Xiang Lan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiang Lan has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Longfei Zhang
College of Architecture and Civil Engineering, Kunming University, Kunming 650214, China
5 shared publications - Kechuan Wu
College of Architecture and Civil Engineering, Kunming University, Kunming 650214, China
4 shared publications - Wenzheng Yu
College of Architecture and Civil Engineering, Kunming University, Kunming 650214, China
4 shared publications - Qiang Zhou
Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming 650500, China
3 shared publications - Wen Pan
Civil Engineering and Architecture Faculty, Kunming University of Science and Technology, Kunming, People’s Republic of China
3 shared publications - Baifeng Sun
China-Pakistan Belt and Road Joint Laboratory on Smart Disaster Prevention of Major Infrastructures, Southeast University, Nanjing 211189, China
2 shared publications
Latest Publications
- Open Access
An Analytical Model and Parameter Sensitivity Analysis of the Energy Dissipation Ratio for Nonlinear Viscous Dampers Under Seismic Excitation
This study investigates the energy dissipation efficiency of structures equipped with nonlinear viscous dampers under seismic excitation. It aims to address the lack of a clear quantitative relationship between the energy dissipation ratio (the ratio of energy dissipated by dampers to the total seismic input energy), ground motion intensity, and damper parameters by systematically examining the underlying energy dissipation mechanism and parameter influence laws. First, an analytical model for a single-degree-of-freedom (SDOF) system controlled by the nonlinear viscous damper is established based on random vibration theory. An explicit analytical formula for the energy dissipation ratio is then derived by incorporating the statistical properties of the velocity response, which reveals a power-law relationship with the peak ground acceleration (PGA), damping coefficient (C), and damping exponent (α). Subsequently, this analytical model is extended to multi-degree-of-freedom (MDOF) structures using the mode decomposition method, leading to an engineering-oriented approximate formula for the energy dissipation ratio under the assumption of first-mode dominance, with its applicability conditions specified. Finally, a six-story reinforced concrete frame is employed as a numerical case study to evaluate the accuracy and engineering applicability of the proposed model through nonlinear time history and sensitivity analyses under various damper parameter combinations. The results indicate that PGA, C, and α all have a significant impact on the energy dissipation ratio and structural response, with C exerting a more direct influence on the overall energy dissipation level. The energy dissipation ratio is demonstrated to be a key performance indicator for damper parameter selection and seismic performance evaluation, providing a theoretical basis and practical reference for the damping design of structures incorporating nonlinear viscous dampers.
Open AccessAn Analytical Model and Parameter Sensitivity Analysis of the Energy Dissipation Ratio for Nonlinear Viscous Dampers Under Seismic Excitation
This study investigates the energy dissipation efficiency of structures equipped with nonlinear viscous dampers under seismic excitation. It aims to address the lack of a clear quantitative relationship between the energy dissipation ratio (the ratio of energy dissipated by dampers to the total seismic input energy), ground motion intensity, and damper parameters by systematically examining the underlying energy dissipation mechanism and parameter influence laws. First, an analytical model for a single-degree-of-freedom (SDOF) system controlled by the nonlinear viscous damper is established based on random vibration theory. An explicit analytical formula for the energy dissipation ratio is then derived by incorporating the statistical properties of the velocity response, which reveals a power-law relationship with the peak ground acceleration (PGA), damping coefficient (C), and damping exponent (α). Subsequently, this analytical model is extended to multi-degree-of-freedom (MDOF) structures using the mode decomposition method, leading to an engineering-oriented approximate formula for the energy dissipation ratio under the assumption of first-mode dominance, with its applicability conditions specified. Finally, a six-story reinforced concrete frame is employed as a numerical case study to evaluate the accuracy and engineering applicability of the proposed model through nonlinear time history and sensitivity analyses under various damper parameter combinations. The results indicate that PGA, C, and α all have a significant impact on the energy dissipation ratio and structural response, with C exerting a more direct influence on the overall energy dissipation level. The energy dissipation ratio is demonstrated to be a key performance indicator for damper parameter selection and seismic performance evaluation, providing a theoretical basis and practical reference for the damping design of structures incorporating nonlinear viscous dampers.
