    Using collimator rotation to retain conformal dose distributions with thicker MLC leaves

    by Joseph John Bateman, Richard P Hugtenburg, Alexander Christie, Rajesh Jena, Manjit Dosanjh

    The multi-leaf collimator (MLC) is a critical component of modern X-ray radiotherapy systems which allows for the delivery of a conformal dose distribution to the tumour. However, MLCs are one of the most sensitive components in a linac since they contain several components that are prone to failure. The current trend in design is to produce MLCs with ever-increasing numbers of leaves to improve their ability to shape the beam, but this further reduces their robustness. This robustness has shown to be an important factor in low- and middle-income countries (LMICs) where there are currently limited numbers of available linacs per person and that linac downtime has a much greater impact on treatment capacity than in high-income countries. In investigating designs for a more robust MLC system, we assess a new method to deliver a similar conformal tumour dose distribution using a significantly simplified MLC with thicker leaves whilst utilising multiple collimator angles for each delivery to attempt to retain excellent conformity of the dose. The open-source treatment planning software, matRad, was used to generate representative treatment plans to compare the conformity index, homogeneity index and mean dose delivered to circular and crescent-shaped targets for a range of MLC leaf thicknesses and collimator angles. Using MLCs with a leaf thickness of up to 1.5 cm thickness, it was possible to increase the dose conformity by using between 2 to 6 different collimators angles to deliver multiple x-ray beams and generate a conformal treatment plan for a crescent-shaped target (CI > 0.6) with a single dose distribution. Using this technique of delivering the beam from multiple collimator angles, linacs with more robust, thicker and fewer-leaved MLCs can still achieve excellent conformal dose distributions. Such a technique likely can achieve even greater conformity in step-and-shoot intensity modulated radiotherapy (IMRT).

  • Open Access

    Monte Carlo and film dosimetry study of collimator effects on penumbra and out-of-field dose for very high-energy electrons

    by Jade Fischer, Antonio Gilardi, Alexander Malyzhenkov, Pierre Korysko, Alexander J Hart, Vilde Rieker, Joseph John Bateman, Wilfrid Farabolini, Roberto Corsini, Manjit Dosanjh, et al.

    Objective: Very high-energy electrons (VHEEs) offer deep penetration, low scattering, and the potential for ultra-high dose rate (UHDR) delivery, making them promising candidates for future radiotherapy. However, the collimation of VHEE beams to achieve sharp beam penumbra remains poorly characterized. This study experimentally and computationally investigates how collimator material, thickness, and beam characteristics affect penumbra and leakage dose for VHEEs and establishes an initial foundation for the design of clinically feasible VHEE collimators. Approach: Tungsten, lead, and brass 5-mm diameter collimators were evaluated using film dosimetry with a 200 MeV electron beam delivered at the CERN Linear Electron Accelerator for Research (CLEAR) and validated through Monte Carlo simulations. Experimental measurements of penumbra and leakage were compared with simulations that systematically varied material (tungsten, lead, brass), thickness (2-8 cm), and beam energy (150-250 MeV). Additional sensitivity tests quantified the impact of beam instability on field shaping. Main results: For measurements in air, penumbrae increased linearly with distance from the collimator and was smallest for tungsten. Leakage dose decreased with increasing thickness, falling below 0.5% for a 40-mm thick tungsten collimator. Brass exhibited the highest leakage (up to 4.8%) and broadest penumbra. Monte Carlo models reproduced experimental trends within 5% for penumbrae but underestimated leakage, particularly for brass. The simulations indicated that VHEE beam divergence, beam size and collimator misalignment strongly influence beam penumbra and leakage. Significance: The presented work demonstrates that collimator material and geometry play a critical role in defining VHEE beam quality. Tungsten provided optimal attenuation and sharpness compared to brass and lead. These results establish quantitative benchmarks for VHEE collimator design and emphasize the importance of beam stability.

  • Open Access

    Radiation damage and recovery of plastic scintillators under ultra-high dose rate 200 MeV electrons at CERN CLEAR facility

    by Cloé Giguère, Alexander Hart, Joseph Bateman, Pierre Korysko, Wilfrid Farabolini, Yoan LeChasseur, Magdalena Bazalova-Carter, Luc Beaulieu

