR1C3
This study explored the role of ferroptosis in intervertebral disc degeneration (IVDD), and identified GATA6 as a key regulator of this process. A ferroptosis-related gene risk coefficient model was constructed using differential gene expression analysis of the GSE70362 dataset. The analysis identified GATA6 as a significant factor in IVDD progression. GATA6 was shown to promote ferroptosis in nucleus pulposus cells (NPCs) by regulating the expression of AKR1C3 through the TLR2 pathway. In vitro and in vivo experiments demonstrated that GATA6 knockdown reduced ferroptosis, improved cell viability, and mitigated extracellular matrix degradation, whereas GATA6 overexpression exacerbated these processes. Furthermore, AKR1C3 was found to be crucial for GATA6-mediated ferroptosis, and modulation of the TLR2-AKR1C3 axis significantly impacted the degeneration of NPCs. These findings suggest that targeting GATA6 and its downstream TLR2-AKR1C3 pathway may provide new therapeutic approaches for IVDD.
- Open Access
- 6 January 2025
- Published by Wiley in Interdisciplinary Medicine
- Vol. 3 (1)
Artificial intelligence‐driven change redefining radiology through interdisciplinary innovation
Artificial intelligence (AI) is rapidly advancing, yet its applications in radiology remain relatively nascent. From a spatiotemporal perspective, this review examines the forces driving AI development and its integration with medicine and radiology, with a particular focus on advancements addressing major diseases that significantly threaten human health. Temporally, the advent of foundational model architectures, combined with the underlying drivers of AI development, is accelerating the progress of AI interventions and their practical applications. Spatially, the discussion explores the potential of evolving AI methodologies to strengthen interdisciplinary applications within medicine, emphasizing the integration of AI with the four critical points of the imaging process, as well as its application in disease management, including the emergence of commercial AI products. Additionally, the current utilization of deep learning is reviewed, and future advancements through multimodal foundation models and Generative Pre‐trained Transformer are anticipated.
- 6 January 2025
- Published by Wiley in Interdisciplinary Medicine
- Vol. 3 (1)
Open AccessArtificial intelligence‐driven change redefining radiology through interdisciplinary innovation
Artificial intelligence (AI) is rapidly advancing, yet its applications in radiology remain relatively nascent. From a spatiotemporal perspective, this review examines the forces driving AI development and its integration with medicine and radiology, with a particular focus on advancements addressing major diseases that significantly threaten human health. Temporally, the advent of foundational model architectures, combined with the underlying drivers of AI development, is accelerating the progress of AI interventions and their practical applications. Spatially, the discussion explores the potential of evolving AI methodologies to strengthen interdisciplinary applications within medicine, emphasizing the integration of AI with the four critical points of the imaging process, as well as its application in disease management, including the emergence of commercial AI products. Additionally, the current utilization of deep learning is reviewed, and future advancements through multimodal foundation models and Generative Pre‐trained Transformer are anticipated.
- 5 February 2024
- Published by Elsevier in Journal of Thoracic Oncology
- Vol. 19 (2) , 344-345
An Error in Modeling and the Selection of Independent Radiomics Variables Need Caution
- 5 February 2024
- Published by Elsevier in Journal of Thoracic Oncology
- Vol. 19 (2) , 344-345
An Error in Modeling and the Selection of Independent Radiomics Variables Need Caution
- Open Access
- 3 March 2022
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 29 (3) , 243-250
Predisposing factors for the deformation of parent artery of anterior circulation saccular aneurysm after stent-assisted embolization: A retrospective cohort study
Background: It has been previously reported in several studies that deformation of parent artery (DPA) occurs after stent-assisted coil embolization (SACE) for intracranial aneurysms (IAs). Objective: To investigate the predisposing factors of stent-induced DPA, as well as its effect on the follow-up of aneurysm embolization. Methods: Clinical and imaging data were collected from 198 patients (201 aneurysms). Angles of the stent-covered parental artery were measured before treatment and during follow-up. Cases in which the angle had changed more than 5 degrees, were defined as DPA. The related factors of DPA were analyzed. The relation between DPA and follow-up results was also studied. Results: Univariate analysis revealed that sex (p = 0.014), age (p = 0.017), aneurysm location (p < 0.001), stent type (p < 0.001), aneurysm size (p = 0.019), and pretreatment angle (p = 0.002) correlated with DPA. On the other hand, multivariate analysis revealed that aneurysms located in the anterior communicating artery (ACOA) (OR = 4.559, p = 0.013) and middle cerebral artery (MCA) (OR = 9.474, p < 0.001) were independent predisposing factors for DPA after stent implantation, whereas a braided stent (OR = 0.221, p = 0.030), flow diverter (FD) device (OR = 0.100, p = 0.028) were negative factors to develop DPA. The complete occlusion rate in the DPA group was higher (p = 0.035) than in the non-DPA group. Conclusions: Aneurysms located in ACOA and MCA are more prone to DPA after SACE than aneurysms at other locations in the anterior circulation, braided stents and FD devices do not predispose to induce vascular deformation. DPA may be beneficial for the long-term cure of IAs after SACE.
- 3 March 2022
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 29 (3) , 243-250
Open AccessPredisposing factors for the deformation of parent artery of anterior circulation saccular aneurysm after stent-assisted embolization: A retrospective cohort study
Background: It has been previously reported in several studies that deformation of parent artery (DPA) occurs after stent-assisted coil embolization (SACE) for intracranial aneurysms (IAs). Objective: To investigate the predisposing factors of stent-induced DPA, as well as its effect on the follow-up of aneurysm embolization. Methods: Clinical and imaging data were collected from 198 patients (201 aneurysms). Angles of the stent-covered parental artery were measured before treatment and during follow-up. Cases in which the angle had changed more than 5 degrees, were defined as DPA. The related factors of DPA were analyzed. The relation between DPA and follow-up results was also studied. Results: Univariate analysis revealed that sex (p = 0.014), age (p = 0.017), aneurysm location (p < 0.001), stent type (p < 0.001), aneurysm size (p = 0.019), and pretreatment angle (p = 0.002) correlated with DPA. On the other hand, multivariate analysis revealed that aneurysms located in the anterior communicating artery (ACOA) (OR = 4.559, p = 0.013) and middle cerebral artery (MCA) (OR = 9.474, p < 0.001) were independent predisposing factors for DPA after stent implantation, whereas a braided stent (OR = 0.221, p = 0.030), flow diverter (FD) device (OR = 0.100, p = 0.028) were negative factors to develop DPA. The complete occlusion rate in the DPA group was higher (p = 0.035) than in the non-DPA group. Conclusions: Aneurysms located in ACOA and MCA are more prone to DPA after SACE than aneurysms at other locations in the anterior circulation, braided stents and FD devices do not predispose to induce vascular deformation. DPA may be beneficial for the long-term cure of IAs after SACE.