- Open Access
Experimental Study on the Seismic Behavior of All-Steel Buckling-Restrained Braces Without an Unbonded Material Layer
Three all-steel buckling-restrained brace (ABRB) specimens without unbonded materials were designed and manufactured. Through low-cycle reciprocating load tests, the seismic performance of these buckling-restrained braces was investigated, and the influence of the absence of an unbonded layer on failure modes, energy dissipation capacity, and low-cycle fatigue life was examined. The research findings suggest that in all-steel buckling-restrained braces lacking an unbonded layer, the excessive friction between the energy dissipation unit and the restraining unit can, to a certain degree, increase local compressive stress. This makes the braces more susceptible to local buckling at the ends. The frictional effect causes the axial force of the ABRB to follow a distribution pattern where it is greater at the ends and smaller in the middle. Correspondingly, the buckling wavelength of the energy dissipation unit shows a pattern of being shorter at the ends and longer in the middle, which also results in a significant cyclic hardening phenomenon in the ABRB. The fatigue performance of the ABRB is inversely related to the amplitude of local buckling in the energy dissipation unit.
Open AccessExperimental Study on the Seismic Behavior of All-Steel Buckling-Restrained Braces Without an Unbonded Material Layer
Three all-steel buckling-restrained brace (ABRB) specimens without unbonded materials were designed and manufactured. Through low-cycle reciprocating load tests, the seismic performance of these buckling-restrained braces was investigated, and the influence of the absence of an unbonded layer on failure modes, energy dissipation capacity, and low-cycle fatigue life was examined. The research findings suggest that in all-steel buckling-restrained braces lacking an unbonded layer, the excessive friction between the energy dissipation unit and the restraining unit can, to a certain degree, increase local compressive stress. This makes the braces more susceptible to local buckling at the ends. The frictional effect causes the axial force of the ABRB to follow a distribution pattern where it is greater at the ends and smaller in the middle. Correspondingly, the buckling wavelength of the energy dissipation unit shows a pattern of being shorter at the ends and longer in the middle, which also results in a significant cyclic hardening phenomenon in the ABRB. The fatigue performance of the ABRB is inversely related to the amplitude of local buckling in the energy dissipation unit.
- Open Access
Experimental Study on the Seismic Performance of Buckling-Restrained Braces with Different Lengths
To investigate the differences in seismic performance of buckling-restrained braces (BRBs) with significantly different lengths and to explore the influence of length on the energy dissipation efficiency of BRBs within the same structure, this study designed and fabricated two BRBs with lengths of 8.5 m and 3 m based on an actual engineering project. Low-cycle reciprocating load tests were conducted to compare the performance of the two BRBs in terms of hysteretic energy dissipation capacity, tension–compression bearing capacity imbalance coefficient, cumulative plastic deformation capacity, and low-cycle fatigue life. Additionally, the energy dissipation and damping efficiency of BRBs of different lengths within the same structure was analyzed. The results indicate that under cyclic loading based on design displacement, the 8.5 m BRB exhibits a greater equivalent viscous damping ratio, cumulative hysteretic energy dissipation, and cumulative plastic deformation, leading to more efficient energy dissipation and damping effects. The length of the brace is a significant factor affecting the imbalance coefficient of tension–compression bearing capacity, with longer braces resulting in a larger imbalance coefficient. The 3 m BRB shows less deviation from the mean values of various fatigue parameters, indicating more stable low-cycle fatigue performance. Within the same structure, shorter BRBs with larger design displacements achieve higher energy dissipation efficiency, allowing for more effective utilization of their energy dissipation capacity. This study’s conclusions provide valuable references for designers in the rational selection of BRBs of different lengths in actual engineering projects and offer preliminary insights into the energy dissipation efficiency of BRBs of varying lengths within a structure.
Open AccessExperimental Study on the Seismic Performance of Buckling-Restrained Braces with Different Lengths
To investigate the differences in seismic performance of buckling-restrained braces (BRBs) with significantly different lengths and to explore the influence of length on the energy dissipation efficiency of BRBs within the same structure, this study designed and fabricated two BRBs with lengths of 8.5 m and 3 m based on an actual engineering project. Low-cycle reciprocating load tests were conducted to compare the performance of the two BRBs in terms of hysteretic energy dissipation capacity, tension–compression bearing capacity imbalance coefficient, cumulative plastic deformation capacity, and low-cycle fatigue life. Additionally, the energy dissipation and damping efficiency of BRBs of different lengths within the same structure was analyzed. The results indicate that under cyclic loading based on design displacement, the 8.5 m BRB exhibits a greater equivalent viscous damping ratio, cumulative hysteretic energy dissipation, and cumulative plastic deformation, leading to more efficient energy dissipation and damping effects. The length of the brace is a significant factor affecting the imbalance coefficient of tension–compression bearing capacity, with longer braces resulting in a larger imbalance coefficient. The 3 m BRB shows less deviation from the mean values of various fatigue parameters, indicating more stable low-cycle fatigue performance. Within the same structure, shorter BRBs with larger design displacements achieve higher energy dissipation efficiency, allowing for more effective utilization of their energy dissipation capacity. This study’s conclusions provide valuable references for designers in the rational selection of BRBs of different lengths in actual engineering projects and offer preliminary insights into the energy dissipation efficiency of BRBs of varying lengths within a structure.
