Olga Lavrova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Olga Lavrova has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
- Satish Ranade
New Mexico State University, Las Cruces, NM, USA
7 shared publications - Matthew J. Reno
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
4 shared publications - Sijo Augustine
Klipsch School of Electrical & Computer Engineering, College of Engineering, New Mexico State University, Las Cruces, NM 88001, USA
3 shared publications - Deepak Ramasubramanian
EPRI, Palo Alto, CA, USA
2 shared publications Gabriel Cowles
Urban Electric Power, Pearl River, NY, USA
2 shared publications- Huzaifa Karimjee
Klipsch School of Electrical and Computer Engineering, New Mexico State University, Las Cruces, NM, USA
2 shared publications
Latest Publications
- Open Access
Mission-Profile-Aware Physics-of-Failure Reliability Assessment and Quantitative FMEA of a 10 kW Solid-State Transformer
Solid-state transformers (SSTs) are pivotal for next-generation power systems, yet their widespread adoption is hindered by reliability uncertainties under diverse operational conditions. This paper introduces a mission-profile-aware, physics-of-failure (PoF) reliability assessment framework that explicitly links operating conditions, degradation mechanisms, and statistical uncertainty. The approach combines PoF models for stress-sensitive components with handbook-based reliability models for passive elements, employing Joint Electron Device Engineering Council (JEDEC)-aligned statistical methods for failure rate extraction. Quantitative failure-in-time (FIT) estimates are integrated into a physics-informed Failure mode and effects analysis (FMEA), replacing subjective occurrence rankings with FIT-derived quantitative occurrence ratings while retaining explicit severity and detection criteria. The framework is demonstrated on a 10 kW Type-IV SST across multiple mission profiles and ambient temperatures. The results reveal that the system-level mean time between failures (MTBF) varies from 4.6 to over 8 years, with gate-driver electronics and DC-link capacitors dominating FIT contributions. Mission-dependent shifts in failure mechanisms highlight the inadequacy of single MTBF metrics. This scalable framework provides a foundation for reliability-oriented SST design, qualification, and deployment.
Open AccessMission-Profile-Aware Physics-of-Failure Reliability Assessment and Quantitative FMEA of a 10 kW Solid-State Transformer
Solid-state transformers (SSTs) are pivotal for next-generation power systems, yet their widespread adoption is hindered by reliability uncertainties under diverse operational conditions. This paper introduces a mission-profile-aware, physics-of-failure (PoF) reliability assessment framework that explicitly links operating conditions, degradation mechanisms, and statistical uncertainty. The approach combines PoF models for stress-sensitive components with handbook-based reliability models for passive elements, employing Joint Electron Device Engineering Council (JEDEC)-aligned statistical methods for failure rate extraction. Quantitative failure-in-time (FIT) estimates are integrated into a physics-informed Failure mode and effects analysis (FMEA), replacing subjective occurrence rankings with FIT-derived quantitative occurrence ratings while retaining explicit severity and detection criteria. The framework is demonstrated on a 10 kW Type-IV SST across multiple mission profiles and ambient temperatures. The results reveal that the system-level mean time between failures (MTBF) varies from 4.6 to over 8 years, with gate-driver electronics and DC-link capacitors dominating FIT contributions. Mission-dependent shifts in failure mechanisms highlight the inadequacy of single MTBF metrics. This scalable framework provides a foundation for reliability-oriented SST design, qualification, and deployment.
- Top Cited PapersOpen Access
A Review on Protection and Cybersecurity in Hybrid AC/DC Microgrids: Conventional Challenges and AI/ML Approaches
Hybrid AC/DC microgrids (HMGs) are increasingly recognized as a solution for the transition toward future energy systems because they can combine the efficiency of DC networks with an AC system. Despite these advantages, HMGs still have challenges in protection, cybersecurity, and reliability. Conventional protection schemes often fail due to reduced fault currents and the dominance of power electronic converters in islanded or dynamically reconfigured topologies. At the same time, IEC 61850 protocols remain vulnerable to advanced cyberattacks such as Denial of Service (DoS), false data injection (FDIA), and man-in-the-middle (MITM), posing serious threats to the stability and operational security of intelligent power networks. Previous surveys have typically examined these challenges in isolation; however, this paper provides the first integrated review of HMG protection across three complementary dimensions: traditional protection schemes, cybersecurity threats, and artificial intelligence/machine learning (AI/ML)-based approaches. By analyzing more than 100 studies published between 2012 and 2024, we show that AI/ML methods in simulation environments can achieve detection accuracies of 95–98% with response times under 10 ms, while these values are case-specific and depend on the evaluation setting such as network scale, sampling configuration, noise levels, inverter control mode, and whether results are obtained in simulation, hardware in loop (HIL)/real-time digital simulator (RTDS), or field conditions. Nevertheless, the absence of standardized datasets and limited field validation remain key barriers to industrial adoption. Likewise, existing cybersecurity frameworks provide acceptable protection timing but lack resilience against emerging threats, while conventional methods underperform in clustered and islanded scenarios. Therefore, the future of HMG protection requires the integration of traditional schemes, resilient cybersecurity architectures, and explainable AI models, along with the development of benchmark datasets, hardware-in-the-loop validation, and implementation on platforms such as field-programmable gate array (FPGA) and μPMU.
