Sami Schranz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sami Schranz has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Pesaresi
Neurosurgery Unit, University of Turin, A.O.U. Città della Salute e della Scienza, Turin, Italy
2 shared publications - Daniele Starnoni
Department of Clinical Neurosciences, Neurosurgery Service and Gamma Knife Center, Centre Hospitalier Universitaire Vaudois (CHUV), Lausanne, Switzerland
2 shared publications - Hugues Cadas
Unite Facultaire d’Anatomie et de Morphologie (UFAM), University Center of Legal Medicine Lausanne-Geneva (CURML), Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland
2 shared publications - Lorenzo Dolci
Neurosurgery Unit, University of Turin, A.O.U. Città della Salute e della Scienza, Turin, Italy
2 shared publications - Lorenzo Giammattei
Department of Neurosurgery, Lausanne University Hospital, Lausanne, Switzerland
2 shared publications - Roy Thomas Daniel
Department of Neurosurgery, Lausanne University Hospital, Lausanne, Switzerland
2 shared publications
Latest Publications
- Open Access
- 11 November 2026
- Published by Wolters Kluwer Health in Operative Neurosurgery
Anatomic and Ergonomic Impact of C1 Transversectomy on the Anterolateral OA–V3 Bypass Corridor: A Cadaveric Study
BACKGROUND AND OBJECTIVES: The occipital artery–vertebral artery (OA–VA) bypass of the V3 segment has been described as a possible feasible revascularization strategy through the anterolateral approach. However, the impact of C1 transverse process removal on surgical corridor expansion, VA mobility, and microsurgical ergonomics has not been evaluated. In this cadaveric study, we assessed the anatomic and ergonomic effect of C1 transversectomy for OA–V3 bypass. METHODS: Five injected cadaveric specimens (10 sides) were subjected to paired analysis comparing standard anterolateral exposure (baseline) vs the same approach with C1 transversectomy and VA skeletonization. Quantitative end points included surgical working area, exposed VA length, working depth, and instrument divergence angle. Paired statistical analysis was calculated. RESULTS: C1 transversectomy resulted in a significant improvement in all major parameters of surgical exposure. The working area increased by 130% (from 226.1 to 519.1 mm 2 , P < .001), whereas the exposed VA length increased by 84% (from 12.7 to 23.4 mm, P = .002). VA mobility demonstrated the greatest relative gain, increasing by 207% (from 1.5 to 4.6 mm, P < .001). The instrument divergence angle also significantly improved, increasing by 109% (from 18.2° to 38.1°, P < .001). No statistically significant changes were observed in working depth. CONCLUSION: C1 transversectomy markedly enhances exposure, mobility, and operative ergonomics within the anterolateral OA–V3 corridor. These findings provide quantitative anatomic validation of a technical refinement that may improve reproducibility and safety of OA–VA bypass in selected clinical scenarios.
- 11 November 2026
- Published by Wolters Kluwer Health in Operative Neurosurgery
Open AccessAnatomic and Ergonomic Impact of C1 Transversectomy on the Anterolateral OA–V3 Bypass Corridor: A Cadaveric Study
BACKGROUND AND OBJECTIVES: The occipital artery–vertebral artery (OA–VA) bypass of the V3 segment has been described as a possible feasible revascularization strategy through the anterolateral approach. However, the impact of C1 transverse process removal on surgical corridor expansion, VA mobility, and microsurgical ergonomics has not been evaluated. In this cadaveric study, we assessed the anatomic and ergonomic effect of C1 transversectomy for OA–V3 bypass. METHODS: Five injected cadaveric specimens (10 sides) were subjected to paired analysis comparing standard anterolateral exposure (baseline) vs the same approach with C1 transversectomy and VA skeletonization. Quantitative end points included surgical working area, exposed VA length, working depth, and instrument divergence angle. Paired statistical analysis was calculated. RESULTS: C1 transversectomy resulted in a significant improvement in all major parameters of surgical exposure. The working area increased by 130% (from 226.1 to 519.1 mm 2 , P < .001), whereas the exposed VA length increased by 84% (from 12.7 to 23.4 mm, P = .002). VA mobility demonstrated the greatest relative gain, increasing by 207% (from 1.5 to 4.6 mm, P < .001). The instrument divergence angle also significantly improved, increasing by 109% (from 18.2° to 38.1°, P < .001). No statistically significant changes were observed in working depth. CONCLUSION: C1 transversectomy markedly enhances exposure, mobility, and operative ergonomics within the anterolateral OA–V3 corridor. These findings provide quantitative anatomic validation of a technical refinement that may improve reproducibility and safety of OA–VA bypass in selected clinical scenarios.