- Open Access
- 29 August 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (17) , 7627
A Study on the Amplification Effect and Optimum Control of the Intermediate Column–Lever Negative Stiffness Viscous Damper
Currently, the energy dissipation efficiency of intermediate column dampers is extremely low, and traditional lever amplification damping systems occupy a large space in buildings. Aiming at solving these problems, this paper puts forward a new intermediate column–lever negative stiffness viscous damper (CLNVD), which has the characteristics of small impact on building space and significant amplification of the damper displacement. The CLNVD consists of the following four parts: the viscous damper, the negative stiffness device, the lever, and the intermediate column. This paper introduces the displacement amplification coefficient (fd) to assess the CLNVD’s displacement amplification effect and introduces the energy dissipation coefficient (fE) to assess the CLNVD’s energy dissipation effect. The expressions for fd and fE are derived according to the geometric magnification coefficient and effective displacement factor. Moreover, the impacts of multiple factors including the CLNVD’s position, the lever’s amplification coefficient, the bending line stiffness of beam, the negative stiffness, the damping coefficient, the damping index, and the inter-story displacement on the CLNVD’s fd and fE are elaborated. The analysis results reveal the following: when the CLNVD is located in the middle of the span, the fd and fE of the CLNVD will be maximized, and fE will increase first and then decrease as the beam’s bending line stiffness increases. Meanwhile, the amplification capability of the CLNVD increases as the lever’s amplification coefficient χ rises. When the negative stiffness does not exist, there exists an optimum lever’s amplification coefficient χ that maximizes fE. When the combination of damping coefficient c and index α satisfies a specific relationship, fE of the CLNVD reaches its largest value. When the negative stiffness and the loss stiffness of VD are within the region proposed in this paper, the CLNVD will achieve a higher fd and avoid providing significant negative stiffness. Subsequently, this paper proposes an optimization design method of the CLNVD. Finally, the amplification effect of CLNVD as well as the effectiveness of its optimization design method are verified through examples. In the case study, the CLNVD offers a larger damping ratio under the circumstance of fortification earthquakes. Under fortification and rare earthquakes, the inter-story displacement of Scheme 1 has been decreased by half roughly. According to the above-mentioned results, the CLNVD provides a brand-new approach for designers in the seismic design of buildings. Furthermore, this paper will provide beneficial reference for the damping design of other amplification devices equipped with negative stiffness dampers.
- 29 August 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (17) , 7627
Open AccessA Study on the Amplification Effect and Optimum Control of the Intermediate Column–Lever Negative Stiffness Viscous Damper
Currently, the energy dissipation efficiency of intermediate column dampers is extremely low, and traditional lever amplification damping systems occupy a large space in buildings. Aiming at solving these problems, this paper puts forward a new intermediate column–lever negative stiffness viscous damper (CLNVD), which has the characteristics of small impact on building space and significant amplification of the damper displacement. The CLNVD consists of the following four parts: the viscous damper, the negative stiffness device, the lever, and the intermediate column. This paper introduces the displacement amplification coefficient (fd) to assess the CLNVD’s displacement amplification effect and introduces the energy dissipation coefficient (fE) to assess the CLNVD’s energy dissipation effect. The expressions for fd and fE are derived according to the geometric magnification coefficient and effective displacement factor. Moreover, the impacts of multiple factors including the CLNVD’s position, the lever’s amplification coefficient, the bending line stiffness of beam, the negative stiffness, the damping coefficient, the damping index, and the inter-story displacement on the CLNVD’s fd and fE are elaborated. The analysis results reveal the following: when the CLNVD is located in the middle of the span, the fd and fE of the CLNVD will be maximized, and fE will increase first and then decrease as the beam’s bending line stiffness increases. Meanwhile, the amplification capability of the CLNVD increases as the lever’s amplification coefficient χ rises. When the negative stiffness does not exist, there exists an optimum lever’s amplification coefficient χ that maximizes fE. When the combination of damping coefficient c and index α satisfies a specific relationship, fE of the CLNVD reaches its largest value. When the negative stiffness and the loss stiffness of VD are within the region proposed in this paper, the CLNVD will achieve a higher fd and avoid providing significant negative stiffness. Subsequently, this paper proposes an optimization design method of the CLNVD. Finally, the amplification effect of CLNVD as well as the effectiveness of its optimization design method are verified through examples. In the case study, the CLNVD offers a larger damping ratio under the circumstance of fortification earthquakes. Under fortification and rare earthquakes, the inter-story displacement of Scheme 1 has been decreased by half roughly. According to the above-mentioned results, the CLNVD provides a brand-new approach for designers in the seismic design of buildings. Furthermore, this paper will provide beneficial reference for the damping design of other amplification devices equipped with negative stiffness dampers.
