Guoan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Guoan Li has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Shay Zayontz
3 shared publicationsEphrat Most
2 shared publicationsErik Otterberg
2 shared publicationsHarry Rubash
2 shared publicationsKenneth Sabbag
2 shared publicationsBertram Zarins
Orthopaedic Biomechanics Laboratory, Harvard Medical School, MGH/BIDMC, 330 Brookline Avenue, RN 115, Boston, MA 02215, USA
1 shared publication
Latest Publications
- 1 November 2002
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 404 (404) , 214-225
Biomechanics of Posterior-Substituting Total Knee Arthroplasty: An In Vitro Study
The cam-spine system in posterior-substituting total knee arthroplasty was designed to improve posterior stability and to increase posterior femoral translation (rollback). Little is known on its effectiveness in the restoration of femoral rollback under functional loads. In the current study, the effect of cam-spine engagement on knee motion under simulated muscle loads was investigated using knees from cadavers. The translations of the lateral and medial femoral condyles of the knee before and after total knee arthroplasty were compared from 0° to 120° flexion. Cam-spine contact forces were measured under the same muscle loads. The posterior translations of both femoral condyles in the total knee arthroplasty were significantly lower than that of the native knee beyond full extension. Cam-spine engagement occurred between 60° and 90° flexion followed by an increase in posterior translation of both femoral condyles. However, the resultant femoral translation of the total knee arthroplasty was still lower than that of the native knee from 90° to 120° flexion. Knee motion after cam-spine engagement was independent of muscle loads, indicating the importance of the cam-spine mechanism at high flexion angles. Decreased posterior translation of both femoral condyles after total knee arthroplasty may be a limiting factor at high flexion.
- 1 November 2002
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 404 (404) , 214-225
Biomechanics of Posterior-Substituting Total Knee Arthroplasty: An In Vitro Study
The cam-spine system in posterior-substituting total knee arthroplasty was designed to improve posterior stability and to increase posterior femoral translation (rollback). Little is known on its effectiveness in the restoration of femoral rollback under functional loads. In the current study, the effect of cam-spine engagement on knee motion under simulated muscle loads was investigated using knees from cadavers. The translations of the lateral and medial femoral condyles of the knee before and after total knee arthroplasty were compared from 0° to 120° flexion. Cam-spine contact forces were measured under the same muscle loads. The posterior translations of both femoral condyles in the total knee arthroplasty were significantly lower than that of the native knee beyond full extension. Cam-spine engagement occurred between 60° and 90° flexion followed by an increase in posterior translation of both femoral condyles. However, the resultant femoral translation of the total knee arthroplasty was still lower than that of the native knee from 90° to 120° flexion. Knee motion after cam-spine engagement was independent of muscle loads, indicating the importance of the cam-spine mechanism at high flexion angles. Decreased posterior translation of both femoral condyles after total knee arthroplasty may be a limiting factor at high flexion.
- 1 July 2002
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 20 (4) , 887-892
Biomechanical consequences of PCL deficiency in the knee under simulated muscle loads—an in vitro experimental study
The mechanism of chronic degeneration of the knee after posterior cruciate ligament (PCL) injury is still not clearly understood. While numerous biomechanical studies have been conducted to investigate the function of the PCL with regard to antero‐posterior stability of the knee, little has been reported on its effect on the rotational stability of the knee. In this study, eight cadaveric human knee specimens were tested on a robotic testing system from full extension to 120° of flexion with the PCL intact and with the PCL resected. The antero‐posterior tibial translation and the internal‐external tibial rotation were measured when the knee was subjected to various simulated muscle loads. Under a quadriceps load (400 N) and a combined quadriceps/hamstring load (400/200 N), the tibia moved anteriorly at low flexion angles (below 60°). Resection of the PCL did not significantly alter anterior tibial translation. At high flexion angles (beyond 60°), the tibia moved posteriorly and rotated externally under the muscle loads. PCL deficiency significantly increased the posterior tibial translation and external tibial rotation. The results of this study indicate that PCL deficiency not only changed tibial translation, but also tibial rotation. Therefore, only evaluating the tibial translation in the anteroposterior direction may not completely describe the effect of PCL deficiency on knee joint function. Furthermore, the increased external tibial rotations were further hypothesized to cause elevated patello‐femoral joint contact pressures. These data may help explain the biomechanical factors causing long‐term degenerative changes of the knee after PCL injury. By fully understanding the etiology of these changes, it may be possible to develop an optimal surgical treatment for PCL injury that is aimed at minimizing the long‐term arthritic changes in the knee joint. © 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
- 1 July 2002
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 20 (4) , 887-892
Biomechanical consequences of PCL deficiency in the knee under simulated muscle loads—an in vitro experimental study
The mechanism of chronic degeneration of the knee after posterior cruciate ligament (PCL) injury is still not clearly understood. While numerous biomechanical studies have been conducted to investigate the function of the PCL with regard to antero‐posterior stability of the knee, little has been reported on its effect on the rotational stability of the knee. In this study, eight cadaveric human knee specimens were tested on a robotic testing system from full extension to 120° of flexion with the PCL intact and with the PCL resected. The antero‐posterior tibial translation and the internal‐external tibial rotation were measured when the knee was subjected to various simulated muscle loads. Under a quadriceps load (400 N) and a combined quadriceps/hamstring load (400/200 N), the tibia moved anteriorly at low flexion angles (below 60°). Resection of the PCL did not significantly alter anterior tibial translation. At high flexion angles (beyond 60°), the tibia moved posteriorly and rotated externally under the muscle loads. PCL deficiency significantly increased the posterior tibial translation and external tibial rotation. The results of this study indicate that PCL deficiency not only changed tibial translation, but also tibial rotation. Therefore, only evaluating the tibial translation in the anteroposterior direction may not completely describe the effect of PCL deficiency on knee joint function. Furthermore, the increased external tibial rotations were further hypothesized to cause elevated patello‐femoral joint contact pressures. These data may help explain the biomechanical factors causing long‐term degenerative changes of the knee after PCL injury. By fully understanding the etiology of these changes, it may be possible to develop an optimal surgical treatment for PCL injury that is aimed at minimizing the long‐term arthritic changes in the knee joint. © 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
- 1 May 2002
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 30 (5) , 713-720
The Effect of Anterior Cruciate Ligament Injury on Knee Joint Function under a Simulated Muscle Load: A Three-Dimensional Computational Simulation
Understanding the biomechanical effect of various factors on knee behavior after anterior cruciate ligament (ACL) injury or reconstruction is instrumental for the development of an optimal surgical...