    Objective. The FLASH effect holds significant potential in improving radiotherapy treatment outcomes. Very high energy electrons (VHEEs) with energies in the range of 50–250 MeV can effectively target tumors deep in the body and can be accelerated to achieve ultra-high dose rates (UHDR), making them a promising modality for delivering FLASH radiotherapy in the clinic. However, apart from suitable VHEE sources, clinical translation requires accurate dosimetry, which is challenging due to the limitation of standard dosimeters under UHDR conditions. In this study, water-equivalent and real-time plastic scintillation dosimeters (PSDs) are tested to evaluate their viability for FLASH VHEE dosimetry. Approach. A 4-channel PSD, consisting of polystyrene-based BCF12 and Medscint proprietary scintillators, polyvinyltoluene-based EJ-212 and a blank plastic fiber channel for Cherenkov subtraction was exposed to the 200 MeV VHEE UHDR beam at the CLEAR CERN facility. The Hyperscint RP200 platform was used to assess linearity to dose pulses of up to 90 Gy and dose rates up to 4.6 × 10 9 Gy s−1, and to investigate radiation damage and recovery after dose accumulation of 37.2 kGy. Main results. While blank fiber response was linear across the entire dose range studied, light output saturated above 45 Gy/pulse for scintillators. Despite radiation damage, linearity was preserved, though it resulted in a decrease of scintillator and blank fiber light output of < 1.87%/kGy and a shift in spectra towards longer wavelengths. Short-term recovery ( < 100 h) of these changes was observed and depended on rest duration and accumulated dose. After long-term rest ( < 172 days), light output recovery was partial, with 6%–22% of residual permanent damage remaining, while spectral recovery was complete. Significance. We showed that PSDs are sensitive to radiation damage, but maintain dose linearity even after a total accumulated dose of 37.2 kGy, and exhibit significant response recovery. This work highlights the potential of PSDs for dosimetry in UHDR conditions.


  • Open Access

    Spatially fractionated radiotherapy with very high energy electron pencil beam scanning

    by Jade Fischer, Alexander Hart, Nicole Bedriová, Deae-Eddine Krim, Nathan Clements, Joseph Bateman, Pierre Korysko, Wilfrid Farabolini, Vilde Rieker, Roberto Corsini, et al.

    Objective. To evaluate spatially fractionated radiation therapy (SFRT) for very-high-energy electrons (VHEEs) delivered with pencil beam scanning. Approach. Radiochromic film was irradiated at the CERN linear electron accelerator for research using 194 MeV electrons with a step-and-shoot technique, moving films within a water tank. Peak-to-valley dose ratios (PVDRs), depths of convergence (PVDR ⩽ 1.1), peak doses, and valley doses assessed SFRT dose distribution quality. A Monte Carlo (MC) model of the pencil beams was developed using TOPAS and applied to a five-beam VHEE SFRT treatment for a canine glioma patient, compared to a clinical 6 MV VMAT plan. The plans were evaluated based on dose-volume histograms, mean dose, and maximum dose to the planning target volume (PTV) and organs at risks (OARs). Main results. Experimental PVDR values were maximized at 15.5 ± 0.1 at 12 mm depth for 5 mm spot spacing. A DOC of 76.5, 70.7, and 56.6 mm was found for 5, 4, and 3 mm beamlet spacings, respectively. MC simulations and experiments showed good agreement, with maximum relative dose differences of 2% in percentage depth dose curves and less than 3% in beam profiles. Simulated PVDR values reached 180 ± 4, potentially achievable with reduced leakage dose. VHEE SFRT plans for the canine glioma patient showed a decrease in mean dose (>16%) to OARs while increasing the PTV mean dose by up to 15%. Lowering beam energy enhanced PTV dose homogeneity and reduced OAR maximum doses. Significance. The presented work demonstrates that pencil beam scanning SFRT with VHEEs could treat deep-seated tumors such as head and neck cancer or lung lesions, though small beam size and leakage dose may limit the achievable PVDR.


  • Open Access

    Active dosimetry for VHEE FLASH radiotherapy using beam profile monitors and charge measurements

    by Vilde F. Rieker, Roberto Corsini, Steinar Stapnes, Erik Adli, Wilfrid Farabolini, Veljko Grilj, Kyrre N. Sjobak, Laurence M. Wroe, Avni Aksoy, Cameron S. Robertson, et al.


  • Open Access

    Development of a novel fibre optic beam profile and dose monitor for very high energy electron radiotherapy at ultrahigh dose rates

    by Joseph J Bateman, Emma Buchanan, Roberto Corsini, Wilfrid Farabolini, Pierre Korysko, Robert Garbrecht Larsen, Alexander Malyzhenkov, Iñaki Ortega Ruiz, Vilde Rieker, Alexander Gerbershagen, et al.

    Objective. Very high energy electrons (VHEE) in the range of 50–250 MeV are of interest for treating deep-seated tumours with FLASH radiotherapy (RT). This approach offers favourable dose distributions and the ability to deliver ultra-high dose rates (UHDR) efficiently. To make VHEE-based FLASH treatment clinically viable, a novel beam monitoring technology is explored as an alternative to transmission ionisation monitor chambers, which have non-linear responses at UHDR. This study introduces the fibre optic flash monitor (FOFM), which consists of an array of silica optical fibre-based Cherenkov sensors with a photodetector for signal readout. Approach. Experiments were conducted at the CLEAR facility at CERN using 200 MeV and 160 MeV electrons to assess the FOFM’s response linearity to UHDR (characterised with radiochromic films) required for FLASH radiotherapy. Beam profile measurements made on the FOFM were compared to those using radiochromic film and scintillating yttrium aluminium garnet (YAG) screens. Main results. A range of photodetectors were evaluated, with a complementary-metal-oxide-semiconductor (CMOS) camera being the most suitable choice for this monitor. The FOFM demonstrated excellent response linearity from 0.9 Gy/pulse to 57.4 Gy/pulse (R 2 = 0.999). Furthermore, it did not exhibit any significant dependence on the energy between 160 MeV and 200 MeV nor the instantaneous dose rate. Gaussian fits applied to vertical beam profile measurements indicated that the FOFM could accurately provide pulse-by-pulse beam size measurements, agreeing within the error range of radiochromic film and YAG screen measurements, respectively. Significance. The FOFM proves to be a promising solution for real-time beam profile and dose monitoring for UHDR VHEE beams, with a linear response in the UHDR regime. Additionally it can perform pulse-by-pulse beam size measurements, a feature currently lacking in transmission ionisation monitor chambers, which may become crucial for implementing FLASH radiotherapy and its associated quality assurance requirements.