- Open Access
Theoretical Research and Shaking Table Test on Nominal Aspect Ratio of the Isolated Step-Terrace Structure
With the installation of rubber isolation bearings in the upper and lower ground layers, an isolated step-terrace structure was created. Considering the ultimate bearing capacity of the rubber bearing under tension as the critical condition, a comprehensive framework was established to evaluate the overturning failure mechanisms present in isolated step-terrace structures. The bound of nominal aspect ratio was identified as the principal control index within this framework, which incorporates critical parameters such as height ratio (α), width ratio (β), vertical tensile stiffness to compressive stiffness ratio (γ), seismic coefficient (k), and nominal vertical compressive stress (σ0) to provide a thorough analysis of the structural responses and potential failure scenarios. In order to further investigate this matter, a scaled model of an isolated step-terrace concrete frame structure featuring two dropped layers and a single span within an 8° seismic fortification zone was meticulously crafted at a 1:10 similarity ratio. Subsequently, a series of shaking table tests were conducted to analyze the structural response under seismic excitation. The findings indicate that: utilizing the bound of nominal aspect ratio as a metric to gauge the anti-overturning capacity of isolated step-terrace structures is a justified approach. In instances where the height ratio remains constant, the bound of nominal aspect ratio for both positive and negative overturning trended upward with an increase in the width ratio. Notably, the bound of nominal aspect ratio for positive overturning consistently registered lower values compared to that of the negative overturning, underscoring the heightened susceptibility of step-terrace structures to positive overturning. Moreover, in scenarios characterized by higher height and width ratios, the structural integrity remained unscathed by any overturning effects arising from insufficient tensile strength in rubber bearings. Furthermore, the bound of nominal aspect ratio exhibited an ascending trend as the seismic coefficient, nominal vertical compressive stress, and vertical tensile stiffness to compressive stiffness ratio decreased. The outcomes derived from the shaking table test not only confirm the impressive seismic performance of the structure, but also, by closely examining the instantaneous stress variations within the upper and lower isolation layers of the model, substantiate the existence of a positive overturning hazard in scenarios marked by higher seismic coefficients (k). This observation aligns seamlessly with the theoretical projections, thereby substantiating the efficacy of the structural overturning failure theory through direct empirical verification.
Open AccessTheoretical Research and Shaking Table Test on Nominal Aspect Ratio of the Isolated Step-Terrace Structure
With the installation of rubber isolation bearings in the upper and lower ground layers, an isolated step-terrace structure was created. Considering the ultimate bearing capacity of the rubber bearing under tension as the critical condition, a comprehensive framework was established to evaluate the overturning failure mechanisms present in isolated step-terrace structures. The bound of nominal aspect ratio was identified as the principal control index within this framework, which incorporates critical parameters such as height ratio (α), width ratio (β), vertical tensile stiffness to compressive stiffness ratio (γ), seismic coefficient (k), and nominal vertical compressive stress (σ0) to provide a thorough analysis of the structural responses and potential failure scenarios. In order to further investigate this matter, a scaled model of an isolated step-terrace concrete frame structure featuring two dropped layers and a single span within an 8° seismic fortification zone was meticulously crafted at a 1:10 similarity ratio. Subsequently, a series of shaking table tests were conducted to analyze the structural response under seismic excitation. The findings indicate that: utilizing the bound of nominal aspect ratio as a metric to gauge the anti-overturning capacity of isolated step-terrace structures is a justified approach. In instances where the height ratio remains constant, the bound of nominal aspect ratio for both positive and negative overturning trended upward with an increase in the width ratio. Notably, the bound of nominal aspect ratio for positive overturning consistently registered lower values compared to that of the negative overturning, underscoring the heightened susceptibility of step-terrace structures to positive overturning. Moreover, in scenarios characterized by higher height and width ratios, the structural integrity remained unscathed by any overturning effects arising from insufficient tensile strength in rubber bearings. Furthermore, the bound of nominal aspect ratio exhibited an ascending trend as the seismic coefficient, nominal vertical compressive stress, and vertical tensile stiffness to compressive stiffness ratio decreased. The outcomes derived from the shaking table test not only confirm the impressive seismic performance of the structure, but also, by closely examining the instantaneous stress variations within the upper and lower isolation layers of the model, substantiate the existence of a positive overturning hazard in scenarios marked by higher seismic coefficients (k). This observation aligns seamlessly with the theoretical projections, thereby substantiating the efficacy of the structural overturning failure theory through direct empirical verification.