- 1 May 2002
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 30 (5) , 713-720
The Effect of Anterior Cruciate Ligament Injury on Knee Joint Function under a Simulated Muscle Load: A Three-Dimensional Computational Simulation
Understanding the biomechanical effect of various factors on knee behavior after anterior cruciate ligament (ACL) injury or reconstruction is instrumental for the development of an optimal surgical...
- 1 December 2001
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 16 (8) , 150-156
Cruciate-retaining and cruciate-substituting total knee arthroplasty: An in vitro comparison of the kinematics under muscle loads
- 1 December 2001
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 16 (8) , 150-156
Cruciate-retaining and cruciate-substituting total knee arthroplasty: An in vitro comparison of the kinematics under muscle loads
- 13 March 2001
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 123 (4) , 341-346
Variability of a Three-Dimensional Finite Element Model Constructed Using Magnetic Resonance Images of a Knee for Joint Contact Stress Analysis
Magnetic resonance (MR) imaging has been widely used to evaluate the thickness and volume of articular cartilage both in vivo and in vitro. While morphological information on the cartilage can be obtained using MR images, image processing for extracting geometric boundaries of the cartilage may introduce variations in the thickness of the cartilage. To evaluate the variability of using MR images to construct finite element (FE) knee cartilage models, five investigators independently digitized the same set of MR images of a human knee. The topology of cartilage thickness was determined using a minimal distance algorithm. Less than 8 percent variation in cartilage thickness was observed from the digitized data. The effect of changes in cartilage thickness on contact stress analysis was then investigated using five FE models of the knee. One FE model (average FE model) was constructed using the mean values of the digitized contours of the cartilage, and the other four were constructed by varying the thickness of the average FE model by and respectively. The results demonstrated that under axial tibial compressive loading (up to 1400 N), variations of cartilage thickness caused by digitization of MR images may result in a difference of approximately 10 percent in peak contact stresses (surface pressure, von Mises stress, and hydrostatic pressure) in the cartilage. A reduction of cartilage thickness caused increases of contact stresses, while an increase of cartilage thickness reduced contact stresses. Furthermore, the effect of variation of material properties of the cartilage on contact stress analysis was investigated. The peak contact stress increased almost linearly with the Young’s modulus of the cartilage. The peak von Mises stress was dramatically reduced when the Poisson’s ratio was increased from 0.05 to 0.49 under an axial compressive load of 1400 N, while peak hydrostatic pressure was dramatically increased. Peak surface pressure was also increased with the Poisson’s ratio, but with a lower magnitude compared to von Mises stress and hydrostatic pressure. In conclusion, the imaging process may cause 10 percent variations in peak contact stress, and the predicted stress distribution is sensitive to the accuracy of the material properties of the cartilage model, especially to the variation of Poisson’s ratio.- 13 March 2001
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 123 (4) , 341-346
Variability of a Three-Dimensional Finite Element Model Constructed Using Magnetic Resonance Images of a Knee for Joint Contact Stress Analysis
Magnetic resonance (MR) imaging has been widely used to evaluate the thickness and volume of articular cartilage both in vivo and in vitro. While morphological information on the cartilage can be obtained using MR images, image processing for extracting geometric boundaries of the cartilage may introduce variations in the thickness of the cartilage. To evaluate the variability of using MR images to construct finite element (FE) knee cartilage models, five investigators independently digitized the same set of MR images of a human knee. The topology of cartilage thickness was determined using a minimal distance algorithm. Less than 8 percent variation in cartilage thickness was observed from the digitized data. The effect of changes in cartilage thickness on contact stress analysis was then investigated using five FE models of the knee. One FE model (average FE model) was constructed using the mean values of the digitized contours of the cartilage, and the other four were constructed by varying the thickness of the average FE model by and respectively. The results demonstrated that under axial tibial compressive loading (up to 1400 N), variations of cartilage thickness caused by digitization of MR images may result in a difference of approximately 10 percent in peak contact stresses (surface pressure, von Mises stress, and hydrostatic pressure) in the cartilage. A reduction of cartilage thickness caused increases of contact stresses, while an increase of cartilage thickness reduced contact stresses. Furthermore, the effect of variation of material properties of the cartilage on contact stress analysis was investigated. The peak contact stress increased almost linearly with the Young’s modulus of the cartilage. The peak von Mises stress was dramatically reduced when the Poisson’s ratio was increased from 0.05 to 0.49 under an axial compressive load of 1400 N, while peak hydrostatic pressure was dramatically increased. Peak surface pressure was also increased with the Poisson’s ratio, but with a lower magnitude compared to von Mises stress and hydrostatic pressure. In conclusion, the imaging process may cause 10 percent variations in peak contact stress, and the predicted stress distribution is sensitive to the accuracy of the material properties of the cartilage model, especially to the variation of Poisson’s ratio.