Vladimir V. Sheikin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vladimir V. Sheikin has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Ekaterina G. Komarova
Institute of Strength Physics and Materials Science, Siberian Branch of the Russian Academy of Sciences
3 shared publications - Mariya Borisovna Sedelnikova
Institute of Strength Physics and Materials Science, Siberian Branch, Russian Academy of Sciences, Tomsk, Russia
3 shared publications - Yurii P. Sharkeev
Institute of Strength Physics and Materials Science, Siberian Branch of the Russian Academy of Sciences
3 shared publications - Tatiana V. Tolkacheva
Institute of Strength Physics and Materials Science, Siberian Branch of the Russian Academy of Sciences
2 shared publications - A. N. Osipov
Tomsk Medical Instrument LLC
1 shared publication - Aigerim A. Kazakbaeva
Tomsk State University, 36 Lenin ave., Tomsk, 634050, Russia
1 shared publication
Latest Publications
- Open Access
- 1 December 2019
- Published by KEAI Publishing in Bioactive Materials
- Vol. 4, 224-235
Modification of titanium surface via Ag-, Sr- and Si-containing micro-arc calcium phosphate coating
The current research is devoted to the study of the modification of the titanium implants by the micro-arc oxidation with bioactive calcium phosphate coatings containing Ag or Sr and Si elements. The coatings' microstructure, phase composition, morphology, physicochemical and biological properties were examined by scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDX) and X-ray diffraction (XRD). Ag-containing and Sr-Si-incorporated coatings were formed in alkaline and acid electrolytes, respectively. The formation of the coatings occurred at different ranges of the applied voltages, which led to the significant difference in the coatings properties. The trace elements Ag, Sr and Si participated intensively in the plasma-chemical reactions of the micro-arc coatings formation. Ag-containing coatings demonstrated strong antibacterial effect against Staphylococcus aureus AТСС 6538-P. MTT in vitro test with 3T3-L1 fibroblasts showed no cytotoxicity appearance on Sr-Si-incorporated coatings.
- 1 December 2019
- Published by KEAI Publishing in Bioactive Materials
- Vol. 4, 224-235
Open AccessModification of titanium surface via Ag-, Sr- and Si-containing micro-arc calcium phosphate coating
The current research is devoted to the study of the modification of the titanium implants by the micro-arc oxidation with bioactive calcium phosphate coatings containing Ag or Sr and Si elements. The coatings' microstructure, phase composition, morphology, physicochemical and biological properties were examined by scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDX) and X-ray diffraction (XRD). Ag-containing and Sr-Si-incorporated coatings were formed in alkaline and acid electrolytes, respectively. The formation of the coatings occurred at different ranges of the applied voltages, which led to the significant difference in the coatings properties. The trace elements Ag, Sr and Si participated intensively in the plasma-chemical reactions of the micro-arc coatings formation. Ag-containing coatings demonstrated strong antibacterial effect against Staphylococcus aureus AТСС 6538-P. MTT in vitro test with 3T3-L1 fibroblasts showed no cytotoxicity appearance on Sr-Si-incorporated coatings.
- Open Access
Characterization of the Micro-Arc Coatings Containing β-Tricalcium Phosphate Particles on Mg-0.8Ca Alloy
The characterization of the microstructure, morphology, topography, composition, and physical and chemical properties of the coatings containing β-tricalcium phosphate (β-TCP) particles deposited by the micro-arc oxidation (MAO) method on biodegradable Mg-0.8Ca alloy has been performed. The electrolyte for the MAO process included the following components: Na2HPO4·12H2O, NaOH, NaF, and β-Ca3(PO4)2 (β-TCP). The coating morphology, microstructure, and compositions have been studied using scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDX), and X-ray diffraction (XRD). With increasing of the MAO voltage from 350 to 500 V, the coating thickness and surface average roughness of the coatings increased linearly from 6 to 150 µm and from 2 to 8 µm, respectively. The coating deposited at 350 V had more homogeneous porous morphology with numerous pores similar by sizes (2–3 µm) than the coatings formed at 450–500 V. The β-TCP isometric particles were included in the coating surface. The XRD recognized the amorphous-crystalline structure in the coatings with incorporation of the following phases: β-TCP, α-TCP, MgO (periclase) and hydroxyapatite (HA). The corrosion experiments showed that the biodegradation rate of the Mg-0.8Ca alloy coated by calcium phosphates is almost 10 times less than that of uncoated alloy.
Open AccessCharacterization of the Micro-Arc Coatings Containing β-Tricalcium Phosphate Particles on Mg-0.8Ca Alloy
The characterization of the microstructure, morphology, topography, composition, and physical and chemical properties of the coatings containing β-tricalcium phosphate (β-TCP) particles deposited by the micro-arc oxidation (MAO) method on biodegradable Mg-0.8Ca alloy has been performed. The electrolyte for the MAO process included the following components: Na2HPO4·12H2O, NaOH, NaF, and β-Ca3(PO4)2 (β-TCP). The coating morphology, microstructure, and compositions have been studied using scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDX), and X-ray diffraction (XRD). With increasing of the MAO voltage from 350 to 500 V, the coating thickness and surface average roughness of the coatings increased linearly from 6 to 150 µm and from 2 to 8 µm, respectively. The coating deposited at 350 V had more homogeneous porous morphology with numerous pores similar by sizes (2–3 µm) than the coatings formed at 450–500 V. The β-TCP isometric particles were included in the coating surface. The XRD recognized the amorphous-crystalline structure in the coatings with incorporation of the following phases: β-TCP, α-TCP, MgO (periclase) and hydroxyapatite (HA). The corrosion experiments showed that the biodegradation rate of the Mg-0.8Ca alloy coated by calcium phosphates is almost 10 times less than that of uncoated alloy.