- Open Access
Study on Vibration Reduction Effect of the Building Structure Equipped with Intermediate Column–Lever Viscous Damper
Generally speaking, the traditional lever amplification damping system is installed between adjacent columns in a building, which occupies a significant amount of space in the building. In contrast to amplification devices in different forms, the damper displacement of the intermediate column damper system is smaller, and the vibration reduction efficiency is lower. In light of these drawbacks, this study proposes a new amplification device for energy dissipation and vibration reduction, which is based on an intermediate column–lever mechanism with a viscous damper (CLVD). Initially, a specific simplified mechanical model of CLVD is derived. Subsequently, an equivalent Kelvin mechanical model of CLVD is derived to intuitively reflect CLVD’s damping and stiffness effect. The damping ratio added by CLVDs to the structure is calculated according to that model; the additional damping ratio and additional stiffness are utilized to calculate the displacement ratio Rd and shear force ratio Rv of the structure with CLVDs to the structure without CLVDs. Rd and Rv are introduced to evaluate the vibration reduction effect of the structure with CLVDs, and the effects of various parameters (such as intermediate column position, beam’s bending line stiffness, lever amplification factor, damping coefficient, and earthquake intensity) on Rd and Rv are analyzed. The results indicate that when the ratio of the distance from the intermediate column to the edge column to the span of the beam is 0.5, CLVD owns the optimal vibration reduction effect. Increasing the beam’s bending line stiffness is beneficial for CLVD to control structural displacement and shear force; when the leverage amplification factor is too large, the CLVD provides the structure with stiffness as the main factor, followed by damping. Additionally, when the ratio of the displacement amplification factor to the geometric amplification factor satisfies fd/γ = 1/21−0.5α, the CLVD has the optimal displacement control effect on the structure. After that, measures are provided to optimize the CLVD in different situations in order to effectively control the inter-story displacement and the story shear force of the structure. Consequently, a nine-story frame is taken as an example to elaborate the application of CLVDs in the design for energy dissipation and vibration reduction. The results reveal that the CLVD scheme adopting the proposed optimization method can effectively enhance the displacement amplification ability of CLVDs, resulting in an additional damping ratio of up to 12%. At the same time, the inter-story displacement was reduced by almost 40% under fortification earthquakes. Through the research in this study, designers can obtain a new choice in structural vibration reduction design.
Open AccessStudy on Vibration Reduction Effect of the Building Structure Equipped with Intermediate Column–Lever Viscous Damper
Generally speaking, the traditional lever amplification damping system is installed between adjacent columns in a building, which occupies a significant amount of space in the building. In contrast to amplification devices in different forms, the damper displacement of the intermediate column damper system is smaller, and the vibration reduction efficiency is lower. In light of these drawbacks, this study proposes a new amplification device for energy dissipation and vibration reduction, which is based on an intermediate column–lever mechanism with a viscous damper (CLVD). Initially, a specific simplified mechanical model of CLVD is derived. Subsequently, an equivalent Kelvin mechanical model of CLVD is derived to intuitively reflect CLVD’s damping and stiffness effect. The damping ratio added by CLVDs to the structure is calculated according to that model; the additional damping ratio and additional stiffness are utilized to calculate the displacement ratio Rd and shear force ratio Rv of the structure with CLVDs to the structure without CLVDs. Rd and Rv are introduced to evaluate the vibration reduction effect of the structure with CLVDs, and the effects of various parameters (such as intermediate column position, beam’s bending line stiffness, lever amplification factor, damping coefficient, and earthquake intensity) on Rd and Rv are analyzed. The results indicate that when the ratio of the distance from the intermediate column to the edge column to the span of the beam is 0.5, CLVD owns the optimal vibration reduction effect. Increasing the beam’s bending line stiffness is beneficial for CLVD to control structural displacement and shear force; when the leverage amplification factor is too large, the CLVD provides the structure with stiffness as the main factor, followed by damping. Additionally, when the ratio of the displacement amplification factor to the geometric amplification factor satisfies fd/γ = 1/21−0.5α, the CLVD has the optimal displacement control effect on the structure. After that, measures are provided to optimize the CLVD in different situations in order to effectively control the inter-story displacement and the story shear force of the structure. Consequently, a nine-story frame is taken as an example to elaborate the application of CLVDs in the design for energy dissipation and vibration reduction. The results reveal that the CLVD scheme adopting the proposed optimization method can effectively enhance the displacement amplification ability of CLVDs, resulting in an additional damping ratio of up to 12%. At the same time, the inter-story displacement was reduced by almost 40% under fortification earthquakes. Through the research in this study, designers can obtain a new choice in structural vibration reduction design.
