TCTin Tai Chow

Tin Tai Chow

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tin Tai Chow has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Unlocking Rooftop Cooling Potential: An Experimental Investigation of the Thermal Behavior of Cool Roof and Green Roof as Retrofitting Strategies in Hot–Humid Climate

    by Tengfei Zhao, Kwong Fai Fong, Tin Tai Chow

    Cool roof and green roof have been acknowledged as effective heat mitigation strategies for fighting against the urban heat island (UHI). However, empirical data in hot–humid climate are still insufficient. Experimental conventional, cool and green roofs (three types) were established to comprehensively investigate the thermal performances in Hong Kong under typical summer conditions, as retrofitting strategies for an office building. The holistic vertical thermal behavior was investigated. The comparative cooling potentials were assessed. The results reveal a “vertical thermal sequence” in peak temperatures of each substrate layer for the conventional, cool and green roofs on a sunny day. However, local reversion in the thermal sequence may occur on a rainy day. Green roof-plot C (GR_C) demonstrates the highest thermal damping effect, followed by plot B (GR_B), A (GR_A) and the cool roof (CR) in summer. On a sunny day, the thermal dampening effectiveness of the substrates in the three green roofs is consistent: drainage > soil > water reservoir > root barrier. The holistic vertical thermal profiling was constructed in a high-rise office context in Hong Kong. The diurnal temperature profiles indicate all roof systems could effectively attenuate the temperature fluctuations. The daily maximum surface temperature reduction (SDMR) was introduced for cooling potential characterization of the cool roof and green roofs with multiple vegetation types. On a sunny day, the cool roof and green roofs all showed significant cooling potential. SDMR on the concrete tile of the best performing system was GR_C (26 °C), followed by GR_B (22.4 °C), GR_A (20.7 °C) and CR (13.3 °C), respectively. The SDMR on the ceiling ranked as GR_C, GR_B, GR_A and CR, with 2.9 °C, 2.4 °C, 2.1 °C and 2.1 °C, separately. On a rainy day, the cooling effect was still present but greatly diminished. A critical insight of a “warming effect at the ceiling” of the green roof was revealed. This research offers critical insights for unlocking rooftop cooling potential, endorsing cool roof and green roof as pivotal solutions for sustainable urban environments.


  • Design Guidelines for Stratum Ventilation

    by Zhang Lin, Ting Yao, T. T. Chow, K. F. Fong, L. S. Chan

  • Short-term load forecasting coupled with weather profile generation methodology

    by Guangya Zhu, Tin-Tai Chow, Norman Tse

    Short-term building load forecasting is indispensable in daily operation of future intelligent/green buildings, particularly in formulating system control strategies and assessing the associated environmental impacts. Most previous research works have been focused on studying the advancement in forecasting techniques, but not as much on evaluating the availability of influential factors like the predicted weather profile in the coming hours. This article proposes an improved procedure to predict the building load 24 hours ahead, together with a backup weather profile generating method. The quality of the proposed weather profile generation model and the forecasting procedures were examined through a case study of application to university academic buildings. The results showed that the load forecasting accuracy with the application of either the real weather data on record or of the predicted weather data from the profile generation model is very much similar. This indicates that the weather prediction model is suitable for applying to building load forecasting. Besides, the comparisons between different sets of input data illustrated that the forecasting accuracy can be improved through the input data filtering and regrouping procedures. Practical application: A weather profile prediction technique for use in building energy forecasting was introduced. This can be coupled to a building energy use forecasting model for predicting the hourly consumption profile of the next day. This prediction time span can be crucial for formulating the daily operation plan of the utility systems or for smart micro-grid applications. The appropriateness of the methodology was evaluated through a case study.


  • Influence of human movement on the transport of airborne infectious particles in hospital

    by Jinliang Wang, Tin-Tai Chow

    The impacts of human movement on the distribution of airborne infectious particles in hospital environment are investigated numerically. In the case of airborne infection isolation room, the influence of different walking speeds on the distribution of respiratory droplets is investigated by adopting the Lagrangian method for tracing the motion of droplets, the dynamic mesh model for describing human walking and the Eulerian unsteady Reynolds-averaged Navier–Stokes model for solving the airflow. In the case of operating theatre, the impact of surgeon bending movement on the distribution of bacteria-carrying particles (BCPs) is investigated by using a similar approach, except that the drift-flux model is used for modelling BCPs distribution. The adopted models are successfully validated against reported experimental data. The results show that both walking speed and bending posture change considerably the suspended droplets concentration in a room. The key factors regarding the simulation techniques are discussed.


  • Experimental study of evacuated-tube solar water heaters in Hong Kong

    by T-T Chow, L-S Chan, K-F Fong, R Tan, Z Dong

    The evacuated tube solar water heaters are widely in use today. But so far their thermal performance has not been systematically evaluated, despite the increased popularity. An experimental solar hot water system including two collector types, namely water-in-glass and heat-pipe, of evacuated tube solar water heater has been set up. Their capacity is typical for serving single family domestic hot water system. Performance tests were carried out in Hong Kong and under almost identical boundary conditions by placing the two collectors side-by-side. The energy performance has been analysed and the daily efficiency, transient efficiency and night-time heat loss were compared. While the energy acquisition performance of the heat-pipe collector design is found slightly better, the heat loss performance is found weaker than the water-in-glass collector design.


  • Experimental evaluation of ventilated glazing performance in Hong Kong

    by T. T. Chow, C. Li, Z. Lin, K. F. Fong, L. S. Chan, G. Pei


  • A Comparative Study of PV Glazing Performance in Warm Climate

    by T.T. Chow, G. Pei, L.S. Chan, Z. Lin, K.F. Fong

    In this experimental study, the performance of ventilated double-pane glazing integrated with semi-transparent solar cells under the subtropical climate of Hong Kong has been investigated. The effects of a photovoltaic (PV) ventilated glazing system on the built environment — including heat and light transmission, thermal and visual comfort, and electricity generation — were analyzed and discussed. While the energy saving potential of PV glazing on air-conditioning demands was found promising, the same on daylight utilization was much inferior to the absorptive glazing applications. The purpose of the study was to gain experience on better use of the semi-transparent PV ventilated glazing technology, and on the energy/cost saving potential of some innovative arrangements.


  • A Computer Evaluation of Ventilation Performance in a Negative-Pressure Operating Theater

    by Tin-Tai Chow, Anne Kwan, Zhang Lin, Wei Bai

    A negative-pressure operating theater is required to limit the spread of respiratory diseases in patients with severe acute respiratory syndrome, tuberculosis, avian influenza, or similar infectious diseases. In Hong Kong, we converted a conventional operating theater into a negative-pressure operating theater that has been in service for more than a year. In this article, we introduce its ventilation design and evaluate the airflow performance in relation to different combinations of medical lamp configurations and modes of launching infectious particles into the room air. We used a computational fluid dynamics technique for the numerical analysis. Our analyses showed that the airflow performance in the negative-pressure operating theater was satisfactory and comparable to the original positive-pressure design. The airflow pattern effectively controlled the dispersion of infectious particles. Our calculations demonstrated that the airflow contained the dispersion of infectious particles released from the patient sufficiently to protect the surgical team, and vice versa. Computational fluid dynamics can be used to assess airflow in a negative-pressure operating room and model the dispersion of infectious particles from the patient.