WKWei Kuang
Wei Kuang
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wei Kuang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Chenglong Xiong
School of Urban Construction, Wuhan University of Science and Technology, Wuhan 430065, China
1 shared publication - Chongchong Wang
School of Urban Construction, Wuhan University of Science and Technology, Wuhan 430065, China
1 shared publication - Guannan Li
School of Urban Construction, Wuhan University of Science and Technology, Wuhan, China
1 shared publication - Lamei Liu
School of Urban Construction, Wuhan University of Science and Technology, Wuhan, China
1 shared publication - Xi Fang
College of Civil Engineering, Hunan University, Changsha 410082, China
1 shared publication
Latest Publications
- Open Access
Study on Sensor Fault-Tolerant Control for Central Air-Conditioning Systems Using Bayesian Inference with Data Increments
A lack of available information on heating, ventilation, and air-conditioning (HVAC) systems can affect the performance of data-driven fault-tolerant control (FTC) models. This study proposed an in situ selective incremental calibration (ISIC) strategy. Faults were introduced into the indoor air () thermostat and supply air temperature () and chilled water supply air temperature () sensors of a central air-conditioning system. The changes in the system performance after FTC were evaluated. Then, we considered the effects of the data quality, data volume, and variable number on the FTC results. For the thermostat and sensor, the system energy consumption was reduced by 2.98% and 3.72% with ISIC, respectively, and the predicted percentage dissatisfaction was reduced by 0.67% and 0.63%, respectively. Better FTC results were obtained using ISIC when the thermostat had low noise, a 7-day data volume, or sufficient variables and when the and sensors had low noise, a 14-day data volume, or limited variables.Open AccessStudy on Sensor Fault-Tolerant Control for Central Air-Conditioning Systems Using Bayesian Inference with Data Increments
A lack of available information on heating, ventilation, and air-conditioning (HVAC) systems can affect the performance of data-driven fault-tolerant control (FTC) models. This study proposed an in situ selective incremental calibration (ISIC) strategy. Faults were introduced into the indoor air () thermostat and supply air temperature () and chilled water supply air temperature () sensors of a central air-conditioning system. The changes in the system performance after FTC were evaluated. Then, we considered the effects of the data quality, data volume, and variable number on the FTC results. For the thermostat and sensor, the system energy consumption was reduced by 2.98% and 3.72% with ISIC, respectively, and the predicted percentage dissatisfaction was reduced by 0.67% and 0.63%, respectively. Better FTC results were obtained using ISIC when the thermostat had low noise, a 7-day data volume, or sufficient variables and when the and sensors had low noise, a 14-day data volume, or limited variables.