- Open Access
- 10 August 2026
- Published by Elsevier in Forensic Imaging
- Vol. 46
Extracorporeal membrane oxygenation- modified Grabherr’s multi-phase post-mortem CT angiography protocol
- 10 August 2026
- Published by Elsevier in Forensic Imaging
- Vol. 46
Open AccessExtracorporeal membrane oxygenation- modified Grabherr’s multi-phase post-mortem CT angiography protocol
- Open Access
Whole human organ clearing and multimodal mapping
Human anatomy has traditionally been studied using low-resolution approaches such as cadaveric dissection and conventional medical imaging, limiting our understanding of macroscopic structures. Tissue clearing has emerged as a transformative approach, enabling three-dimensional mapping of organs at microscopic resolution, and offering the opportunity to interrogate anatomy across scales. However, its application to human organs remains challenging due to their size, density and optical properties. Here, we establish multiorgan CleLight (mCleLight) as a generalizable method for clearing, labeling and imaging whole human tissues. mCleLight is broadly applicable across major organ systems and enables the analysis of particularly challenging specimens, including highly heterogeneous samples, dense bones, pigmented tissues and decades-old formalin-fixed archival material. We demonstrate that controlled photoclearing is critical across human tissues both for efficient clearing and for quenching endogenous fluorescence, thereby substantially improving imaging depth as compared to previous methods. mCleLight allows specific labeling and quantitative analysis of complex extended structures such as collagen fibers, vasculature, and innervation, while preserving anatomical relationships, which cannot be easily done with classical histology. We integrated mCleLight into a pipeline with clinical imaging to achieve a comprehensive, multiscale understanding of organ architecture. We demonstrate the voxel-by-voxel alignment between MRI and microscopy datasets, merging cellular-scale detail and protein- specific labeling with macroscopic medical imaging. By bridging the gap between imaging scales and modalities, mCleLight provides a versatile method for integrated three- dimensional histological mapping and macroscopic anatomy of human organs in health and disease.
Open AccessWhole human organ clearing and multimodal mapping
Human anatomy has traditionally been studied using low-resolution approaches such as cadaveric dissection and conventional medical imaging, limiting our understanding of macroscopic structures. Tissue clearing has emerged as a transformative approach, enabling three-dimensional mapping of organs at microscopic resolution, and offering the opportunity to interrogate anatomy across scales. However, its application to human organs remains challenging due to their size, density and optical properties. Here, we establish multiorgan CleLight (mCleLight) as a generalizable method for clearing, labeling and imaging whole human tissues. mCleLight is broadly applicable across major organ systems and enables the analysis of particularly challenging specimens, including highly heterogeneous samples, dense bones, pigmented tissues and decades-old formalin-fixed archival material. We demonstrate that controlled photoclearing is critical across human tissues both for efficient clearing and for quenching endogenous fluorescence, thereby substantially improving imaging depth as compared to previous methods. mCleLight allows specific labeling and quantitative analysis of complex extended structures such as collagen fibers, vasculature, and innervation, while preserving anatomical relationships, which cannot be easily done with classical histology. We integrated mCleLight into a pipeline with clinical imaging to achieve a comprehensive, multiscale understanding of organ architecture. We demonstrate the voxel-by-voxel alignment between MRI and microscopy datasets, merging cellular-scale detail and protein- specific labeling with macroscopic medical imaging. By bridging the gap between imaging scales and modalities, mCleLight provides a versatile method for integrated three- dimensional histological mapping and macroscopic anatomy of human organs in health and disease.
