David Li
David Li has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Abdul Baqi
Mercy Saint Vincent Medical Center, Toledo, OH
2 shared publications - Ameer Mustafa Farrukh
University of Galway, school of medicine, Ireland
2 shared publications - Bader Do Semakieh
Arkansas College of Osteopathic Medicine, Fort Smith, AR
2 shared publications - Muhammad Afzal
St. George’s University School of Medicine, True Blue, Grenada
2 shared publications - Naod F. Belay
Michigan State University, East Lansing, MI
2 shared publications - Qaisar Ali Khan
Khyber Teaching Hospital MTI KTH, Peshawar, Pakistan
2 shared publications
Latest Publications
- Open Access
- 26 January 2024
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 86 (7) , 4060-4074
Comparing outcomes of balloon-expandable vs. self-expandable valves in transcatheter aortic valve replacement: a systematic review and meta-analysis
Background: Aortic stenosis (AS) is a common heart condition categorized into congenital and acquired forms. Transcatheter aortic valve replacement (TAVR) is an innovative method for AS management, and two valve types, self-expanding valves (SEV) and balloon-expandable valves (BEV), are used in TAVR. The objective of this study is to compare the clinical outcomes associated with balloon-expandable and self-expandable valves in transcatheter aortic valve replacement. Methods: The researchers conducted a comprehensive meta-analysis following PRISMA guidelines and AMSTAR-2 tool. The methodology involved a systematic literature search, strict eligibility criteria, unbiased study selection, meticulous data extraction, quality assessment, and rigorous statistical analysis. Results: Our analysis included twenty-six papers and 26 553 patients. BEV exhibited significant advantages over SEV in overall mortality across 21 studies, particularly in perioperative and 30-day assessments. However, no substantial disparities emerged between the two valve types in stroke incidence. BEV demonstrated notable benefits in reducing hospitalization rates across 6 studies and significantly fewer instances of permanent pacemaker implantations across 19 studies, particularly evident in the perioperative setting. Other secondary outcomes like bleeding, acute kidney injury, and myocardial infarction showcased non-significant differences between BEV and SEV. Conclusion: The analysis indicates that BEV may offer benefits in specific aspects of TAVR outcomes, but further research is needed to fully understand the factors influencing patient outcomes and mortality in TAVR procedures.
- 26 January 2024
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 86 (7) , 4060-4074
Open AccessComparing outcomes of balloon-expandable vs. self-expandable valves in transcatheter aortic valve replacement: a systematic review and meta-analysis
Background: Aortic stenosis (AS) is a common heart condition categorized into congenital and acquired forms. Transcatheter aortic valve replacement (TAVR) is an innovative method for AS management, and two valve types, self-expanding valves (SEV) and balloon-expandable valves (BEV), are used in TAVR. The objective of this study is to compare the clinical outcomes associated with balloon-expandable and self-expandable valves in transcatheter aortic valve replacement. Methods: The researchers conducted a comprehensive meta-analysis following PRISMA guidelines and AMSTAR-2 tool. The methodology involved a systematic literature search, strict eligibility criteria, unbiased study selection, meticulous data extraction, quality assessment, and rigorous statistical analysis. Results: Our analysis included twenty-six papers and 26 553 patients. BEV exhibited significant advantages over SEV in overall mortality across 21 studies, particularly in perioperative and 30-day assessments. However, no substantial disparities emerged between the two valve types in stroke incidence. BEV demonstrated notable benefits in reducing hospitalization rates across 6 studies and significantly fewer instances of permanent pacemaker implantations across 19 studies, particularly evident in the perioperative setting. Other secondary outcomes like bleeding, acute kidney injury, and myocardial infarction showcased non-significant differences between BEV and SEV. Conclusion: The analysis indicates that BEV may offer benefits in specific aspects of TAVR outcomes, but further research is needed to fully understand the factors influencing patient outcomes and mortality in TAVR procedures.
- Open Access
- 8 December 2023
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 86 (2) , 958-967
Effect of Azilsartan on clinical blood pressure reduction compared to other angiotensin receptor blockers: a systematic review and meta-analysis
Background: Hypertension has significantly contributed to morbidity and mortality, necessitating effective management. Angiotensin receptor blockers (ARBs) have emerged as a cornerstone in hypertension treatment. Azilsartan, a relatively recent addition to the ARB family, offers unique characteristics, including prodrug activation. This systematic review and meta-analysis aimed to evaluate Azilsartan’s role in reducing clinical blood pressure compared to other ARBs and determine the most effective dosage. Methods: Following PRISMA guidelines, a comprehensive literature search was conducted in Medline, Web of Science, Cochrane Library, and clinicaltrials.gov. Eligible studies included adult hypertensive patients receiving Azilsartan compared to other ARBs, with clinical systolic blood pressure (SBP) and diastolic blood pressure (DBP) outcomes. Data extraction and quality assessment were performed, and statistical analysis employed comprehensive meta-analysis (CMA) software. Results: Eleven randomized controlled trials encompassing 18 studies involving 6024 patients were included. Azilsartan demonstrated significant reductions in clinical SBP (mean difference=−2.85 mmHg) and DBP (mean difference=−2.095 mmHg) compared to other ARBs. Higher doses of Azilsartan showed greater efficacy, with 80 mg exhibiting the most substantial reduction in SBP. The analysis emphasized the need for more studies investigating lower Azilsartan doses (10 and 20 mg). Conclusion: This systematic review and meta-analysis underscore Azilsartan’s effectiveness in reducing SBP and DBP. Dose-dependent effects emphasize the importance of optimal dosing when prescribing Azilsartan. These findings provide valuable insights for clinicians in managing hypertension effectively and call for further research, primarily focusing on lower Azilsartan doses and a more diverse patient population.
- 8 December 2023
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 86 (2) , 958-967
Open AccessEffect of Azilsartan on clinical blood pressure reduction compared to other angiotensin receptor blockers: a systematic review and meta-analysis
Background: Hypertension has significantly contributed to morbidity and mortality, necessitating effective management. Angiotensin receptor blockers (ARBs) have emerged as a cornerstone in hypertension treatment. Azilsartan, a relatively recent addition to the ARB family, offers unique characteristics, including prodrug activation. This systematic review and meta-analysis aimed to evaluate Azilsartan’s role in reducing clinical blood pressure compared to other ARBs and determine the most effective dosage. Methods: Following PRISMA guidelines, a comprehensive literature search was conducted in Medline, Web of Science, Cochrane Library, and clinicaltrials.gov. Eligible studies included adult hypertensive patients receiving Azilsartan compared to other ARBs, with clinical systolic blood pressure (SBP) and diastolic blood pressure (DBP) outcomes. Data extraction and quality assessment were performed, and statistical analysis employed comprehensive meta-analysis (CMA) software. Results: Eleven randomized controlled trials encompassing 18 studies involving 6024 patients were included. Azilsartan demonstrated significant reductions in clinical SBP (mean difference=−2.85 mmHg) and DBP (mean difference=−2.095 mmHg) compared to other ARBs. Higher doses of Azilsartan showed greater efficacy, with 80 mg exhibiting the most substantial reduction in SBP. The analysis emphasized the need for more studies investigating lower Azilsartan doses (10 and 20 mg). Conclusion: This systematic review and meta-analysis underscore Azilsartan’s effectiveness in reducing SBP and DBP. Dose-dependent effects emphasize the importance of optimal dosing when prescribing Azilsartan. These findings provide valuable insights for clinicians in managing hypertension effectively and call for further research, primarily focusing on lower Azilsartan doses and a more diverse patient population.