- Open Access
Analysis of Amplification Effect and Optimal Control of the Toggle-Style Negative Stiffness Viscous Damper
This paper proposes a new toggle-style negative stiffness viscous damper (TNVD), and evaluates the performance of the TNVD with the displacement amplification factor (fd) and the energy dissipation factor (fE). Firstly, the composition and characteristics of the TNVD are introduced. Subsequently, the displacement amplification factor is introduced to evaluate the displacement amplification ability of the TNVD, and it is decomposed into a geometric amplification factor and an effective displacement coefficient. Then, based on the geometric amplification factor and effective displacement coefficient, the correlation between the TNVD’s displacement amplification ability and inter-story deformation is studied, and an improved TNVD is proposed. By the comparison of the finite element calculation results, it is found that the improved TNVD can utilize the assumption of small structural deformation. After that, the impacts of plentiful aspects, such as the length of the lower connecting rod, the horizontal inclination angle of the lower connecting rod, the inter-story deformation limit, the cross-sectional area of the connecting rod, the damping coefficient, and the negative stiffness on the fd and fE of the improved TNVD, are expounded. The research results show that when the length of the TNVD’s lower connecting rod remains unchanged, the fd and fE present a trend of increasing first and then decreasing with the increase in the horizontal inclination angle of the lower connecting rod. When the inter-story deformation is fixed, there exists an optimal lower connecting rod’s length that satisfies a specific relationship to achieve the optimal geometric amplification factor of the TNVD. By adjusting the damping parameters of the TNVD, we can obtain a better effective displacement coefficient greater than 0.95 in the proposed target region. Meanwhile, the fd and fE increase with the decrease in the negative stiffness. An optimization strategy for the improved TNVD has been proposed to ensure that the TNVD has the characteristics of operational safety, ideal displacement amplification capability, and energy dissipation capability. Furthermore, a multi-objective control design method with an additional improved TNVD structure is proposed. The vibration reduction effect of the structure with the improved TNVD and the effectiveness of the optimization strategy are verified through examples.
Open AccessAnalysis of Amplification Effect and Optimal Control of the Toggle-Style Negative Stiffness Viscous Damper
This paper proposes a new toggle-style negative stiffness viscous damper (TNVD), and evaluates the performance of the TNVD with the displacement amplification factor (fd) and the energy dissipation factor (fE). Firstly, the composition and characteristics of the TNVD are introduced. Subsequently, the displacement amplification factor is introduced to evaluate the displacement amplification ability of the TNVD, and it is decomposed into a geometric amplification factor and an effective displacement coefficient. Then, based on the geometric amplification factor and effective displacement coefficient, the correlation between the TNVD’s displacement amplification ability and inter-story deformation is studied, and an improved TNVD is proposed. By the comparison of the finite element calculation results, it is found that the improved TNVD can utilize the assumption of small structural deformation. After that, the impacts of plentiful aspects, such as the length of the lower connecting rod, the horizontal inclination angle of the lower connecting rod, the inter-story deformation limit, the cross-sectional area of the connecting rod, the damping coefficient, and the negative stiffness on the fd and fE of the improved TNVD, are expounded. The research results show that when the length of the TNVD’s lower connecting rod remains unchanged, the fd and fE present a trend of increasing first and then decreasing with the increase in the horizontal inclination angle of the lower connecting rod. When the inter-story deformation is fixed, there exists an optimal lower connecting rod’s length that satisfies a specific relationship to achieve the optimal geometric amplification factor of the TNVD. By adjusting the damping parameters of the TNVD, we can obtain a better effective displacement coefficient greater than 0.95 in the proposed target region. Meanwhile, the fd and fE increase with the decrease in the negative stiffness. An optimization strategy for the improved TNVD has been proposed to ensure that the TNVD has the characteristics of operational safety, ideal displacement amplification capability, and energy dissipation capability. Furthermore, a multi-objective control design method with an additional improved TNVD structure is proposed. The vibration reduction effect of the structure with the improved TNVD and the effectiveness of the optimization strategy are verified through examples.