Top Cited PapersOpen AccessA Review on Protection and Cybersecurity in Hybrid AC/DC Microgrids: Conventional Challenges and AI/ML Approaches
Hybrid AC/DC microgrids (HMGs) are increasingly recognized as a solution for the transition toward future energy systems because they can combine the efficiency of DC networks with an AC system. Despite these advantages, HMGs still have challenges in protection, cybersecurity, and reliability. Conventional protection schemes often fail due to reduced fault currents and the dominance of power electronic converters in islanded or dynamically reconfigured topologies. At the same time, IEC 61850 protocols remain vulnerable to advanced cyberattacks such as Denial of Service (DoS), false data injection (FDIA), and man-in-the-middle (MITM), posing serious threats to the stability and operational security of intelligent power networks. Previous surveys have typically examined these challenges in isolation; however, this paper provides the first integrated review of HMG protection across three complementary dimensions: traditional protection schemes, cybersecurity threats, and artificial intelligence/machine learning (AI/ML)-based approaches. By analyzing more than 100 studies published between 2012 and 2024, we show that AI/ML methods in simulation environments can achieve detection accuracies of 95–98% with response times under 10 ms, while these values are case-specific and depend on the evaluation setting such as network scale, sampling configuration, noise levels, inverter control mode, and whether results are obtained in simulation, hardware in loop (HIL)/real-time digital simulator (RTDS), or field conditions. Nevertheless, the absence of standardized datasets and limited field validation remain key barriers to industrial adoption. Likewise, existing cybersecurity frameworks provide acceptable protection timing but lack resilience against emerging threats, while conventional methods underperform in clustered and islanded scenarios. Therefore, the future of HMG protection requires the integration of traditional schemes, resilient cybersecurity architectures, and explainable AI models, along with the development of benchmark datasets, hardware-in-the-loop validation, and implementation on platforms such as field-programmable gate array (FPGA) and μPMU.
- Open Access
Distributed Model Predictive Control-Based Power Management Scheme for Grid-Integrated Microgrids
Transitioning from traditional electrical grids to smart grids is currently an ongoing process that many nations are striving for due to their access to renewable resources. Energy management is one of the key parameters that decides the performance of such complex systems. Distributed Model Predictive Control (DMPC) is a promising technique that can be used to improve the energy management of grid-connected systems. This paper analyzes a grid-connected inverter system with DMPC that exchanges key operating parameters with the grid to optimize coordinated power sharing between its respective loads. The state-space model for the inverter is derived and verified to ensure controllability and observability. A state observer for an inverter system is then developed to estimate the nominal states in the derived state-space model. The system performance is evaluated with MATLAB simulation by implementing load disturbances, which validate the effectiveness of the proposed power management control algorithm.
Open AccessDistributed Model Predictive Control-Based Power Management Scheme for Grid-Integrated Microgrids
Transitioning from traditional electrical grids to smart grids is currently an ongoing process that many nations are striving for due to their access to renewable resources. Energy management is one of the key parameters that decides the performance of such complex systems. Distributed Model Predictive Control (DMPC) is a promising technique that can be used to improve the energy management of grid-connected systems. This paper analyzes a grid-connected inverter system with DMPC that exchanges key operating parameters with the grid to optimize coordinated power sharing between its respective loads. The state-space model for the inverter is derived and verified to ensure controllability and observability. A state observer for an inverter system is then developed to estimate the nominal states in the derived state-space model. The system performance is evaluated with MATLAB simulation by implementing load disturbances, which validate the effectiveness of the proposed power management control algorithm.
