Andreea Liliana Cocosila
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andreea Liliana Cocosila has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Alina Robu
Faculty of Materials Science and Engineering, National University of Science and Technology Politehnica, 060042 Bucharest, Romania
1 shared publication - Ana-Iulia Bita
Faculty of Material Science and Engineering, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, District 6, 060042 Bucharest, Romania
1 shared publication - Anca Porumb
Dental Medicine Department, University of Oradea, 410068 Oradea, Romania
1 shared publication - Armin Ettl
Karl Landsteiner University of Health Sciences, Krems, Austria
1 shared publication - Aurora Antoniac
Faculty of Material Science and Engineering, National University of Science and Technology Politehnica Bucharest, 313 Splaiul Independentei, District 6, 060042 Bucharest, Romania
1 shared publication - Barbara Daxer
Karl Landsteiner University of Health Sciences, Krems, Austria
1 shared publication
Latest Publications
- Open Access
Aetiology, Diagnosis and Treatment of Arterial Occlusions of the Retina—A Narrative Review
Arterial occlusions of the retina are potentially sight-threatening diseases which often result in profound visual loss. The aim of this narrative review is to provide an overview of the aetiology, discuss major risk factors, describe the management and systemic assessments and evaluate existing therapies. For this review, an extensive literature search in PubMed was performed. Emboli from the heart or the carotid arteries can cause ophthalmic artery occlusion (OAO), central retinal artery occlusion (CRAO) and branch retinal artery occlusion (BRAO). Most patients with arterial occlusions have vascular risk factors such as arterial hypertension, hyperhomocysteinaemia, carotid stenosis and atrial fibrillation, which also increase the risk of cerebral stroke and myocardial infarction. Therapies such as ocular massage, thrombolysis and anterior chamber paracentesis have been suggested but are still equivocal. However, it is evident that retinal artery occlusion should be immediately treated and accompanied by interdisciplinary collaboration, since early diagnosis and the proper treatment of possible risk factors are important to reduce the risk of further damage, recurrences, other vascular diseases and mortality.
Open AccessAetiology, Diagnosis and Treatment of Arterial Occlusions of the Retina—A Narrative Review
Arterial occlusions of the retina are potentially sight-threatening diseases which often result in profound visual loss. The aim of this narrative review is to provide an overview of the aetiology, discuss major risk factors, describe the management and systemic assessments and evaluate existing therapies. For this review, an extensive literature search in PubMed was performed. Emboli from the heart or the carotid arteries can cause ophthalmic artery occlusion (OAO), central retinal artery occlusion (CRAO) and branch retinal artery occlusion (BRAO). Most patients with arterial occlusions have vascular risk factors such as arterial hypertension, hyperhomocysteinaemia, carotid stenosis and atrial fibrillation, which also increase the risk of cerebral stroke and myocardial infarction. Therapies such as ocular massage, thrombolysis and anterior chamber paracentesis have been suggested but are still equivocal. However, it is evident that retinal artery occlusion should be immediately treated and accompanied by interdisciplinary collaboration, since early diagnosis and the proper treatment of possible risk factors are important to reduce the risk of further damage, recurrences, other vascular diseases and mortality.
- Open Access
Mechanical and Computational Fluid Dynamic Models for Magnesium-Based Implants
Today, mechanical properties and fluid flow dynamic analysis are considered to be two of the most important steps in implant design for bone tissue engineering. The mechanical behavior is characterized by Young’s modulus, which must have a value close to that of the human bone, while from the fluid dynamics point of view, the implant permeability and wall shear stress are two parameters directly linked to cell growth, adhesion, and proliferation. In this study, we proposed two simple geometries with a three-dimensional pore network dedicated to a manufacturing route based on a titanium wire waving procedure used as an intermediary step for Mg-based implant fabrication. Implant deformation under different static loads, von Mises stresses, and safety factors were investigated using finite element analysis. The implant permeability was computed based on Darcy’s law following computational fluid dynamic simulations and, based on the pressure drop, was numerically estimated. It was concluded that both models exhibited a permeability close to the human trabecular bone and reduced wall shear stresses within the biological range. As a general finding, the proposed geometries could be useful in orthopedics for bone defect treatment based on numerical analyses because they mimic the trabecular bone properties.
Open AccessMechanical and Computational Fluid Dynamic Models for Magnesium-Based Implants
Today, mechanical properties and fluid flow dynamic analysis are considered to be two of the most important steps in implant design for bone tissue engineering. The mechanical behavior is characterized by Young’s modulus, which must have a value close to that of the human bone, while from the fluid dynamics point of view, the implant permeability and wall shear stress are two parameters directly linked to cell growth, adhesion, and proliferation. In this study, we proposed two simple geometries with a three-dimensional pore network dedicated to a manufacturing route based on a titanium wire waving procedure used as an intermediary step for Mg-based implant fabrication. Implant deformation under different static loads, von Mises stresses, and safety factors were investigated using finite element analysis. The implant permeability was computed based on Darcy’s law following computational fluid dynamic simulations and, based on the pressure drop, was numerically estimated. It was concluded that both models exhibited a permeability close to the human trabecular bone and reduced wall shear stresses within the biological range. As a general finding, the proposed geometries could be useful in orthopedics for bone defect treatment based on numerical analyses because they mimic the trabecular bone properties.