- Open Access
Study on the Damping Efficiency of a Structure with Additional Viscous Dampers Based on the Shaking Table Test
This study specifically focuses on the damping efficiency of a damped structure with additional viscous dampers. A two-layer steel frame structure with eight sets of viscous dampers is used to conduct a series of seismic simulation shaking table tests, including a non-damped structure without dampers and two damped structures with dampers placed at 1/2 and 1/6 of the beam span, respectively. By conducting these tests, the energy dissipation, force, and displacement of the damper, as well as the parameters of the structure such as floor displacement and acceleration, are obtained. The main damping efficiency indicators of the damped structure are calculated, including the additional damping ratio, inter-story displacement utilization rate, as well as the reduction rate of the vertex displacement and the base shear relative to the non-damped structure. The study shows that the viscous dampers exhibit full hysteresis loops and a strong energy dissipation capacity in the structure. The seismic response of the vertex displacement and base shear in the damped structure is significantly smaller than that in the non-damped structure. Under different seismic levels, including frequent earthquakes, occasional earthquakes, and rare earthquakes, the damping effect of the dampers placed at 1/2 of the beam span is significantly better than that placed at 1/6 of the beam span. For example, the additional damping ratio for the X-direction artificial wave REN is 19% and 11%, 20% and 13%, and 13% and 11%, respectively. The patterns for inter-story displacement utilization ratio, reduction rate of the vertex displacement, and reduction rate of the base shear are similar. The research findings strongly indicate that the damped structure with additional viscous dampers exhibits excellent damping efficiency. In future damping design, designers need to fully consider the placement of viscous dampers within the beam span.
Open AccessStudy on the Damping Efficiency of a Structure with Additional Viscous Dampers Based on the Shaking Table Test
This study specifically focuses on the damping efficiency of a damped structure with additional viscous dampers. A two-layer steel frame structure with eight sets of viscous dampers is used to conduct a series of seismic simulation shaking table tests, including a non-damped structure without dampers and two damped structures with dampers placed at 1/2 and 1/6 of the beam span, respectively. By conducting these tests, the energy dissipation, force, and displacement of the damper, as well as the parameters of the structure such as floor displacement and acceleration, are obtained. The main damping efficiency indicators of the damped structure are calculated, including the additional damping ratio, inter-story displacement utilization rate, as well as the reduction rate of the vertex displacement and the base shear relative to the non-damped structure. The study shows that the viscous dampers exhibit full hysteresis loops and a strong energy dissipation capacity in the structure. The seismic response of the vertex displacement and base shear in the damped structure is significantly smaller than that in the non-damped structure. Under different seismic levels, including frequent earthquakes, occasional earthquakes, and rare earthquakes, the damping effect of the dampers placed at 1/2 of the beam span is significantly better than that placed at 1/6 of the beam span. For example, the additional damping ratio for the X-direction artificial wave REN is 19% and 11%, 20% and 13%, and 13% and 11%, respectively. The patterns for inter-story displacement utilization ratio, reduction rate of the vertex displacement, and reduction rate of the base shear are similar. The research findings strongly indicate that the damped structure with additional viscous dampers exhibits excellent damping efficiency. In future damping design, designers need to fully consider the placement of viscous dampers within the beam span.
- Open Access
Tests and Seismic Response Analysis of Guided-Rail-Type Anti-Tensile Rubber Bearing
When subjected to seismic activity, tall isolated buildings with a high aspect ratio are susceptible to overturning as a result of the failure of rubber isolation bearings under tension. In order to address this issue, a guided-rail tension device (GR) has been developed to enhance the tensile strength of rubber bearings. Furthermore, a novel guided-rail isolation rubber bearing (GR&RB) has been proposed as a potential solution. Quasi-static tests have been conducted to investigate the mechanical properties of the GR, as well as the GR&LNR600 and LNR600. Additionally, numerical finite element analysis has been employed to study the seismic response of the GR&RB under El Centro seismic action in a high-rise building with an aspect ratio of approximately 4. The experimental results suggest that the inclusion of GRs has a limited effect on the horizontal mechanical attributes of rubber isolation bearings. Nevertheless, it simultaneously enhances their tensile strength, demonstrating a significant augmentation of 4.23 times. Moreover, the mechanical behavior of the GR aligns with the Hook model. The numerical analysis suggests that the utilization of GR&RB can mitigate the tensile stress levels of rubber isolators. Furthermore, it is recommended to augment the elastic tensile stiffness of the GR while reducing the open value to enhance the tensile efficiency, with the potential to attain up to 75% efficiency in tensile performance.