- Open Access
- 3 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 207033-207046
Inverter-Agnostic DC-Coupled Solar+Storage System
This paper describes a connection method and a control algorithm to embed battery storage with solar panels with the grid interface provided by industry-standard microinverters. By emulating an appropriate i-v characteristic based on the charge/discharge requirements, the integrated panel can work with any inverter, such as a battery inverter in droop mode, or a peak power tracking inverter. The efficacy of the concept is demonstrated using simulation studies and an implementation using rechargeable zinc-manganese dioxide (ZnMnO2) battery cells. The cells, developed by Urban Electric Power (UEP), can withstand high temperatures and thus are suitable for rooftop/outdoor applications. The inverter-agnostic, ’solar+storage’ source would be attractive in new, retrofit, and standalone applications.
- 3 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 207033-207046
Open AccessInverter-Agnostic DC-Coupled Solar+Storage System
This paper describes a connection method and a control algorithm to embed battery storage with solar panels with the grid interface provided by industry-standard microinverters. By emulating an appropriate i-v characteristic based on the charge/discharge requirements, the integrated panel can work with any inverter, such as a battery inverter in droop mode, or a peak power tracking inverter. The efficacy of the concept is demonstrated using simulation studies and an implementation using rechargeable zinc-manganese dioxide (ZnMnO2) battery cells. The cells, developed by Urban Electric Power (UEP), can withstand high temperatures and thus are suitable for rooftop/outdoor applications. The inverter-agnostic, ’solar+storage’ source would be attractive in new, retrofit, and standalone applications.
- Open Access
- 13 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 11-20
Beyond the Breaker: Evaluating Post-Quantum Cryptographic Algorithms for Practical Smart Grid Deployment
- 13 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 11-20
Open AccessBeyond the Breaker: Evaluating Post-Quantum Cryptographic Algorithms for Practical Smart Grid Deployment
- 7 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (3) , 2655-2666
An Analysis of Grid-Forming Inverters in Blackstart Applications During Transformer Energization Sequence
The increasing penetration of inverter-based resources (IBRs) necessitates a reassessment of current grid practices. Blackstart is one specialized area that has drawn renewed attention due to the capability of grid-forming inverters (GFMIs) to emulate synchronous generators (SG). The ability of IBRs to carry out a blackstart represents a novel concept necessitating deeper investigations, particularly given the constraints of IBRs such as over-current limitations, which affect the energization of non-linear network devices. This paper presents a blackstart case study that uses a GFMI, focusing on the energization of a large unloaded plant transformer. Consequently, a unique inrush is demonstrated, known as a sympathetic inrush between the plant and the inverter medium-voltage (MV) transformer. Subsequently, an alternative method for the execution of soft energization (SE) is introduced using a power plant controller (PPC), eliminating inverter-level control modifications. Furthermore, the impact of employing the SE method on inrush currents is evaluated using the proposed method, and a qualitative analysis is lastly presented comparing SE to the hard switching (HS) blackstart method. Collectively, this paper aims to demonstrate the GFMI's ability, using both the SE and HS methods, to energize transformers which play an important role during a blackstart.
- 7 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (3) , 2655-2666
An Analysis of Grid-Forming Inverters in Blackstart Applications During Transformer Energization Sequence
The increasing penetration of inverter-based resources (IBRs) necessitates a reassessment of current grid practices. Blackstart is one specialized area that has drawn renewed attention due to the capability of grid-forming inverters (GFMIs) to emulate synchronous generators (SG). The ability of IBRs to carry out a blackstart represents a novel concept necessitating deeper investigations, particularly given the constraints of IBRs such as over-current limitations, which affect the energization of non-linear network devices. This paper presents a blackstart case study that uses a GFMI, focusing on the energization of a large unloaded plant transformer. Consequently, a unique inrush is demonstrated, known as a sympathetic inrush between the plant and the inverter medium-voltage (MV) transformer. Subsequently, an alternative method for the execution of soft energization (SE) is introduced using a power plant controller (PPC), eliminating inverter-level control modifications. Furthermore, the impact of employing the SE method on inrush currents is evaluated using the proposed method, and a qualitative analysis is lastly presented comparing SE to the hard switching (HS) blackstart method. Collectively, this paper aims to demonstrate the GFMI's ability, using both the SE and HS methods, to energize transformers which play an important role during a blackstart.