- Open Access
- 14 July 2026
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 48 (1)
Intravascular injection of colored molding materials for human anatomy teaching: a literature review
Purpose: Intravascular injection of colored molding materials used either alone or in combination with radiological contrast agents is increasingly used to enhance vascular visualization in cadaveric specimens for anatomical education and surgical training. Published studies remain scattered and show substantial methodological variation. This structured literature review summarizes current practices regarding specimen preparation, injection techniques, casting materials, contrast agents, and imaging modalities, with particular emphasis on their educational applications. Materials and methods: A comprehensive literature search was conducted in PubMed, Scopus, Embase, Web of Science, and Google Scholar (1975–August 2025) using English, French, and German keywords. Reference lists were screened manually. After removal of duplicates, 702 records were screened, 145 full-text articles assessed, and 78 studies included. Results: Included studies demonstrated variability in casting materials (primarily latex, with silicone, epoxy, and acrylic resins also reported), contrast agents (iodinated and barium-based compounds and lead oxide for CT, with gadolinium-based formulations predominantly used for MRI), perfusion pressures, flushing strategies, and specimen conditions (fresh-frozen, formalin-fixed, and Thiel-embalmed). However, methodological heterogeneity and inconsistent reporting limited direct comparison between approaches. The review nevertheless identifies representative reported technical protocols and highlights the main practical variables influencing protocol selection. Conclusion: Contrast-enhanced vascular casting provides valuable tools for anatomy education and surgical training by enabling direct correlation between radiological datasets and anatomical dissection. Beyond summarizing the literature, this review also offers practical protocol-selection guidance according to educational, research, and imaging objectives. As such, it may serve as a useful reference for teams implementing or refining these techniques in modern teaching environments.
- 14 July 2026
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 48 (1)
Open AccessIntravascular injection of colored molding materials for human anatomy teaching: a literature review
Purpose: Intravascular injection of colored molding materials used either alone or in combination with radiological contrast agents is increasingly used to enhance vascular visualization in cadaveric specimens for anatomical education and surgical training. Published studies remain scattered and show substantial methodological variation. This structured literature review summarizes current practices regarding specimen preparation, injection techniques, casting materials, contrast agents, and imaging modalities, with particular emphasis on their educational applications. Materials and methods: A comprehensive literature search was conducted in PubMed, Scopus, Embase, Web of Science, and Google Scholar (1975–August 2025) using English, French, and German keywords. Reference lists were screened manually. After removal of duplicates, 702 records were screened, 145 full-text articles assessed, and 78 studies included. Results: Included studies demonstrated variability in casting materials (primarily latex, with silicone, epoxy, and acrylic resins also reported), contrast agents (iodinated and barium-based compounds and lead oxide for CT, with gadolinium-based formulations predominantly used for MRI), perfusion pressures, flushing strategies, and specimen conditions (fresh-frozen, formalin-fixed, and Thiel-embalmed). However, methodological heterogeneity and inconsistent reporting limited direct comparison between approaches. The review nevertheless identifies representative reported technical protocols and highlights the main practical variables influencing protocol selection. Conclusion: Contrast-enhanced vascular casting provides valuable tools for anatomy education and surgical training by enabling direct correlation between radiological datasets and anatomical dissection. Beyond summarizing the literature, this review also offers practical protocol-selection guidance according to educational, research, and imaging objectives. As such, it may serve as a useful reference for teams implementing or refining these techniques in modern teaching environments.
- Open Access
- 25 March 2026
- Published by MDPI AG in Brain Sciences
- Vol. 16 (4) , 351
Redefining Access to the Mesiotemporal Lobe: The Transplanum Polare Approach with Cadaveric and Operative Video Demonstration
Objectives: This study aims to define the surgical anatomy, technical feasibility, advantages, and limitations of the TPPA through detailed cadaveric dissection and a representative clinical case, evaluating its potential as a safe and effective alternative to traditional approaches to the mesiotemporal lobe. Methods: A cadaveric dissection was performed on one adult head injected with colored latex, using standard microsurgical instruments and high-definition video documentation. Each procedural step was recorded and illustrated with cadaveric photographs. Additionally, a clinical case of mesiotemporal cavernous hemangioma resected via TPPA is presented, including an operative video. Results: The dissection demonstrated a direct and safe trajectory to the amygdala and hippocampal head, with clear identification of key vascular and white matter landmarks. In the clinical case, the lesion was completely resected with no postoperative neurological deficits. Conclusions: The TPPA represents a novel microsurgical corridor to the mesiotemporal region, minimizing cortical disruption, Sylvian fissure dissection, and manipulation of middle cerebral artery branches. Although its exposure is limited posteriorly, the TPPA could offer an optimal balance between functional preservation and surgical accessibility, constituting a valuable addition to the modern microsurgical armamentarium.