Open AccessTests and Seismic Response Analysis of Guided-Rail-Type Anti-Tensile Rubber Bearing
When subjected to seismic activity, tall isolated buildings with a high aspect ratio are susceptible to overturning as a result of the failure of rubber isolation bearings under tension. In order to address this issue, a guided-rail tension device (GR) has been developed to enhance the tensile strength of rubber bearings. Furthermore, a novel guided-rail isolation rubber bearing (GR&RB) has been proposed as a potential solution. Quasi-static tests have been conducted to investigate the mechanical properties of the GR, as well as the GR&LNR600 and LNR600. Additionally, numerical finite element analysis has been employed to study the seismic response of the GR&RB under El Centro seismic action in a high-rise building with an aspect ratio of approximately 4. The experimental results suggest that the inclusion of GRs has a limited effect on the horizontal mechanical attributes of rubber isolation bearings. Nevertheless, it simultaneously enhances their tensile strength, demonstrating a significant augmentation of 4.23 times. Moreover, the mechanical behavior of the GR aligns with the Hook model. The numerical analysis suggests that the utilization of GR&RB can mitigate the tensile stress levels of rubber isolators. Furthermore, it is recommended to augment the elastic tensile stiffness of the GR while reducing the open value to enhance the tensile efficiency, with the potential to attain up to 75% efficiency in tensile performance.
- Open Access
Study on the Influence and Optimization Design of Viscous Damper Parameters on the Damping Efficiency of Frame Shear Wall Structure
This study investigates the influence of viscous damper parameters on the damping efficiency of frame shear wall structures. Taking a specific frame shear wall structure as the background, a three-dimensional finite element model is established using a nonlinear dynamic time–history analysis method. The damping ratio, reduction in vertex displacement, reduction in base shear, and inter-story drift utilization rate are selected as the damping performance indicators. Firstly, a sensitivity analysis is conducted to study the influence of different viscous damper parameters on these indicators. Then, the relationship models between the viscous damper parameters and the indicators are fitted using the response surface method, and the fitting effect is evaluated through an F-test and determination coefficient R2. Finally, an objective function based on key damping performance indicators is established to solve for the optimal parameters. The results show that the traditional sensitivity analysis method is unable to comprehensively consider the combined effects of different damping efficiency indicators. The response surface method has high fitting accuracy and good predictability and can serve as an optimization model. Considering the stiffness of supporting components matched with the viscous damper parameters, the feasibility of the optimal damping parameters is demonstrated from an engineering application perspective. A simple and easy-to-operate damping design flowchart is proposed, providing important guidance and reference for designers in frame shear wall structure damping design in the future.
Open AccessStudy on the Influence and Optimization Design of Viscous Damper Parameters on the Damping Efficiency of Frame Shear Wall Structure
This study investigates the influence of viscous damper parameters on the damping efficiency of frame shear wall structures. Taking a specific frame shear wall structure as the background, a three-dimensional finite element model is established using a nonlinear dynamic time–history analysis method. The damping ratio, reduction in vertex displacement, reduction in base shear, and inter-story drift utilization rate are selected as the damping performance indicators. Firstly, a sensitivity analysis is conducted to study the influence of different viscous damper parameters on these indicators. Then, the relationship models between the viscous damper parameters and the indicators are fitted using the response surface method, and the fitting effect is evaluated through an F-test and determination coefficient R2. Finally, an objective function based on key damping performance indicators is established to solve for the optimal parameters. The results show that the traditional sensitivity analysis method is unable to comprehensively consider the combined effects of different damping efficiency indicators. The response surface method has high fitting accuracy and good predictability and can serve as an optimization model. Considering the stiffness of supporting components matched with the viscous damper parameters, the feasibility of the optimal damping parameters is demonstrated from an engineering application perspective. A simple and easy-to-operate damping design flowchart is proposed, providing important guidance and reference for designers in frame shear wall structure damping design in the future.