- Open Access
- 13 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 173156-173167
Facility Rating Standards Review and Proposed Methodology for FERC Order 881 AAR Calculation
FERC rule 881 requires the use of ambient-adjusted ratings (AAR) instead of standard static line ratings (SLR) to ensure more precise assessments of the maximum transfer capability of transmission lines. AAR offers several advantages, resulting in improved transfer capacities. However, the practical details of calculations of AARs require careful and detailed consideration. This paper describes the rationale, procedures and technical references used as a basis for determining AARs for FERC Order 881 compliance. IEEE standards concerning the individual power facilities are reviewed for references to ambient temperature and solar heating. The formulas, references and other relevant information are consolidated in the paper providing the necessary information to perform AAR calculations. Additionally the paper provides recommendations on developing, where applicable, conservative equipment-type rating scaling factors to be used across a utility’s fleet.
- 13 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 173156-173167
Open AccessFacility Rating Standards Review and Proposed Methodology for FERC Order 881 AAR Calculation
FERC rule 881 requires the use of ambient-adjusted ratings (AAR) instead of standard static line ratings (SLR) to ensure more precise assessments of the maximum transfer capability of transmission lines. AAR offers several advantages, resulting in improved transfer capacities. However, the practical details of calculations of AARs require careful and detailed consideration. This paper describes the rationale, procedures and technical references used as a basis for determining AARs for FERC Order 881 compliance. IEEE standards concerning the individual power facilities are reviewed for references to ambient temperature and solar heating. The formulas, references and other relevant information are consolidated in the paper providing the necessary information to perform AAR calculations. Additionally the paper provides recommendations on developing, where applicable, conservative equipment-type rating scaling factors to be used across a utility’s fleet.
- Open Access
Insights on Blackstart Provisioning Using a Synchronous Generator and Grid-Forming Inverter Using EMT Simulations
Grid-forming inverters (GFMIs) have been identified as critical assets in ensuring modern power system reliability. Their ability to synthesize an internal voltage reference while emulating synthetic inertia has sparked extensive research. These characteristics have recently piqued interest in their capacity to provide blackstart ancillary services. The blackstart of a bulk power system poses significant challenges, namely the large transients from the energization of unloaded transformers, rotational motor loads, and long transmission cables, which have been effectively studied using conventional synchronous generators (SGs). The concept of an inverter-based resource (IBR)-based blackstart continues to be an open research area necessitating further investigations due to the known limitations of IBRs such as low short-circuit current capabilities. This paper presents a blackstart case study of a bulk power system investigating the performances of a conventional SG to a GFMI when utilizing hard switching methods. The paper qualitatively investigates the transient inrush currents from the transformer and rotational load energization sequences. Additional examinations into the significance of the GFMI’s current-limiting schemes and voltage control loop compensator gains are presented. Furthermore, the harmonic distortions from the transformer energization sequence are also evaluated. Finally, a full network energization case is presented to demonstrate how both sources can provide blackstart provisioning services. The models are developed in EMTDC/PSCAD using real-world transmission planning data.
Open AccessInsights on Blackstart Provisioning Using a Synchronous Generator and Grid-Forming Inverter Using EMT Simulations
Grid-forming inverters (GFMIs) have been identified as critical assets in ensuring modern power system reliability. Their ability to synthesize an internal voltage reference while emulating synthetic inertia has sparked extensive research. These characteristics have recently piqued interest in their capacity to provide blackstart ancillary services. The blackstart of a bulk power system poses significant challenges, namely the large transients from the energization of unloaded transformers, rotational motor loads, and long transmission cables, which have been effectively studied using conventional synchronous generators (SGs). The concept of an inverter-based resource (IBR)-based blackstart continues to be an open research area necessitating further investigations due to the known limitations of IBRs such as low short-circuit current capabilities. This paper presents a blackstart case study of a bulk power system investigating the performances of a conventional SG to a GFMI when utilizing hard switching methods. The paper qualitatively investigates the transient inrush currents from the transformer and rotational load energization sequences. Additional examinations into the significance of the GFMI’s current-limiting schemes and voltage control loop compensator gains are presented. Furthermore, the harmonic distortions from the transformer energization sequence are also evaluated. Finally, a full network energization case is presented to demonstrate how both sources can provide blackstart provisioning services. The models are developed in EMTDC/PSCAD using real-world transmission planning data.
