Sofia Kakalejčíková
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sofia Kakalejčíková has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Maksym Fizer
Department of Chemistry, University of Nevada, Reno, 1664 N. Virginia Street, Reno, NV 89557-0216, USA
4 shared publications - Yaroslav Bazel
Department of Analytical Chemistry, P.J. Šafárik University in Košice, 04154 Košice, Slovakia
3 shared publications - Dominik Harenčár
Department of Analytical Chemistry, Institute of Chemistry, Faculty of Science, Pavol Jozef Safarik University in Kosice, Moyzesova 11, 040 01 Kosice, Slovakia
1 shared publication - Mária Drábiková
Department of Analytical Chemistry, Institute of Chemistry, Faculty of Science, Pavol Jozef Šafárik University in Košice, 040 01 Košice, Slovakia
1 shared publication - Van Anh Le Thi
Department of Analytical Chemistry, Institute of Chemistry, Pavol Jozef Šafárik University in Košice, 040 01 Košice, Slovakia
1 shared publication Yaroslav Bazel
Department of Analytical Chemistry, Institute of Chemistry, Pavol Jozef Šafárik University in Košice, Košice, Slovak Republic
1 shared publication
Latest Publications
- Open Access
Fluorimetric Determination of Eosin Y in Water Samples and Drinks Using Deep Eutectic Solvent-Based Liquid-Phase Microextraction
An environmentally friendly and highly sensitive analytical method for the determination of the dye Eosin Y (EY) was developed utilizing vortex-assisted liquid–liquid microextraction based on deep eutectic solvents (DESs), combined with fluorescence detection (LPME-FLD). The extraction efficiencies of conventional solvents and various DES systems, composed of tetrabutylammonium bromide (TBAB) and alcohols (hexanol, octanol, and decanol) in different ratios, were systematically compared. DFT calculations provided insights into the most stable forms of EY in solvents of varying polarity. Theoretical Hansen solubility parameters and the COSMO-RS solvation model were applied to assess extraction efficiency. Hansen parameters were obtained via semiempirical PM7 calculations, while BP86/def2-TZVPD DFT computations were employed within the openCOSMO-RS framework. The developed method exhibited a linear calibration range between 0.1 and 130 µg·L−1, with a high correlation coefficient (R2 = 0.9982). The limit of detection (LOD) was established at 0.028 µg·L−1. Method precision and repeatability were confirmed over two days, with relative standard deviations (RSDs) ranging from 1.1% to 2.7% and with recoveries between 99.0% and 106.2%. The proposed analytical approach was successfully applied to the determination of EY in real water samples, demonstrating both its practical applicability and alignment with green chemistry principles.
Open AccessFluorimetric Determination of Eosin Y in Water Samples and Drinks Using Deep Eutectic Solvent-Based Liquid-Phase Microextraction
An environmentally friendly and highly sensitive analytical method for the determination of the dye Eosin Y (EY) was developed utilizing vortex-assisted liquid–liquid microextraction based on deep eutectic solvents (DESs), combined with fluorescence detection (LPME-FLD). The extraction efficiencies of conventional solvents and various DES systems, composed of tetrabutylammonium bromide (TBAB) and alcohols (hexanol, octanol, and decanol) in different ratios, were systematically compared. DFT calculations provided insights into the most stable forms of EY in solvents of varying polarity. Theoretical Hansen solubility parameters and the COSMO-RS solvation model were applied to assess extraction efficiency. Hansen parameters were obtained via semiempirical PM7 calculations, while BP86/def2-TZVPD DFT computations were employed within the openCOSMO-RS framework. The developed method exhibited a linear calibration range between 0.1 and 130 µg·L−1, with a high correlation coefficient (R2 = 0.9982). The limit of detection (LOD) was established at 0.028 µg·L−1. Method precision and repeatability were confirmed over two days, with relative standard deviations (RSDs) ranging from 1.1% to 2.7% and with recoveries between 99.0% and 106.2%. The proposed analytical approach was successfully applied to the determination of EY in real water samples, demonstrating both its practical applicability and alignment with green chemistry principles.
- Open Access
Fluorescence-Based Detection of Picric Acid Using Vortex-Assisted Liquid–Liquid Microextraction: An Innovative Analytical Approach
A novel design for vortex-assisted liquid–liquid microextraction (VALLME), combined with spectrofluorimetric determination (FLD), was proposed and successfully tested for determining picric acid (PA) in water samples. This fluorescence method is based on the formation of an ion associate (IA) through electrostatic interactions, which serves as the analytical species for fluorescence measurement in the presence of the basic polymethine dye Astrafloksin (AF). The approach aims to minimize the volume of the extraction phase, aligning with the principles of green analytical chemistry. The calibration curve was linear from 0.92 to 11.45 µg L−1, with an R2 of 0.9930. LOD was 0.40 µg L−1. Density functional theory (DFT) calculations, supported by analysis of van der Waals and electrostatic interionic attraction, helped explain the experimentally observed selectivity of the AF cation for picrate compared to other selected phenols. Theoretical solubility descriptors of the proposed IA provided insight into the extraction of IA from water to the n-amyl acetate phase. This VALLME-FLD method represents a significant advancement in PA determination, characterized by high sensitivity, selectivity, and procedural simplicity. It minimizes the use of organic solvents, facilitates direct sample preparation, and shortens analysis time. The developed method was successfully applied to real samples.