- 1 March 2016
- Published by Pleiades Publishing Ltd in Inorganic Materials: Applied Research
- Vol. 7 (2) , 226-232
Modification of titanium medical agraffe surface for suturing instruments with microarc oxidation method
- 1 March 2016
- Published by Pleiades Publishing Ltd in Inorganic Materials: Applied Research
- Vol. 7 (2) , 226-232
Modification of titanium medical agraffe surface for suturing instruments with microarc oxidation method
- Open Access
- 1 January 2016
- Published by Siberian State Medical University in Bulletin of Siberian Medicine
- Vol. 15 (2) , 76-84
TECHNOLOGICAL BASIS FOR THE CREATION OF IMPLANTS WITH A PHARMACEUTICAL COMPOSITION OF CIPROFLOXACIN AND THEIR ANTIMICROBIAL ACTIVITY IN EXPERIMENTS IN VITRO
С целью снижения риска развития инфекционных осложнений в постимплантационный период и повышения эффективности хирургического лечения изучали возможность иммобилизации на поверхность титановых имплантируемых устройств (модельные пластинки, «п-образные» скобки) лекарственного вещества антимикробного действия. Материал и методы. Объектом исследований являлись модельные титановые пластинки и титановые «п-образные» скобки для инструмента сшивающего «ГЕРА-10» (ООО «НПО ТМИ», Томск) с модифицированной методом лазерной абляции поверхностью. В качестве действующего вещества разрабатываемой фармацевтической композиции использован ципрофлоксацин, в качестве вспомогательных компонентов – растворы метилцеллюлозы и гидроксипропилметилцеллюлозы. Антимикробную активность имплантируемых объектов с фармацевтической композицией определяли методом диффузии в агар на плотной питательной среде путем изучения размеров зон угнетения роста тест-штаммов микроорганизмов (S. aureus, P. аeruginosa, E. coli , E. faecalis и S. pyogenes). Результаты. В результате исследований показана возможность нанесения и удержания лекарственного вещества в пазах на модифицированной поверхности титановых имплантатов. Предложены фармацевтические композиции ципрофлоксацина с использованием в качестве связывающего и матрицеобразующего компонента гидроксипропилметилцеллюлозы. Установлено отсутствие зависимости между структурой поверхности рабочих элементов модельных пластинок со способностью связывания и удержания фармацевтической композиции на имплантатах. Выявлено, что кратность нанесения фармацевтической композиции непосредственно влияет на количественное содержание лекарственного вещества, а также на закрепление композиции на поверхности имплантата. Наиболее оптимально одноили двукратное нанесение в зависимости от требуемой дозы лекарственного вещества. В экспериментах in vitro выявлена выраженная антимикробная активность «п-образных» скобок с ципрофлоксацином в отношении S. aureus, P. аeruginosa, E. coli, E. faecalis и S. pyogenes, что свидетельствует о целесообразности использования скобок с иммобилизованным на их поверхности антимикробным веществом с целью снижения вероятности развития имплантат-ассоциированной инфекции в постоперационный период.
- 1 January 2016
- Published by Siberian State Medical University in Bulletin of Siberian Medicine
- Vol. 15 (2) , 76-84
Open AccessTECHNOLOGICAL BASIS FOR THE CREATION OF IMPLANTS WITH A PHARMACEUTICAL COMPOSITION OF CIPROFLOXACIN AND THEIR ANTIMICROBIAL ACTIVITY IN EXPERIMENTS IN VITRO
С целью снижения риска развития инфекционных осложнений в постимплантационный период и повышения эффективности хирургического лечения изучали возможность иммобилизации на поверхность титановых имплантируемых устройств (модельные пластинки, «п-образные» скобки) лекарственного вещества антимикробного действия. Материал и методы. Объектом исследований являлись модельные титановые пластинки и титановые «п-образные» скобки для инструмента сшивающего «ГЕРА-10» (ООО «НПО ТМИ», Томск) с модифицированной методом лазерной абляции поверхностью. В качестве действующего вещества разрабатываемой фармацевтической композиции использован ципрофлоксацин, в качестве вспомогательных компонентов – растворы метилцеллюлозы и гидроксипропилметилцеллюлозы. Антимикробную активность имплантируемых объектов с фармацевтической композицией определяли методом диффузии в агар на плотной питательной среде путем изучения размеров зон угнетения роста тест-штаммов микроорганизмов (S. aureus, P. аeruginosa, E. coli , E. faecalis и S. pyogenes). Результаты. В результате исследований показана возможность нанесения и удержания лекарственного вещества в пазах на модифицированной поверхности титановых имплантатов. Предложены фармацевтические композиции ципрофлоксацина с использованием в качестве связывающего и матрицеобразующего компонента гидроксипропилметилцеллюлозы. Установлено отсутствие зависимости между структурой поверхности рабочих элементов модельных пластинок со способностью связывания и удержания фармацевтической композиции на имплантатах. Выявлено, что кратность нанесения фармацевтической композиции непосредственно влияет на количественное содержание лекарственного вещества, а также на закрепление композиции на поверхности имплантата. Наиболее оптимально одноили двукратное нанесение в зависимости от требуемой дозы лекарственного вещества. В экспериментах in vitro выявлена выраженная антимикробная активность «п-образных» скобок с ципрофлоксацином в отношении S. aureus, P. аeruginosa, E. coli, E. faecalis и S. pyogenes, что свидетельствует о целесообразности использования скобок с иммобилизованным на их поверхности антимикробным веществом с целью снижения вероятности развития имплантат-ассоциированной инфекции в постоперационный период.