- Open Access
- 18 March 2024
- Published by Institution of Engineering and Technology (IET) in IET Energy Systems Integration
- Vol. 6 (4) , 465-478
Mitigation of limitation imposed on hosting capacity in low voltage networks by their distribution transformer loading and degradation considerations
A distribution transformer's thermal operating conditions can impose a limitation on the Hosting Capacity (HC) of an electrical distribution feeder for PV interconnections in the feeder's low‐voltage network. This is undesirable as it curtails PV interconnection of both residential and commercial customers in the secondary networks at a time when there are record numbers of interconnection requests by utilities' customers. The authors analyse the limitations on HC due to transformer loading and degradation considerations. Then, the paper proposes a battery energy storage system (BESS) dispatch strategy that will mitigate the limitation on distribution feeder HC by distribution transformers. Three scenarios of HC were simulated for a test network—HC evaluation without restrictions by the distribution transformer (scenario 1), HC evaluation with restrictions by the distribution transformer (scenario 2), and HC evaluation without restriction by the distribution transformer, and with the implementation of the proposed BESS mitigation strategy (scenario 3). Simulation results show that transformer lifetime is depleted to about 6% of expected lifetime for unrestricted HC in scenario 1. Curtailing the HC by 32% in scenario 2 improves the lifetime to 149% of expected lifetime. Implementing the proposed BESS in scenario 3 improves the transformer lifetime to 127% and increases the HC by 62% above the curtailed value in scenario 2, and by 10% above the original HC in scenario 1. The BESS strategy implementation produced cost savings of 49% and 27% of the transformer cost in scenarios 2 and 3, respectively, due to deferred transformer replacement. Conversely, there is a 1600% replacement cost incurred in scenario 1, which underscores the need for a mitigation strategy. The proposed BESS strategy does not only improve the HC of a distribution feeder but also increases a distribution transformer's lifetime leading to replacement cost savings.
- 18 March 2024
- Published by Institution of Engineering and Technology (IET) in IET Energy Systems Integration
- Vol. 6 (4) , 465-478
Open AccessMitigation of limitation imposed on hosting capacity in low voltage networks by their distribution transformer loading and degradation considerations
A distribution transformer's thermal operating conditions can impose a limitation on the Hosting Capacity (HC) of an electrical distribution feeder for PV interconnections in the feeder's low‐voltage network. This is undesirable as it curtails PV interconnection of both residential and commercial customers in the secondary networks at a time when there are record numbers of interconnection requests by utilities' customers. The authors analyse the limitations on HC due to transformer loading and degradation considerations. Then, the paper proposes a battery energy storage system (BESS) dispatch strategy that will mitigate the limitation on distribution feeder HC by distribution transformers. Three scenarios of HC were simulated for a test network—HC evaluation without restrictions by the distribution transformer (scenario 1), HC evaluation with restrictions by the distribution transformer (scenario 2), and HC evaluation without restriction by the distribution transformer, and with the implementation of the proposed BESS mitigation strategy (scenario 3). Simulation results show that transformer lifetime is depleted to about 6% of expected lifetime for unrestricted HC in scenario 1. Curtailing the HC by 32% in scenario 2 improves the lifetime to 149% of expected lifetime. Implementing the proposed BESS in scenario 3 improves the transformer lifetime to 127% and increases the HC by 62% above the curtailed value in scenario 2, and by 10% above the original HC in scenario 1. The BESS strategy implementation produced cost savings of 49% and 27% of the transformer cost in scenarios 2 and 3, respectively, due to deferred transformer replacement. Conversely, there is a 1600% replacement cost incurred in scenario 1, which underscores the need for a mitigation strategy. The proposed BESS strategy does not only improve the HC of a distribution feeder but also increases a distribution transformer's lifetime leading to replacement cost savings.
- Open Access
- 1 January 2024
- Published by International Journal of Renewable Energy Research in International Journal of Smart grid
- Vol. 8 (V8i3) , 130-139
Current Limiting Schemes and their Stability Implications for Blackstart of Power Systems with Inverter-Based Resources (IBRs)
Current Limiting Schemes and their Stability Implications for Blackstart of Power Systems with Inverter-Based Resources (IBRs)
- 1 January 2024
- Published by International Journal of Renewable Energy Research in International Journal of Smart grid
- Vol. 8 (V8i3) , 130-139
Open AccessCurrent Limiting Schemes and their Stability Implications for Blackstart of Power Systems with Inverter-Based Resources (IBRs)
Current Limiting Schemes and their Stability Implications for Blackstart of Power Systems with Inverter-Based Resources (IBRs)