Open AccessFluorescence-Based Detection of Picric Acid Using Vortex-Assisted Liquid–Liquid Microextraction: An Innovative Analytical Approach
A novel design for vortex-assisted liquid–liquid microextraction (VALLME), combined with spectrofluorimetric determination (FLD), was proposed and successfully tested for determining picric acid (PA) in water samples. This fluorescence method is based on the formation of an ion associate (IA) through electrostatic interactions, which serves as the analytical species for fluorescence measurement in the presence of the basic polymethine dye Astrafloksin (AF). The approach aims to minimize the volume of the extraction phase, aligning with the principles of green analytical chemistry. The calibration curve was linear from 0.92 to 11.45 µg L−1, with an R2 of 0.9930. LOD was 0.40 µg L−1. Density functional theory (DFT) calculations, supported by analysis of van der Waals and electrostatic interionic attraction, helped explain the experimentally observed selectivity of the AF cation for picrate compared to other selected phenols. Theoretical solubility descriptors of the proposed IA provided insight into the extraction of IA from water to the n-amyl acetate phase. This VALLME-FLD method represents a significant advancement in PA determination, characterized by high sensitivity, selectivity, and procedural simplicity. It minimizes the use of organic solvents, facilitates direct sample preparation, and shortens analysis time. The developed method was successfully applied to real samples.
- Open Access
An Innovative Vortex-Assisted Liquid-Liquid Microextraction Approach Using Deep Eutectic Solvent: Application for the Spectrofluorometric Determination of Rhodamine B in Water, Food and Cosmetic Samples
A new green and highly sensitive method for the determination of rhodamine B (RhB) by deep eutectic solvent-based vortex-assisted liquid–liquid microextraction with fluorescence detection (DES-VALLME-FLD) was developed. The extraction efficiency of conventional solvents and different deep eutectic solvent (DES) systems composed of tetrabutylammonium bromide (TBAB) and an alcohol (hexanol, octanol, or decanol) in different ratios were compared. DFT calculations of intermolecular electrostatic and non-covalent interactions of the most stable RhB forms with DES and water explain the experimental DESs’ extraction efficiency. Semiempirical PM7 computations were used to obtain Hansen solubility parameters, which supported the good solubility of the monocationic RhB form in selected DESs. The dependence of the linear calibration of microextraction into 100 µL DES was observed in the RhB calibration range from 0.2 to 10.0 µg L−1 with a correlation coefficient of R2 = 0.9991. The LOD value was calculated to be 0.023 µg L−1. The accuracy and precision of the proposed method were verified over two days with RSD values of 2.9 to 4.1% and recovery of 94.6 to 103.7%. The developed method was applied to the determination of RhB in real samples (tap water, energy drink, and lipstick).
Open AccessAn Innovative Vortex-Assisted Liquid-Liquid Microextraction Approach Using Deep Eutectic Solvent: Application for the Spectrofluorometric Determination of Rhodamine B in Water, Food and Cosmetic Samples
A new green and highly sensitive method for the determination of rhodamine B (RhB) by deep eutectic solvent-based vortex-assisted liquid–liquid microextraction with fluorescence detection (DES-VALLME-FLD) was developed. The extraction efficiency of conventional solvents and different deep eutectic solvent (DES) systems composed of tetrabutylammonium bromide (TBAB) and an alcohol (hexanol, octanol, or decanol) in different ratios were compared. DFT calculations of intermolecular electrostatic and non-covalent interactions of the most stable RhB forms with DES and water explain the experimental DESs’ extraction efficiency. Semiempirical PM7 computations were used to obtain Hansen solubility parameters, which supported the good solubility of the monocationic RhB form in selected DESs. The dependence of the linear calibration of microextraction into 100 µL DES was observed in the RhB calibration range from 0.2 to 10.0 µg L−1 with a correlation coefficient of R2 = 0.9991. The LOD value was calculated to be 0.023 µg L−1. The accuracy and precision of the proposed method were verified over two days with RSD values of 2.9 to 4.1% and recovery of 94.6 to 103.7%. The developed method was applied to the determination of RhB in real samples (tap water, energy drink, and lipstick).