  • Open Access

    Mini-GRID radiotherapy on the CLEAR very-high-energy electron beamline: collimator optimization, film dosimetry, and Monte Carlo simulations

    by Nathan Clements, Nolan Esplen, Joseph Bateman, Cameron Robertson, Manjit Dosanjh, Pierre Korysko, Wilfrid Farabolini, Roberto Corsini, Magdalena Bazalova-Carter

    Objective. Spatially-fractionated radiotherapy (SFRT) delivered with a very-high-energy electron (VHEE) beam and a mini-GRID collimator was investigated to achieve synergistic normal tissue-sparing through spatial fractionation and the FLASH effect. Approach. A tungsten mini-GRID collimator for delivering VHEE SFRT was optimized using Monte Carlo (MC) simulations. Peak-to-valley dose ratios (PVDRs), depths of convergence (DoCs, PVDR ≤ 1.1), and peak and valley doses in a water phantom from a simulated 150 MeV VHEE source were evaluated. Collimator thickness, hole width, and septal width were varied to determine an optimal value for each parameter that maximized PVDR and DoC. The optimized collimator (20 mm thick rectangular prism with a 15 mm × 15 mm face with a 7 × 7 array of 0.5 mm holes separated by 1.1 mm septa) was 3D-printed and used for VHEE irradiations with the CERN linear electron accelerator for research beam. Open beam and mini-GRID irradiations were performed at 140, 175, and 200 MeV and dose was recorded with radiochromic films in a water tank. PVDR, central-axis (CAX) and valley dose rates and DoCs were evaluated. Main results. Films demonstrated peak and valley dose rates on the order of 100 s of MGy/s, which could promote FLASH-sparing effects. Across the three energies, PVDRs of 2–4 at 13 mm depth and DoCs between 39 and 47 mm were achieved. Open beam and mini-GRID MC simulations were run to replicate the film results at 200 MeV. For the mini-GRID irradiations, the film CAX dose was on average 15% higher, the film valley dose was 28% higher, and the film PVDR was 15% lower than calculated by MC. Significance. Ultimately, the PVDRs and DoCs were determined to be too low for a significant potential for SFRT tissue-sparing effects to be present, particularly at depth. Further beam delivery optimization and investigations of new means of spatial fractionation are warranted.


  • Plastic Scintillator Dosimetry of Ultrahigh Dose-Rate 200 MeV Electrons at CLEAR

    by Alexander Hart, Cloé Giguère, Joseph Bateman, Pierre Korysko, Wilfrid Farabolini, Vilde Rieker, Nolan Esplen, Roberto Corsini, Manjit Dosanjh, Luc Beaulieu, et al.

    Very high energy electron (VHEE) beams with energies greater than 100 MeV may be promising candidates for FLASH radiotherapy due to their favourable dose distributions and accessibility of ultrahigh dose-rates (UHDR). Combining VHEE with the normal tissue-sparing FLASH effect of UHDR radiotherapy could improve patient outcomes. The standard dosimeters used for conventional radiotherapy, including ionization chambers and film, have limited application to UHDR radiotherapy due to deficits in dose rate independence and temporal resolution. Plastic scintillator detectors (PSDs) are a potential alternative. PSDs connected to a Medscint Hyperscint RP-100 were used to measure the response to 200 MeV electrons produced by the CERN Linear Electron Accelerator for Research (CLEAR). The dose-response linearity and radiation hardness of PSDs under UHDR VHEE conditions was investigated, using dose rates up to 1.21 × 10 9 Gy/s. Two scintillators were investigated: a polystyrene-based BCF-12 and a proprietary polyvinyltoluene (PVT)-based material. The BCF-12 probe exhibited linear light output with dose per train from 4.9 to 125.2 Gy, and dose rates up to 1.16 × 10 9 Gy/s within a single pulse. The output of the PVT-based probe was linear from 3.9 to 59.5 Gy per train, and dose rates up to 9.92 × 10 8 Gy/s. While output linearity was retained (R 2 > 0.998) after delivering 26.2 and 13.8 kGy to the BCF-12 and PVT-based probe, respectively, the light output was reduced by < 1.5%/kGy. The performance of PSDs in this work suggest they may be useful real-time dosimeters for applications in UHDR VHEE radiotherapy.