- 25 March 2026
- Published by MDPI AG in Brain Sciences
- Vol. 16 (4) , 351
Open AccessRedefining Access to the Mesiotemporal Lobe: The Transplanum Polare Approach with Cadaveric and Operative Video Demonstration
Objectives: This study aims to define the surgical anatomy, technical feasibility, advantages, and limitations of the TPPA through detailed cadaveric dissection and a representative clinical case, evaluating its potential as a safe and effective alternative to traditional approaches to the mesiotemporal lobe. Methods: A cadaveric dissection was performed on one adult head injected with colored latex, using standard microsurgical instruments and high-definition video documentation. Each procedural step was recorded and illustrated with cadaveric photographs. Additionally, a clinical case of mesiotemporal cavernous hemangioma resected via TPPA is presented, including an operative video. Results: The dissection demonstrated a direct and safe trajectory to the amygdala and hippocampal head, with clear identification of key vascular and white matter landmarks. In the clinical case, the lesion was completely resected with no postoperative neurological deficits. Conclusions: The TPPA represents a novel microsurgical corridor to the mesiotemporal region, minimizing cortical disruption, Sylvian fissure dissection, and manipulation of middle cerebral artery branches. Although its exposure is limited posteriorly, the TPPA could offer an optimal balance between functional preservation and surgical accessibility, constituting a valuable addition to the modern microsurgical armamentarium.
- Open Access
- 4 December 2025
- Published by Springer Nature in International journal of legal medicine
- Vol. 140 (2) , 857-866
Automatic rib fracture detection on postmortem CT data using deep learning
Objectives: To assess the performance of automatic rib fracture detection of an existing deep learning (DL) model, nnDetection, on a postmortem (PM) CT scan dataset, and to identify the main factors of domain shift between clinical and PM CT imaging. Background: Rib fracture detection and classification in forensic investigations is a time-consuming yet crucial task that can contribute to determine the cause of death. DL models are a promising tool, as recent research shows that radiologists using DL models can detect rib fractures in clinical CT scans at higher sensitivity and in shorter time. Methods: A dataset of 50 PMCT scans (24% women; age: mean 61, range 19 – 96 years) was retrospectively collected and annotated, and used to train a first instance of the model, nnDetPM. Another instance of the model, nnDetClin, was trained on data from another dataset, RibFrac, consisting of 660 clinical CT scans (36% women; age: mean 55, range 21 – 94 years). Results: On the PM testing set, nnDetPM achieved an average sensitivity of 70.2% and an average precision (at 0.1 intersection over union) of 78.1%, whereas nnDetClin fell far behind at 19.8% average sensitivity and 25.5% average precision, indicating a substantial impact of the domain shift from clinical to PM CT data. Further inspection of the results showed that the main factors of this domain shift were the position of the arms and the presence of medical ware in the image acquisition area of the PMCT scans. Conclusion: The performance of nnDetPM, with an average sensitivity of 70.2%, was notable and comparable to that of radiologists. However, more advanced techniques must be explored to decide if DL models can overcome the domain shift factors.
- 4 December 2025
- Published by Springer Nature in International journal of legal medicine
- Vol. 140 (2) , 857-866
Open AccessAutomatic rib fracture detection on postmortem CT data using deep learning
Objectives: To assess the performance of automatic rib fracture detection of an existing deep learning (DL) model, nnDetection, on a postmortem (PM) CT scan dataset, and to identify the main factors of domain shift between clinical and PM CT imaging. Background: Rib fracture detection and classification in forensic investigations is a time-consuming yet crucial task that can contribute to determine the cause of death. DL models are a promising tool, as recent research shows that radiologists using DL models can detect rib fractures in clinical CT scans at higher sensitivity and in shorter time. Methods: A dataset of 50 PMCT scans (24% women; age: mean 61, range 19 – 96 years) was retrospectively collected and annotated, and used to train a first instance of the model, nnDetPM. Another instance of the model, nnDetClin, was trained on data from another dataset, RibFrac, consisting of 660 clinical CT scans (36% women; age: mean 55, range 21 – 94 years). Results: On the PM testing set, nnDetPM achieved an average sensitivity of 70.2% and an average precision (at 0.1 intersection over union) of 78.1%, whereas nnDetClin fell far behind at 19.8% average sensitivity and 25.5% average precision, indicating a substantial impact of the domain shift from clinical to PM CT data. Further inspection of the results showed that the main factors of this domain shift were the position of the arms and the presence of medical ware in the image acquisition area of the PMCT scans. Conclusion: The performance of nnDetPM, with an average sensitivity of 70.2%, was notable and comparable to that of radiologists. However, more advanced techniques must be explored to decide if DL models can overcome the domain shift factors.
- Open Access
- 29 January 2024
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 43 (2) , 101646
3D printed splint designed by 3D surface scanner for patients with hand allodynia
- 29 January 2024
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 43 (2) , 101646
Open Access3D printed splint designed by 3D surface scanner for patients with hand allodynia